Home > Research > Publications & Outputs > A thalium-doped sodium iodide well counter for ...
View graph of relations

A thalium-doped sodium iodide well counter for radioactive tracer applications with naturally-abundant 40K

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Published

Standard

A thalium-doped sodium iodide well counter for radioactive tracer applications with naturally-abundant 40K. / Parker, Andrew; Boxall, Colin; Joyce, Malcolm et al.
In: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 722, 11.09.2013, p. 5-10.

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Harvard

Parker, A, Boxall, C, Joyce, M & Schotanus, P 2013, 'A thalium-doped sodium iodide well counter for radioactive tracer applications with naturally-abundant 40K', Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, vol. 722, pp. 5-10. https://doi.org/10.1016/j.nima.2013.04.034

APA

Parker, A., Boxall, C., Joyce, M., & Schotanus, P. (2013). A thalium-doped sodium iodide well counter for radioactive tracer applications with naturally-abundant 40K. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 722, 5-10. https://doi.org/10.1016/j.nima.2013.04.034

Vancouver

Parker A, Boxall C, Joyce M, Schotanus P. A thalium-doped sodium iodide well counter for radioactive tracer applications with naturally-abundant 40K. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 2013 Sept 11;722:5-10. doi: 10.1016/j.nima.2013.04.034

Author

Parker, Andrew ; Boxall, Colin ; Joyce, Malcolm et al. / A thalium-doped sodium iodide well counter for radioactive tracer applications with naturally-abundant 40K. In: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 2013 ; Vol. 722. pp. 5-10.

Bibtex

@article{dfa44470bcf54ffb9075f1c2029dbbb8,
title = "A thalium-doped sodium iodide well counter for radioactive tracer applications with naturally-abundant 40K",
abstract = "The use of a thallium-doped sodium-iodide well-type scintillation detector for the assay of the low-activity radioisotope 40K, in open-source potassium chloride aqueous solutions, is described. The hazards, safety concerns and radiowaste generation associated with using open-source radioactive isotopes can present significant difficulties, the use of hot cells and escalated costs in radioanalytical laboratory research. A solution to this is the use of low-hazard alternatives that mimic the migration and dispersion characteristics of notable fission products (in this case 137Cs). The use of NaI(Tl) as a detection medium for naturally-abundant levels of 40K in a range of media is widespread, but the use of 40K as a radioactive tracer has not been reported. The use of such low-activity sources is often complicated by the ability to detect them efficiently. In this paper a scintillator detector designed to detect the naturally-abundant 40K present in potassium chloride in tracer applications is described. Examples of the use of potassium chloride as a tracer are given in the context of ion exchange and electrochemical migration studies, and comparisons in performance are drawn from literature with hyper pure germanium semiconductor detectors, which are more commonly utilised detectors in high-resolution counting applications.",
keywords = "Sodium iodide well-counter, Potassium 40 , Non-hazardous radioactive tracer , Low-activity counting",
author = "Andrew Parker and Colin Boxall and Malcolm Joyce and Paul Schotanus",
year = "2013",
month = sep,
day = "11",
doi = "10.1016/j.nima.2013.04.034",
language = "English",
volume = "722",
pages = "5--10",
journal = "Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment",
issn = "0168-9002",
publisher = "ELSEVIER SCIENCE BV",

}

RIS

TY - JOUR

T1 - A thalium-doped sodium iodide well counter for radioactive tracer applications with naturally-abundant 40K

AU - Parker, Andrew

AU - Boxall, Colin

AU - Joyce, Malcolm

AU - Schotanus, Paul

PY - 2013/9/11

Y1 - 2013/9/11

N2 - The use of a thallium-doped sodium-iodide well-type scintillation detector for the assay of the low-activity radioisotope 40K, in open-source potassium chloride aqueous solutions, is described. The hazards, safety concerns and radiowaste generation associated with using open-source radioactive isotopes can present significant difficulties, the use of hot cells and escalated costs in radioanalytical laboratory research. A solution to this is the use of low-hazard alternatives that mimic the migration and dispersion characteristics of notable fission products (in this case 137Cs). The use of NaI(Tl) as a detection medium for naturally-abundant levels of 40K in a range of media is widespread, but the use of 40K as a radioactive tracer has not been reported. The use of such low-activity sources is often complicated by the ability to detect them efficiently. In this paper a scintillator detector designed to detect the naturally-abundant 40K present in potassium chloride in tracer applications is described. Examples of the use of potassium chloride as a tracer are given in the context of ion exchange and electrochemical migration studies, and comparisons in performance are drawn from literature with hyper pure germanium semiconductor detectors, which are more commonly utilised detectors in high-resolution counting applications.

AB - The use of a thallium-doped sodium-iodide well-type scintillation detector for the assay of the low-activity radioisotope 40K, in open-source potassium chloride aqueous solutions, is described. The hazards, safety concerns and radiowaste generation associated with using open-source radioactive isotopes can present significant difficulties, the use of hot cells and escalated costs in radioanalytical laboratory research. A solution to this is the use of low-hazard alternatives that mimic the migration and dispersion characteristics of notable fission products (in this case 137Cs). The use of NaI(Tl) as a detection medium for naturally-abundant levels of 40K in a range of media is widespread, but the use of 40K as a radioactive tracer has not been reported. The use of such low-activity sources is often complicated by the ability to detect them efficiently. In this paper a scintillator detector designed to detect the naturally-abundant 40K present in potassium chloride in tracer applications is described. Examples of the use of potassium chloride as a tracer are given in the context of ion exchange and electrochemical migration studies, and comparisons in performance are drawn from literature with hyper pure germanium semiconductor detectors, which are more commonly utilised detectors in high-resolution counting applications.

KW - Sodium iodide well-counter

KW - Potassium 40

KW - Non-hazardous radioactive tracer

KW - Low-activity counting

U2 - 10.1016/j.nima.2013.04.034

DO - 10.1016/j.nima.2013.04.034

M3 - Journal article

VL - 722

SP - 5

EP - 10

JO - Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

JF - Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

SN - 0168-9002

ER -