Home > Research > Publications & Outputs > Automated Response Matching for Organic Scintil...

Electronic data

  • 1-s2.0-S0168900217305338-main

    Rights statement: This is the author’s version of a work that was accepted for publication in Physics Reports. Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. Changes may have been made to this work since it was submitted for publication. A definitive version was subsequently published in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 861, 2017 DOI: 10.1016/j.nima.2017.05.004

    Accepted author manuscript, 691 KB, PDF document

    Available under license: CC BY-NC-ND: Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License

Links

Text available via DOI:

View graph of relations

Automated Response Matching for Organic Scintillation Detector Arrays

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Published
<mark>Journal publication date</mark>21/07/2017
<mark>Journal</mark>Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Volume861
Number of pages9
Pages (from-to)46-54
Publication StatusPublished
Early online date5/05/17
<mark>Original language</mark>English

Abstract

This paper identifies a digitizer technology with unique features that facilitates feedback control for the realization of a software-based technique for automatically calibrating detector responses. Three such auto-calibration techniques have been developed and are described along with an explanation of the main configuration settings and potential pitfalls. Automating this process increases repeatability, simplifies user operation, enables remote and periodic system calibration where consistency across detectors’ responses are critical.

Bibliographic note

This is the author’s version of a work that was accepted for publication in Physics Reports. Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. Changes may have been made to this work since it was submitted for publication. A definitive version was subsequently published in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 861, 2017 DOI: 10.1016/j.nima.2017.05.004