Home > Research > Publications & Outputs > Determination of reactive hydrocarbons by capil...
View graph of relations

Determination of reactive hydrocarbons by capillary gas chromatography with the reduction gas detector.

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Published

Standard

Determination of reactive hydrocarbons by capillary gas chromatography with the reduction gas detector. / Cao, Xu-Liang; Hewitt, CN; Waterhouse, K. S.
In: Journal of Chromatography A, Vol. 679, No. 1, 1994, p. 115-121.

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Harvard

APA

Vancouver

Cao X-L, Hewitt CN, Waterhouse KS. Determination of reactive hydrocarbons by capillary gas chromatography with the reduction gas detector. Journal of Chromatography A. 1994;679(1):115-121. doi: 10.1016/0021-9673(94)80317-X

Author

Cao, Xu-Liang ; Hewitt, CN ; Waterhouse, K. S. / Determination of reactive hydrocarbons by capillary gas chromatography with the reduction gas detector. In: Journal of Chromatography A. 1994 ; Vol. 679, No. 1. pp. 115-121.

Bibtex

@article{68cc117bc9f44c9ea4a2a75dbb7300f2,
title = "Determination of reactive hydrocarbons by capillary gas chromatography with the reduction gas detector.",
abstract = "The reduction gas detector has been used successfully for the capillary GC determination of C2---C6 alkenes and isoprene. The detection limits have been improved by using a capillary GC column. The peak shapes for hydrocarbons above C6 (benzene, toluene, p- xylene, o-xylene, α-pinene and β-pinene) are very broad and tailing due to their slow and incomplete reactions with HgO at the maximum temperature (300°C) achievable with the present reduction gas detector. If the HgO bed temperature of the detector could be increased, the system might be applicable to the detection of higher-molecular-mass compounds.",
author = "Xu-Liang Cao and CN Hewitt and Waterhouse, {K. S.}",
year = "1994",
doi = "10.1016/0021-9673(94)80317-X",
language = "English",
volume = "679",
pages = "115--121",
journal = "Journal of Chromatography A",
issn = "1873-3778",
publisher = "Elsevier",
number = "1",

}

RIS

TY - JOUR

T1 - Determination of reactive hydrocarbons by capillary gas chromatography with the reduction gas detector.

AU - Cao, Xu-Liang

AU - Hewitt, CN

AU - Waterhouse, K. S.

PY - 1994

Y1 - 1994

N2 - The reduction gas detector has been used successfully for the capillary GC determination of C2---C6 alkenes and isoprene. The detection limits have been improved by using a capillary GC column. The peak shapes for hydrocarbons above C6 (benzene, toluene, p- xylene, o-xylene, α-pinene and β-pinene) are very broad and tailing due to their slow and incomplete reactions with HgO at the maximum temperature (300°C) achievable with the present reduction gas detector. If the HgO bed temperature of the detector could be increased, the system might be applicable to the detection of higher-molecular-mass compounds.

AB - The reduction gas detector has been used successfully for the capillary GC determination of C2---C6 alkenes and isoprene. The detection limits have been improved by using a capillary GC column. The peak shapes for hydrocarbons above C6 (benzene, toluene, p- xylene, o-xylene, α-pinene and β-pinene) are very broad and tailing due to their slow and incomplete reactions with HgO at the maximum temperature (300°C) achievable with the present reduction gas detector. If the HgO bed temperature of the detector could be increased, the system might be applicable to the detection of higher-molecular-mass compounds.

U2 - 10.1016/0021-9673(94)80317-X

DO - 10.1016/0021-9673(94)80317-X

M3 - Journal article

VL - 679

SP - 115

EP - 121

JO - Journal of Chromatography A

JF - Journal of Chromatography A

SN - 1873-3778

IS - 1

ER -