Home > Research > Publications & Outputs > Interstrip capacitance stabilization at low hum...
View graph of relations

Interstrip capacitance stabilization at low humidity.

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Published
<mark>Journal publication date</mark>1/05/2006
<mark>Journal</mark>Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Issue number1
Volume560
Number of pages4
Pages (from-to)118-121
Publication StatusPublished
<mark>Original language</mark>English

Abstract

A long-term stabilisation of the interstrip capacitance after bias application is investigated with emphasis on low ambient humidity conditions. The measurements are made with ATLAS SCT microstrip detectors produced by Hamamatsu. It is shown that after the application of 150 V bias the interstrip capacitance is higher by 25–30% than its stable value. It is demonstrated that at low absolute humidity, mandatory for the SCT operation at subzero temperatures, the stabilisation time may be of order of months. Since the interstrip capacitance is one of the major sources of front-end electronics noise the results are important for the optimisation of operating conditions for the ATLAS SCT.