Home > Research > Publications & Outputs > Continuous Monitoring of PCDD/Fs in the UK Atmo...

Links

Text available via DOI:

View graph of relations

Continuous Monitoring of PCDD/Fs in the UK Atmosphere : 1991-2008.

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Published

Standard

Continuous Monitoring of PCDD/Fs in the UK Atmosphere : 1991-2008. / Katsogiannis, Athanasios; Gioia, Rosalinda; Sweetman, Andrew J. et al.
In: Environmental Science and Technology, Vol. 44, No. 15, 01.08.2010, p. 5735-5740.

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Harvard

Katsogiannis, A, Gioia, R, Sweetman, AJ & Jones, KC 2010, 'Continuous Monitoring of PCDD/Fs in the UK Atmosphere : 1991-2008.', Environmental Science and Technology, vol. 44, no. 15, pp. 5735-5740. https://doi.org/10.1021/es1009828

APA

Vancouver

Katsogiannis A, Gioia R, Sweetman AJ, Jones KC. Continuous Monitoring of PCDD/Fs in the UK Atmosphere : 1991-2008. Environmental Science and Technology. 2010 Aug 1;44(15):5735-5740. doi: 10.1021/es1009828

Author

Katsogiannis, Athanasios ; Gioia, Rosalinda ; Sweetman, Andrew J. et al. / Continuous Monitoring of PCDD/Fs in the UK Atmosphere : 1991-2008. In: Environmental Science and Technology. 2010 ; Vol. 44, No. 15. pp. 5735-5740.

Bibtex

@article{9d054d90973a414cbbb6e6eb17ece039,
title = "Continuous Monitoring of PCDD/Fs in the UK Atmosphere : 1991-2008.",
abstract = "This study summarizes the key findings of a long-term (1991−2008) monitoring program to measure polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in urban and rural ambient air in the UK. Air concentrations are reported for 6 sites—3 urban (London, Manchester, and Middlesbrough) and 3 rural/semirural (Hazelrigg, High Muffles, and Stoke Ferry). Nearly 310 samples have been analyzed, each for a 3-month period. Annually averaged urban concentrations in the early 1990s were typically a few 100s fg (TEQ) m−3 and <50 fg m−3 in the mid-2000s. Applying first-order kinetics to the whole urban time series gave T1/2 (atmospheric half-lives) in London and Manchester of 3.2−5.9 and 4.1−5.9 years, respectively. Estimated national annual atmospheric emissions trends broadly correlated with the trends in urban ambient concentrations, suggesting that the inventory has captured the broad mixture of sources. However, rural air concentrations (in the low 10s fg m−3) show no discernible change since 1996, while recent urban concentrations are close to those in rural areas. Other UK trend data infer the declines in the 1990s followed previous declines in the 1980s from peak levels in the 1950−1970s, all before routine monitoring began. Winter concentrations are generally a factor of 2−3 higher than summer concentrations, implicating diffuse combustion sources (e.g., domestic space heating). These observations taken together suggest that most major readily controllable primary/point sources were reduced by the early/mid-1990s in the UK and that current ambient levels in both rural and urban areas may remain at broadly similar levels in the foreseeable future, unless there are major changes in energy requirements and generation options, fuel usage, and policy drivers.",
author = "Athanasios Katsogiannis and Rosalinda Gioia and Sweetman, {Andrew J.} and Jones, {Kevin C.}",
year = "2010",
month = aug,
day = "1",
doi = "10.1021/es1009828",
language = "English",
volume = "44",
pages = "5735--5740",
journal = "Environmental Science and Technology",
issn = "0013-936X",
publisher = "American Chemical Society",
number = "15",

}

RIS

TY - JOUR

T1 - Continuous Monitoring of PCDD/Fs in the UK Atmosphere : 1991-2008.

AU - Katsogiannis, Athanasios

AU - Gioia, Rosalinda

AU - Sweetman, Andrew J.

AU - Jones, Kevin C.

PY - 2010/8/1

Y1 - 2010/8/1

N2 - This study summarizes the key findings of a long-term (1991−2008) monitoring program to measure polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in urban and rural ambient air in the UK. Air concentrations are reported for 6 sites—3 urban (London, Manchester, and Middlesbrough) and 3 rural/semirural (Hazelrigg, High Muffles, and Stoke Ferry). Nearly 310 samples have been analyzed, each for a 3-month period. Annually averaged urban concentrations in the early 1990s were typically a few 100s fg (TEQ) m−3 and <50 fg m−3 in the mid-2000s. Applying first-order kinetics to the whole urban time series gave T1/2 (atmospheric half-lives) in London and Manchester of 3.2−5.9 and 4.1−5.9 years, respectively. Estimated national annual atmospheric emissions trends broadly correlated with the trends in urban ambient concentrations, suggesting that the inventory has captured the broad mixture of sources. However, rural air concentrations (in the low 10s fg m−3) show no discernible change since 1996, while recent urban concentrations are close to those in rural areas. Other UK trend data infer the declines in the 1990s followed previous declines in the 1980s from peak levels in the 1950−1970s, all before routine monitoring began. Winter concentrations are generally a factor of 2−3 higher than summer concentrations, implicating diffuse combustion sources (e.g., domestic space heating). These observations taken together suggest that most major readily controllable primary/point sources were reduced by the early/mid-1990s in the UK and that current ambient levels in both rural and urban areas may remain at broadly similar levels in the foreseeable future, unless there are major changes in energy requirements and generation options, fuel usage, and policy drivers.

AB - This study summarizes the key findings of a long-term (1991−2008) monitoring program to measure polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in urban and rural ambient air in the UK. Air concentrations are reported for 6 sites—3 urban (London, Manchester, and Middlesbrough) and 3 rural/semirural (Hazelrigg, High Muffles, and Stoke Ferry). Nearly 310 samples have been analyzed, each for a 3-month period. Annually averaged urban concentrations in the early 1990s were typically a few 100s fg (TEQ) m−3 and <50 fg m−3 in the mid-2000s. Applying first-order kinetics to the whole urban time series gave T1/2 (atmospheric half-lives) in London and Manchester of 3.2−5.9 and 4.1−5.9 years, respectively. Estimated national annual atmospheric emissions trends broadly correlated with the trends in urban ambient concentrations, suggesting that the inventory has captured the broad mixture of sources. However, rural air concentrations (in the low 10s fg m−3) show no discernible change since 1996, while recent urban concentrations are close to those in rural areas. Other UK trend data infer the declines in the 1990s followed previous declines in the 1980s from peak levels in the 1950−1970s, all before routine monitoring began. Winter concentrations are generally a factor of 2−3 higher than summer concentrations, implicating diffuse combustion sources (e.g., domestic space heating). These observations taken together suggest that most major readily controllable primary/point sources were reduced by the early/mid-1990s in the UK and that current ambient levels in both rural and urban areas may remain at broadly similar levels in the foreseeable future, unless there are major changes in energy requirements and generation options, fuel usage, and policy drivers.

U2 - 10.1021/es1009828

DO - 10.1021/es1009828

M3 - Journal article

VL - 44

SP - 5735

EP - 5740

JO - Environmental Science and Technology

JF - Environmental Science and Technology

SN - 0013-936X

IS - 15

ER -