Home > Research > Publications & Outputs > A preliminary hip joint simulator study of the ...
View graph of relations

A preliminary hip joint simulator study of the migration of a cemented femoral stem

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Published

Standard

A preliminary hip joint simulator study of the migration of a cemented femoral stem. / Liu, C.; Green, S. M.; Watkins, N. D. et al.
In: Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, Vol. 217, No. 2, 02.2003, p. 127-135.

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Harvard

Liu, C, Green, SM, Watkins, ND, Gregg, PJ & McCaskie, AW 2003, 'A preliminary hip joint simulator study of the migration of a cemented femoral stem', Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, vol. 217, no. 2, pp. 127-135. https://doi.org/10.1243/09544110360579349

APA

Liu, C., Green, S. M., Watkins, N. D., Gregg, P. J., & McCaskie, A. W. (2003). A preliminary hip joint simulator study of the migration of a cemented femoral stem. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 217(2), 127-135. https://doi.org/10.1243/09544110360579349

Vancouver

Liu C, Green SM, Watkins ND, Gregg PJ, McCaskie AW. A preliminary hip joint simulator study of the migration of a cemented femoral stem. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 2003 Feb;217(2):127-135. doi: 10.1243/09544110360579349

Author

Liu, C. ; Green, S. M. ; Watkins, N. D. et al. / A preliminary hip joint simulator study of the migration of a cemented femoral stem. In: Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 2003 ; Vol. 217, No. 2. pp. 127-135.

Bibtex

@article{a29d7b900b794c7383599596a829b451,
title = "A preliminary hip joint simulator study of the migration of a cemented femoral stem",
abstract = "A hip joint simulator that can be used to evaluate the outcome of the cemented total hip replacement has been designed, manufactured and evaluated. The simulator produces motion of a cemented hip construct in the extension/flexion plane, with a socket to rotate internal/externally. At the same time a dynamic loading cycle is applied to the construct. A validation test was performed on a cemented femoral stem within a novel composite femur. The study demonstrates the value of using a hip joint simulator to evaluate the outcome of the cemented hip construct. A complex migration pattern of the cemented hip prosthesis with respect to load cycling was observed, demonstrated in vitro comparable prosthesis migration behaviour, both the stem migration and migration patterns, to that found clinically.",
keywords = "hip joint simulator, loosening , stem migration , total hip replacement",
author = "C. Liu and Green, {S. M.} and Watkins, {N. D.} and Gregg, {P. J.} and McCaskie, {A. W.}",
year = "2003",
month = feb,
doi = "10.1243/09544110360579349",
language = "English",
volume = "217",
pages = "127--135",
journal = "Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine",
issn = "0954-4119",
publisher = "SAGE Publications Ltd",
number = "2",

}

RIS

TY - JOUR

T1 - A preliminary hip joint simulator study of the migration of a cemented femoral stem

AU - Liu, C.

AU - Green, S. M.

AU - Watkins, N. D.

AU - Gregg, P. J.

AU - McCaskie, A. W.

PY - 2003/2

Y1 - 2003/2

N2 - A hip joint simulator that can be used to evaluate the outcome of the cemented total hip replacement has been designed, manufactured and evaluated. The simulator produces motion of a cemented hip construct in the extension/flexion plane, with a socket to rotate internal/externally. At the same time a dynamic loading cycle is applied to the construct. A validation test was performed on a cemented femoral stem within a novel composite femur. The study demonstrates the value of using a hip joint simulator to evaluate the outcome of the cemented hip construct. A complex migration pattern of the cemented hip prosthesis with respect to load cycling was observed, demonstrated in vitro comparable prosthesis migration behaviour, both the stem migration and migration patterns, to that found clinically.

AB - A hip joint simulator that can be used to evaluate the outcome of the cemented total hip replacement has been designed, manufactured and evaluated. The simulator produces motion of a cemented hip construct in the extension/flexion plane, with a socket to rotate internal/externally. At the same time a dynamic loading cycle is applied to the construct. A validation test was performed on a cemented femoral stem within a novel composite femur. The study demonstrates the value of using a hip joint simulator to evaluate the outcome of the cemented hip construct. A complex migration pattern of the cemented hip prosthesis with respect to load cycling was observed, demonstrated in vitro comparable prosthesis migration behaviour, both the stem migration and migration patterns, to that found clinically.

KW - hip joint simulator

KW - loosening

KW - stem migration

KW - total hip replacement

U2 - 10.1243/09544110360579349

DO - 10.1243/09544110360579349

M3 - Journal article

VL - 217

SP - 127

EP - 135

JO - Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine

JF - Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine

SN - 0954-4119

IS - 2

ER -