Home > Research > Publications & Outputs > Investigation of possible multipactor discharge...
View graph of relations

Investigation of possible multipactor discharge in a klystron input cavity.

Research output: Contribution to conference - Without ISBN/ISSN Other

Published

Standard

Investigation of possible multipactor discharge in a klystron input cavity. / Hill, C.; Carter, Richard G.
2006. 81-82 2006 IEEE International Vacuum Electronics Conference held jointly with 2006 IEEE International Vacuum Electron Sources, Monterey, California.

Research output: Contribution to conference - Without ISBN/ISSN Other

Harvard

Hill, C & Carter, RG 2006, 'Investigation of possible multipactor discharge in a klystron input cavity.', 2006 IEEE International Vacuum Electronics Conference held jointly with 2006 IEEE International Vacuum Electron Sources, Monterey, California, 25/04/06 - 27/04/06 pp. 81-82.

APA

Hill, C., & Carter, R. G. (2006). Investigation of possible multipactor discharge in a klystron input cavity.. 81-82. 2006 IEEE International Vacuum Electronics Conference held jointly with 2006 IEEE International Vacuum Electron Sources, Monterey, California.

Vancouver

Hill C, Carter RG. Investigation of possible multipactor discharge in a klystron input cavity.. 2006. 2006 IEEE International Vacuum Electronics Conference held jointly with 2006 IEEE International Vacuum Electron Sources, Monterey, California.

Author

Hill, C. ; Carter, Richard G. / Investigation of possible multipactor discharge in a klystron input cavity. 2006 IEEE International Vacuum Electronics Conference held jointly with 2006 IEEE International Vacuum Electron Sources, Monterey, California.2 p.

Bibtex

@conference{6dfe91dee3f44fbcb59f7725e51c39e5,
title = "Investigation of possible multipactor discharge in a klystron input cavity.",
abstract = "A detailed experimental study has been made of suspected multipactor discharge in a klystron input cavity in the presence of an axial magneticfield.. The existence of the discharge was detected by changes in the return loss at the input coupler. This method does not require any modification of the cavity. Discharges appeared to take place over a range of input powers from 5 W up to 100 W for two distinct ranges of the magnetic field. Tests with a hand-heldpermanent magnet suggested that the discharges are located around the equator of the cavity. Comparison with theory confirmed that the lower band is probably a single-surface crossed-field multipactor discharge. Investigation of the upper band is continuing.",
author = "C. Hill and Carter, {Richard G.}",
note = "7th IEEE International Vacuum Electronics Conference (IVEC)/6th IEEE International Vacuum Electron Sources Conference (IVESC), Monterey, CA, APR 25-27, 2006; 2006 IEEE International Vacuum Electronics Conference held jointly with 2006 IEEE International Vacuum Electron Sources ; Conference date: 25-04-2006 Through 27-04-2006",
year = "2006",
language = "English",
pages = "81--82",

}

RIS

TY - CONF

T1 - Investigation of possible multipactor discharge in a klystron input cavity.

AU - Hill, C.

AU - Carter, Richard G.

N1 - 7th IEEE International Vacuum Electronics Conference (IVEC)/6th IEEE International Vacuum Electron Sources Conference (IVESC), Monterey, CA, APR 25-27, 2006

PY - 2006

Y1 - 2006

N2 - A detailed experimental study has been made of suspected multipactor discharge in a klystron input cavity in the presence of an axial magneticfield.. The existence of the discharge was detected by changes in the return loss at the input coupler. This method does not require any modification of the cavity. Discharges appeared to take place over a range of input powers from 5 W up to 100 W for two distinct ranges of the magnetic field. Tests with a hand-heldpermanent magnet suggested that the discharges are located around the equator of the cavity. Comparison with theory confirmed that the lower band is probably a single-surface crossed-field multipactor discharge. Investigation of the upper band is continuing.

AB - A detailed experimental study has been made of suspected multipactor discharge in a klystron input cavity in the presence of an axial magneticfield.. The existence of the discharge was detected by changes in the return loss at the input coupler. This method does not require any modification of the cavity. Discharges appeared to take place over a range of input powers from 5 W up to 100 W for two distinct ranges of the magnetic field. Tests with a hand-heldpermanent magnet suggested that the discharges are located around the equator of the cavity. Comparison with theory confirmed that the lower band is probably a single-surface crossed-field multipactor discharge. Investigation of the upper band is continuing.

M3 - Other

SP - 81

EP - 82

T2 - 2006 IEEE International Vacuum Electronics Conference held jointly with 2006 IEEE International Vacuum Electron Sources

Y2 - 25 April 2006 through 27 April 2006

ER -