Home > Research > Publications & Outputs > Gamma-ray modulation properties of tungsten cod...

Electronic data

  • AAManuscript

    Rights statement: This is an author-created, un-copyedited version of an article accepted for publication/published in Journal of Instrumentation. IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from it. The Version of Record is available online at doi:10.1088/1748-0221/14/02/P02007

    Accepted author manuscript, 1.37 MB, PDF document

    Available under license: CC BY

Links

Text available via DOI:

View graph of relations

Gamma-ray modulation properties of tungsten coded apertures for a novel mixed-field imaging system

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Published
Close
Article numberP02007
<mark>Journal publication date</mark>8/02/2019
<mark>Journal</mark>Journal of Instrumentation
Volume14
Number of pages15
Publication StatusPublished
<mark>Original language</mark>English

Abstract

An investigation into the gamma-ray modulation properties of a tungsten coded aperture, whose design is based on the mathematical principles of Modified Uniformly Redundant Arrays (MURA), has been performed. Due to the small size of the individual cells, the aperture was built using additive manufacturing methods. The gamma-ray field was produced by a 137-Cs radioactive isotope at Lancaster University, UK. An organic plastic scintillator sample, which is capable of pulse shape discrimination, has been used to detect the gamma-ray field modulated by a tungsten aperture. Prior to the investigation of the aperture modulation properties, energy calibration of the scintillator was performed. Its pulse shape discrimination capabilities were verified using a 252-Cf fission source. In this study, each of 169 coded aperture cells were investigated by collimating the modulated gamma-ray field of 137-Cs through a 25.4 mm thick lead supporting plate. The supporting plate has one opening in the centre, of the same dimensions as the single aperture cell, i.e. 2.5 mm by 2.5 mm. The number of pulses detected for every aperture location were recorded in an array. The array was subsequently used to create a two-dimensional image of the source, which was encoded through the coded aperture pattern. Finally, the image was decoded using deconvolution techniques to reveal the actual source location. The new results obtained in this study indicate that sufficient gamma-ray modulation properties of the aperture can be determined, despite the relatively small footprint and thickness of the coded aperture.

Bibliographic note

This is an author-created, un-copyedited version of an article accepted for publication/published in Journal of Instrumentation. IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from it. The Version of Record is available online at doi:10.1088/1748-0221/14/02/P02007