Home > Research > Publications & Outputs > Evaluation of ultrafiltration and conventional ...

Links

Text available via DOI:

View graph of relations

Evaluation of ultrafiltration and conventional water treatment systems for sustainable development: An industrial scale case study

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Published

Standard

Evaluation of ultrafiltration and conventional water treatment systems for sustainable development: An industrial scale case study. / Chew, Chun Ming; Aroua, Mohamed Kheireddine; Hussain, Mohd Azlan et al.
In: Journal of Cleaner Production, Vol. 112, 20.01.2016, p. 3152-3163.

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Harvard

APA

Vancouver

Chew CM, Aroua MK, Hussain MA, Ismail WMZW. Evaluation of ultrafiltration and conventional water treatment systems for sustainable development: An industrial scale case study. Journal of Cleaner Production. 2016 Jan 20;112:3152-3163. Epub 2015 Oct 19. doi: 10.1016/j.jclepro.2015.10.037

Author

Chew, Chun Ming ; Aroua, Mohamed Kheireddine ; Hussain, Mohd Azlan et al. / Evaluation of ultrafiltration and conventional water treatment systems for sustainable development : An industrial scale case study. In: Journal of Cleaner Production. 2016 ; Vol. 112. pp. 3152-3163.

Bibtex

@article{ec51b28369034186af45c6ae66991a93,
title = "Evaluation of ultrafiltration and conventional water treatment systems for sustainable development: An industrial scale case study",
abstract = "Sustainable developments in water treatment systems are challenges in the 21st century. More industrial-scale drinking water treatment plants are using ultrafiltration (UF) membrane systems. Conventional media filtration is the mainstream treatment process for these plants especially in developing countries. Evaluations of both industrial-scale UF and conventional drinking water treatment systems have been carried out in this study. These treatment systems are evaluated based on 5 aspects which are capital expenditure, operational expenditure, maintenance cost, treated water quality and water losses. A case study water treatment plant in Malaysia which encompassed both the UF and conventional media filtration systems are used to elucidate this comparison study. River water source is fed as surface raw water to both systems. The UF system has exhibited consistent filtrate quality regardless of the fluctuation of raw water quality. Sludge discharged from the UF backwash remains the same characteristics as the feed water except with higher concentration of solids content. However, sludge from the conventional system contains high concentration of Aluminium residual originating from the coagulant. The UF system caused higher water losses compared to the conventional system. As for operation and maintenance expenditures, the conventional systems are more economical. Sensitivity analyses have been carried out on the capital expenditure and operational expenditure. Precaution measures have been taken to ensure all data collected are relevant and accurate. More than 12 months of treatment systems operational data are collected, compiled and analysed to substantiate the results. This study intends to highlight the commercial and environmental sustainability of both systems. The major contribution and novelty of this work is that it provides useful reference to the decision makers and stakeholders on the selection of treatment process for industrial-scale drinking water facilities to accommodate their current and future requirements.",
keywords = "Drinking water, Media filtration, Sustainable development, Ultrafiltration",
author = "Chew, {Chun Ming} and Aroua, {Mohamed Kheireddine} and Hussain, {Mohd Azlan} and Ismail, {Wan Mohd Zamri Wan}",
year = "2016",
month = jan,
day = "20",
doi = "10.1016/j.jclepro.2015.10.037",
language = "English",
volume = "112",
pages = "3152--3163",
journal = "Journal of Cleaner Production",
issn = "0959-6526",
publisher = "Elsevier Ltd",

}

RIS

TY - JOUR

T1 - Evaluation of ultrafiltration and conventional water treatment systems for sustainable development

T2 - An industrial scale case study

AU - Chew, Chun Ming

AU - Aroua, Mohamed Kheireddine

AU - Hussain, Mohd Azlan

AU - Ismail, Wan Mohd Zamri Wan

PY - 2016/1/20

Y1 - 2016/1/20

N2 - Sustainable developments in water treatment systems are challenges in the 21st century. More industrial-scale drinking water treatment plants are using ultrafiltration (UF) membrane systems. Conventional media filtration is the mainstream treatment process for these plants especially in developing countries. Evaluations of both industrial-scale UF and conventional drinking water treatment systems have been carried out in this study. These treatment systems are evaluated based on 5 aspects which are capital expenditure, operational expenditure, maintenance cost, treated water quality and water losses. A case study water treatment plant in Malaysia which encompassed both the UF and conventional media filtration systems are used to elucidate this comparison study. River water source is fed as surface raw water to both systems. The UF system has exhibited consistent filtrate quality regardless of the fluctuation of raw water quality. Sludge discharged from the UF backwash remains the same characteristics as the feed water except with higher concentration of solids content. However, sludge from the conventional system contains high concentration of Aluminium residual originating from the coagulant. The UF system caused higher water losses compared to the conventional system. As for operation and maintenance expenditures, the conventional systems are more economical. Sensitivity analyses have been carried out on the capital expenditure and operational expenditure. Precaution measures have been taken to ensure all data collected are relevant and accurate. More than 12 months of treatment systems operational data are collected, compiled and analysed to substantiate the results. This study intends to highlight the commercial and environmental sustainability of both systems. The major contribution and novelty of this work is that it provides useful reference to the decision makers and stakeholders on the selection of treatment process for industrial-scale drinking water facilities to accommodate their current and future requirements.

AB - Sustainable developments in water treatment systems are challenges in the 21st century. More industrial-scale drinking water treatment plants are using ultrafiltration (UF) membrane systems. Conventional media filtration is the mainstream treatment process for these plants especially in developing countries. Evaluations of both industrial-scale UF and conventional drinking water treatment systems have been carried out in this study. These treatment systems are evaluated based on 5 aspects which are capital expenditure, operational expenditure, maintenance cost, treated water quality and water losses. A case study water treatment plant in Malaysia which encompassed both the UF and conventional media filtration systems are used to elucidate this comparison study. River water source is fed as surface raw water to both systems. The UF system has exhibited consistent filtrate quality regardless of the fluctuation of raw water quality. Sludge discharged from the UF backwash remains the same characteristics as the feed water except with higher concentration of solids content. However, sludge from the conventional system contains high concentration of Aluminium residual originating from the coagulant. The UF system caused higher water losses compared to the conventional system. As for operation and maintenance expenditures, the conventional systems are more economical. Sensitivity analyses have been carried out on the capital expenditure and operational expenditure. Precaution measures have been taken to ensure all data collected are relevant and accurate. More than 12 months of treatment systems operational data are collected, compiled and analysed to substantiate the results. This study intends to highlight the commercial and environmental sustainability of both systems. The major contribution and novelty of this work is that it provides useful reference to the decision makers and stakeholders on the selection of treatment process for industrial-scale drinking water facilities to accommodate their current and future requirements.

KW - Drinking water

KW - Media filtration

KW - Sustainable development

KW - Ultrafiltration

U2 - 10.1016/j.jclepro.2015.10.037

DO - 10.1016/j.jclepro.2015.10.037

M3 - Journal article

AN - SCOPUS:84958107696

VL - 112

SP - 3152

EP - 3163

JO - Journal of Cleaner Production

JF - Journal of Cleaner Production

SN - 0959-6526

ER -