Home > Research > Publications & Outputs > Measurement of the underground atmospheric muon...

Electronic data

  • PhysRevD.83.032011

    Rights statement: © 2011 American Physical Society

    Final published version, 352 KB, PDF document

Links

Text available via DOI:

View graph of relations

Measurement of the underground atmospheric muon charge ratio using the MINOS Near Detector

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Published

Standard

Measurement of the underground atmospheric muon charge ratio using the MINOS Near Detector. / MINOS Collaboration.
In: Physical Review D – Particles and Fields, Vol. 83, No. 3, 032011, 28.02.2011.

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Harvard

MINOS Collaboration 2011, 'Measurement of the underground atmospheric muon charge ratio using the MINOS Near Detector', Physical Review D – Particles and Fields, vol. 83, no. 3, 032011. https://doi.org/10.1103/PhysRevD.83.032011

APA

MINOS Collaboration (2011). Measurement of the underground atmospheric muon charge ratio using the MINOS Near Detector. Physical Review D – Particles and Fields, 83(3), Article 032011. https://doi.org/10.1103/PhysRevD.83.032011

Vancouver

MINOS Collaboration. Measurement of the underground atmospheric muon charge ratio using the MINOS Near Detector. Physical Review D – Particles and Fields. 2011 Feb 28;83(3):032011. doi: 10.1103/PhysRevD.83.032011

Author

MINOS Collaboration. / Measurement of the underground atmospheric muon charge ratio using the MINOS Near Detector. In: Physical Review D – Particles and Fields. 2011 ; Vol. 83, No. 3.

Bibtex

@article{b1f1cc38c168451fb3a0419938b5255a,
title = "Measurement of the underground atmospheric muon charge ratio using the MINOS Near Detector",
abstract = "The magnetized MINOS Near Detector, at a depth of 225 mwe, is used to measure the atmospheric muon charge ratio. The ratio of observed positive to negative atmospheric muon rates, using 301 days of data, is measured to be 1.266±0.001(stat)-0.014+0.015(syst). This measurement is consistent with previous results from other shallow underground detectors and is 0.108±0.019(stat+syst) lower than the measurement at the functionally identical MINOS Far Detector at a depth of 2070 mwe. This increase in charge ratio as a function of depth is consistent with an increase in the fraction of muons arising from kaon decay for increasing muon surface energies.",
author = "P. Adamson and Jaroslaw Nowak and {MINOS Collaboration}",
note = "{\textcopyright} 2011 American Physical Society",
year = "2011",
month = feb,
day = "28",
doi = "10.1103/PhysRevD.83.032011",
language = "English",
volume = "83",
journal = "Physical Review D – Particles and Fields",
issn = "1550-2368",
publisher = "American Physical Society",
number = "3",

}

RIS

TY - JOUR

T1 - Measurement of the underground atmospheric muon charge ratio using the MINOS Near Detector

AU - Adamson, P.

AU - Nowak, Jaroslaw

AU - MINOS Collaboration

N1 - © 2011 American Physical Society

PY - 2011/2/28

Y1 - 2011/2/28

N2 - The magnetized MINOS Near Detector, at a depth of 225 mwe, is used to measure the atmospheric muon charge ratio. The ratio of observed positive to negative atmospheric muon rates, using 301 days of data, is measured to be 1.266±0.001(stat)-0.014+0.015(syst). This measurement is consistent with previous results from other shallow underground detectors and is 0.108±0.019(stat+syst) lower than the measurement at the functionally identical MINOS Far Detector at a depth of 2070 mwe. This increase in charge ratio as a function of depth is consistent with an increase in the fraction of muons arising from kaon decay for increasing muon surface energies.

AB - The magnetized MINOS Near Detector, at a depth of 225 mwe, is used to measure the atmospheric muon charge ratio. The ratio of observed positive to negative atmospheric muon rates, using 301 days of data, is measured to be 1.266±0.001(stat)-0.014+0.015(syst). This measurement is consistent with previous results from other shallow underground detectors and is 0.108±0.019(stat+syst) lower than the measurement at the functionally identical MINOS Far Detector at a depth of 2070 mwe. This increase in charge ratio as a function of depth is consistent with an increase in the fraction of muons arising from kaon decay for increasing muon surface energies.

U2 - 10.1103/PhysRevD.83.032011

DO - 10.1103/PhysRevD.83.032011

M3 - Journal article

VL - 83

JO - Physical Review D – Particles and Fields

JF - Physical Review D – Particles and Fields

SN - 1550-2368

IS - 3

M1 - 032011

ER -