12,000

We have over 12,000 students, from over 100 countries, within one of the safest campuses in the UK

93%

93% of Lancaster students go into work or further study within six months of graduating

Home > Research > Publications & Outputs > A 4-channel Multiplex Analyzer for Real-time, P...
View graph of relations

« Back

A 4-channel Multiplex Analyzer for Real-time, Parallel Processing of Fast Scintillators

Research output: Contribution to conferenceConference paper

Published

Publication date10/2012
Number of pages5
Pages134-138
Original languageEnglish

Conference

Conference2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC)
CountryUnited States
CityAnaheim, Calif.
Period29/10/123/11/12

Abstract

The design, principle of operation and the results of the first measurements made with a 4-channel multiplexed analyzer for real-time parallel processing of fast scintillation detectors is described. Recent advancements in the performance
of organic scintillation media for the detection of fast neutrons, not least the reduction in hazard and the recent advent of plastic scintillation materials exhibiting Pulse Shape Discrimination (PSD), has highlighted the possibility of using multiple detectors in systems based on detectors exploiting these media. In this paper a real-time, digital multiple-channel PSD analyzer is described based on a single-board solution with an integrated high-voltage supply and graphical user interface. It has been developed to meet the requirements of nuclear materials assay of relevance to safeguards and security, and tested in a variety of related laboratory-based environments.