Home > Research > Publications & Outputs > Attenuated total reflection Fourier-transform i...

Links

Text available via DOI:

View graph of relations

Attenuated total reflection Fourier-transform infrared (ATR-FTIR) spectroscopy to diagnose osteoarthritis in equine serum

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Published

Standard

Attenuated total reflection Fourier-transform infrared (ATR-FTIR) spectroscopy to diagnose osteoarthritis in equine serum. / Paraskevaidi, M.; Hook, P.D.; Morais, C.L.M. et al.
In: Equine Veterinary Journal, Vol. 52, No. 1, 31.01.2020, p. 46-51.

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Harvard

Paraskevaidi, M, Hook, PD, Morais, CLM, Anderson, JR, White, R, Martin-Hirsch, PL, Peffers, MJ & Martin, FL 2020, 'Attenuated total reflection Fourier-transform infrared (ATR-FTIR) spectroscopy to diagnose osteoarthritis in equine serum', Equine Veterinary Journal, vol. 52, no. 1, pp. 46-51. https://doi.org/10.1111/evj.13115

APA

Paraskevaidi, M., Hook, P. D., Morais, C. L. M., Anderson, J. R., White, R., Martin-Hirsch, P. L., Peffers, M. J., & Martin, F. L. (2020). Attenuated total reflection Fourier-transform infrared (ATR-FTIR) spectroscopy to diagnose osteoarthritis in equine serum. Equine Veterinary Journal, 52(1), 46-51. https://doi.org/10.1111/evj.13115

Vancouver

Paraskevaidi M, Hook PD, Morais CLM, Anderson JR, White R, Martin-Hirsch PL et al. Attenuated total reflection Fourier-transform infrared (ATR-FTIR) spectroscopy to diagnose osteoarthritis in equine serum. Equine Veterinary Journal. 2020 Jan 31;52(1):46-51. Epub 2019 Apr 17. doi: 10.1111/evj.13115

Author

Paraskevaidi, M. ; Hook, P.D. ; Morais, C.L.M. et al. / Attenuated total reflection Fourier-transform infrared (ATR-FTIR) spectroscopy to diagnose osteoarthritis in equine serum. In: Equine Veterinary Journal. 2020 ; Vol. 52, No. 1. pp. 46-51.

Bibtex

@article{0d9483a41fb34d4c9846a33fc138eac1,
title = "Attenuated total reflection Fourier-transform infrared (ATR-FTIR) spectroscopy to diagnose osteoarthritis in equine serum",
abstract = "Background: Reliable and validated biomarkers for osteoarthritis (OA) are currently lacking. Objectives: To develop an accurate and minimally invasive method to assess OA-affected horses and provide potential spectral markers indicative of disease. Study design: Observational, cross-sectional study. Methods: Our cohort consisted of 15 horses with OA and 48 without clinical signs of the disease, which were used as controls. Attenuated total reflection Fourier-transform infrared (ATR-FTIR) spectroscopy was used to investigate serum samples (50 μL) collected from these horses. Spectral processing and multivariate analysis revealed differences and similarities, allowing for detection of spectral biomarkers that discriminated between the two cohorts. A supervised classification algorithm, namely principal component analysis coupled with quadratic discriminant analysis (PCA-QDA), was applied to evaluate the diagnostic accuracy. Results: Segregation between the two different cohorts, OA-affected and controls, was achieved with 100% sensitivity and specificity. The six most discriminatory peaks were attributed to proteins and lipids. Four of the spectral peaks were elevated in OA horses, which could be potentially due to an increase in lipids, protein expression levels and collagen, all of which have been previously reported in OA. Two peaks were found decreased and were tentatively assigned to the reduction of proteoglycan content that is observed during OA. Main limitations: The control group had a wide range of ages and breeds. Presymptomatic OA cases were not included. Therefore, it remains unknown whether this test could also be used as an early diagnostic tool. Conclusions: This spectrochemical approach could provide an accurate and cost-effective blood test, facilitating point-of-care diagnosis of equine OA. ",
keywords = "biomarkers, horse, horse osteoarthritis, infrared spectroscopy, point-of-care testing, serum diagnostics",
author = "M. Paraskevaidi and P.D. Hook and C.L.M. Morais and J.R. Anderson and R. White and P.L. Martin-Hirsch and M.J. Peffers and F.L. Martin",
year = "2020",
month = jan,
day = "31",
doi = "10.1111/evj.13115",
language = "English",
volume = "52",
pages = "46--51",
journal = "Equine Veterinary Journal",
issn = "0425-1644",
publisher = "Equine Veterinary Journal Ltd.",
number = "1",

}

RIS

TY - JOUR

T1 - Attenuated total reflection Fourier-transform infrared (ATR-FTIR) spectroscopy to diagnose osteoarthritis in equine serum

AU - Paraskevaidi, M.

AU - Hook, P.D.

AU - Morais, C.L.M.

AU - Anderson, J.R.

AU - White, R.

AU - Martin-Hirsch, P.L.

AU - Peffers, M.J.

AU - Martin, F.L.

PY - 2020/1/31

Y1 - 2020/1/31

N2 - Background: Reliable and validated biomarkers for osteoarthritis (OA) are currently lacking. Objectives: To develop an accurate and minimally invasive method to assess OA-affected horses and provide potential spectral markers indicative of disease. Study design: Observational, cross-sectional study. Methods: Our cohort consisted of 15 horses with OA and 48 without clinical signs of the disease, which were used as controls. Attenuated total reflection Fourier-transform infrared (ATR-FTIR) spectroscopy was used to investigate serum samples (50 μL) collected from these horses. Spectral processing and multivariate analysis revealed differences and similarities, allowing for detection of spectral biomarkers that discriminated between the two cohorts. A supervised classification algorithm, namely principal component analysis coupled with quadratic discriminant analysis (PCA-QDA), was applied to evaluate the diagnostic accuracy. Results: Segregation between the two different cohorts, OA-affected and controls, was achieved with 100% sensitivity and specificity. The six most discriminatory peaks were attributed to proteins and lipids. Four of the spectral peaks were elevated in OA horses, which could be potentially due to an increase in lipids, protein expression levels and collagen, all of which have been previously reported in OA. Two peaks were found decreased and were tentatively assigned to the reduction of proteoglycan content that is observed during OA. Main limitations: The control group had a wide range of ages and breeds. Presymptomatic OA cases were not included. Therefore, it remains unknown whether this test could also be used as an early diagnostic tool. Conclusions: This spectrochemical approach could provide an accurate and cost-effective blood test, facilitating point-of-care diagnosis of equine OA.

AB - Background: Reliable and validated biomarkers for osteoarthritis (OA) are currently lacking. Objectives: To develop an accurate and minimally invasive method to assess OA-affected horses and provide potential spectral markers indicative of disease. Study design: Observational, cross-sectional study. Methods: Our cohort consisted of 15 horses with OA and 48 without clinical signs of the disease, which were used as controls. Attenuated total reflection Fourier-transform infrared (ATR-FTIR) spectroscopy was used to investigate serum samples (50 μL) collected from these horses. Spectral processing and multivariate analysis revealed differences and similarities, allowing for detection of spectral biomarkers that discriminated between the two cohorts. A supervised classification algorithm, namely principal component analysis coupled with quadratic discriminant analysis (PCA-QDA), was applied to evaluate the diagnostic accuracy. Results: Segregation between the two different cohorts, OA-affected and controls, was achieved with 100% sensitivity and specificity. The six most discriminatory peaks were attributed to proteins and lipids. Four of the spectral peaks were elevated in OA horses, which could be potentially due to an increase in lipids, protein expression levels and collagen, all of which have been previously reported in OA. Two peaks were found decreased and were tentatively assigned to the reduction of proteoglycan content that is observed during OA. Main limitations: The control group had a wide range of ages and breeds. Presymptomatic OA cases were not included. Therefore, it remains unknown whether this test could also be used as an early diagnostic tool. Conclusions: This spectrochemical approach could provide an accurate and cost-effective blood test, facilitating point-of-care diagnosis of equine OA.

KW - biomarkers

KW - horse

KW - horse osteoarthritis

KW - infrared spectroscopy

KW - point-of-care testing

KW - serum diagnostics

U2 - 10.1111/evj.13115

DO - 10.1111/evj.13115

M3 - Journal article

VL - 52

SP - 46

EP - 51

JO - Equine Veterinary Journal

JF - Equine Veterinary Journal

SN - 0425-1644

IS - 1

ER -