Home > Research > Publications & Outputs > Gas chromatographic determination of volatile a...
View graph of relations

Gas chromatographic determination of volatile alkenes with on-column bromination and electron-capture detection.

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Published

Standard

Gas chromatographic determination of volatile alkenes with on-column bromination and electron-capture detection. / Cao, Xu-Liang; Hewitt, C. N.
In: Journal of Chromatography A, Vol. 690, No. 2, 1995, p. 187-195.

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Harvard

APA

Vancouver

Cao X-L, Hewitt CN. Gas chromatographic determination of volatile alkenes with on-column bromination and electron-capture detection. Journal of Chromatography A. 1995;690(2):187-195. doi: 10.1016/0021-9673(94)00855-4

Author

Cao, Xu-Liang ; Hewitt, C. N. / Gas chromatographic determination of volatile alkenes with on-column bromination and electron-capture detection. In: Journal of Chromatography A. 1995 ; Vol. 690, No. 2. pp. 187-195.

Bibtex

@article{c23d5133987b4ebcb8f90c36130be73e,
title = "Gas chromatographic determination of volatile alkenes with on-column bromination and electron-capture detection.",
abstract = "A method is described for the gas chromatographic-electron-capture detection determination of alkenes via on-column bromination reactions. Pyridinium bromide perbromide (PBPB) was used as the Br2 source, and a cholesterol-glass beads mixture, treated with methanol, was used to remove excess Br2. The optimum ratio of cholesterol to glass beads was found to be 1:10, at which 93% of the bromine released from PBPB can be removed, without removal of the derivitized analytes. The conversion efficiency of alkene to the brominated derivative is extremely low (less than 2%) for ethene, whereas for propene and 1-butene it is 41 and 79%, respectively. For C3---C5 alkenes, this method is 200–300 times more sensitive than analysis of the underivitized analytes by using conventional flame ionization detection.",
author = "Xu-Liang Cao and Hewitt, {C. N.}",
year = "1995",
doi = "10.1016/0021-9673(94)00855-4",
language = "English",
volume = "690",
pages = "187--195",
journal = "Journal of Chromatography A",
issn = "1873-3778",
publisher = "Elsevier",
number = "2",

}

RIS

TY - JOUR

T1 - Gas chromatographic determination of volatile alkenes with on-column bromination and electron-capture detection.

AU - Cao, Xu-Liang

AU - Hewitt, C. N.

PY - 1995

Y1 - 1995

N2 - A method is described for the gas chromatographic-electron-capture detection determination of alkenes via on-column bromination reactions. Pyridinium bromide perbromide (PBPB) was used as the Br2 source, and a cholesterol-glass beads mixture, treated with methanol, was used to remove excess Br2. The optimum ratio of cholesterol to glass beads was found to be 1:10, at which 93% of the bromine released from PBPB can be removed, without removal of the derivitized analytes. The conversion efficiency of alkene to the brominated derivative is extremely low (less than 2%) for ethene, whereas for propene and 1-butene it is 41 and 79%, respectively. For C3---C5 alkenes, this method is 200–300 times more sensitive than analysis of the underivitized analytes by using conventional flame ionization detection.

AB - A method is described for the gas chromatographic-electron-capture detection determination of alkenes via on-column bromination reactions. Pyridinium bromide perbromide (PBPB) was used as the Br2 source, and a cholesterol-glass beads mixture, treated with methanol, was used to remove excess Br2. The optimum ratio of cholesterol to glass beads was found to be 1:10, at which 93% of the bromine released from PBPB can be removed, without removal of the derivitized analytes. The conversion efficiency of alkene to the brominated derivative is extremely low (less than 2%) for ethene, whereas for propene and 1-butene it is 41 and 79%, respectively. For C3---C5 alkenes, this method is 200–300 times more sensitive than analysis of the underivitized analytes by using conventional flame ionization detection.

U2 - 10.1016/0021-9673(94)00855-4

DO - 10.1016/0021-9673(94)00855-4

M3 - Journal article

VL - 690

SP - 187

EP - 195

JO - Journal of Chromatography A

JF - Journal of Chromatography A

SN - 1873-3778

IS - 2

ER -