Home > Research > Publications & Outputs > Carrier dynamics and resolution of co-planar gr...

Text available via DOI:

View graph of relations

Carrier dynamics and resolution of co-planar grid radiation detectors

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Published

Standard

Carrier dynamics and resolution of co-planar grid radiation detectors. / Kozorezov, A. G.; Owens, A.; Peacock, A. et al.
In: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 563, No. 1, 07.2006, p. 37-40.

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Harvard

Kozorezov, AG, Owens, A, Peacock, A & Wigmore, JK 2006, 'Carrier dynamics and resolution of co-planar grid radiation detectors', Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, vol. 563, no. 1, pp. 37-40. https://doi.org/10.1016/j.nima.2006.01.062

APA

Kozorezov, A. G., Owens, A., Peacock, A., & Wigmore, J. K. (2006). Carrier dynamics and resolution of co-planar grid radiation detectors. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 563(1), 37-40. https://doi.org/10.1016/j.nima.2006.01.062

Vancouver

Kozorezov AG, Owens A, Peacock A, Wigmore JK. Carrier dynamics and resolution of co-planar grid radiation detectors. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 2006 Jul;563(1):37-40. doi: 10.1016/j.nima.2006.01.062

Author

Kozorezov, A. G. ; Owens, A. ; Peacock, A. et al. / Carrier dynamics and resolution of co-planar grid radiation detectors. In: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 2006 ; Vol. 563, No. 1. pp. 37-40.

Bibtex

@article{6e15cc6734244f32a20f57bff1659246,
title = "Carrier dynamics and resolution of co-planar grid radiation detectors",
abstract = "Co-planar grid detectors utilizing single carrier sensing techniques, offer a practical solution for developing compound semiconductor gamma-ray detectors with high resolving power. We present an analytical model for describing the response of co-planar grid detector. The response of a co-planar grid detector is shown to be affected by intrinsic lateral inhomogeneity, which is inherent to its design. We evaluate the effect of both lateral and bulk inhomogeneities and show that the resolution of a co-planar grid detector is dominated by inhomogeneous broadening of the signal and not by Fano or electronic noise.",
keywords = "Co-planar grid detector, Carrier's drift trajectories, Inhomogeneous broadening",
author = "Kozorezov, {A. G.} and A. Owens and A. Peacock and Wigmore, {J. K.}",
year = "2006",
month = jul,
doi = "10.1016/j.nima.2006.01.062",
language = "English",
volume = "563",
pages = "37--40",
journal = "Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment",
publisher = "ELSEVIER SCIENCE BV",
number = "1",

}

RIS

TY - JOUR

T1 - Carrier dynamics and resolution of co-planar grid radiation detectors

AU - Kozorezov, A. G.

AU - Owens, A.

AU - Peacock, A.

AU - Wigmore, J. K.

PY - 2006/7

Y1 - 2006/7

N2 - Co-planar grid detectors utilizing single carrier sensing techniques, offer a practical solution for developing compound semiconductor gamma-ray detectors with high resolving power. We present an analytical model for describing the response of co-planar grid detector. The response of a co-planar grid detector is shown to be affected by intrinsic lateral inhomogeneity, which is inherent to its design. We evaluate the effect of both lateral and bulk inhomogeneities and show that the resolution of a co-planar grid detector is dominated by inhomogeneous broadening of the signal and not by Fano or electronic noise.

AB - Co-planar grid detectors utilizing single carrier sensing techniques, offer a practical solution for developing compound semiconductor gamma-ray detectors with high resolving power. We present an analytical model for describing the response of co-planar grid detector. The response of a co-planar grid detector is shown to be affected by intrinsic lateral inhomogeneity, which is inherent to its design. We evaluate the effect of both lateral and bulk inhomogeneities and show that the resolution of a co-planar grid detector is dominated by inhomogeneous broadening of the signal and not by Fano or electronic noise.

KW - Co-planar grid detector

KW - Carrier's drift trajectories

KW - Inhomogeneous broadening

U2 - 10.1016/j.nima.2006.01.062

DO - 10.1016/j.nima.2006.01.062

M3 - Journal article

VL - 563

SP - 37

EP - 40

JO - Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

JF - Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

IS - 1

ER -