Home > Research > Publications & Outputs > Optimization of array design for TIBr imaging d...

Text available via DOI:

View graph of relations

Optimization of array design for TIBr imaging detectors.

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Published

Standard

Optimization of array design for TIBr imaging detectors. / den Hartog, Roland H.; Owens, Alan; Kozorezov, Alex G. et al.
In: Proceedings of SPIE, Vol. 4851, 11.08.2003, p. 922-932.

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Harvard

den Hartog, RH, Owens, A, Kozorezov, AG, Bavdaz, M, Peacock, AJ, Gostilo, V, Lisjutin, I & Zatoloka, S 2003, 'Optimization of array design for TIBr imaging detectors.', Proceedings of SPIE, vol. 4851, pp. 922-932. https://doi.org/10.1117/12.461574

APA

den Hartog, R. H., Owens, A., Kozorezov, A. G., Bavdaz, M., Peacock, A. J., Gostilo, V., Lisjutin, I., & Zatoloka, S. (2003). Optimization of array design for TIBr imaging detectors. Proceedings of SPIE, 4851, 922-932. https://doi.org/10.1117/12.461574

Vancouver

den Hartog RH, Owens A, Kozorezov AG, Bavdaz M, Peacock AJ, Gostilo V et al. Optimization of array design for TIBr imaging detectors. Proceedings of SPIE. 2003 Aug 11;4851:922-932. doi: 10.1117/12.461574

Author

den Hartog, Roland H. ; Owens, Alan; ; Kozorezov, Alex G. et al. / Optimization of array design for TIBr imaging detectors. In: Proceedings of SPIE. 2003 ; Vol. 4851. pp. 922-932.

Bibtex

@article{8b32f66cc69b4e91a6061b95611c71d5,
title = "Optimization of array design for TIBr imaging detectors.",
abstract = "Thallium bromide (TlBr) has attracted attention as an exceptional radiation detector material. Due to its high atomic number (81 for Tl, 35 for Br) it has excellent stopping power for hard X-ray and gamma rays and due to its high bandgap (2.7 eV) its operation requires no or only modest cooling. Promising energy resolutions have been demonstrated with detectors fabricated from high-purity samples (3.3 keV for 60 keV photons). These properties make TlBr the material of choice for hard X-ray imaging spectrometers in applications where small weight and/or size is important (e.g. space astrophysics and nuclear medicine). The charge response and spectroscopic performance of a semiconductor imaging array depend not only on material properties but on the pixel properties as well. It has been demonstrated, for instance, that the ratio between pixel size and thickness of the detector is an important factor for the charge response. This is known as the small-pixel or near-field effect. In this paper we investigate the optimization of TlBr pixel properties in a broader context, taking into account material properties (electron and hole mobility, diffusion and trapping), fabrication details and the specific energy range of application, with a view to optimizing both the response and energy resolution.",
author = "{den Hartog}, {Roland H.} and Alan; Owens and Kozorezov, {Alex G.} and Marcos; Bavdaz and Peacock, {Anthony J.} and Vladimir; Gostilo and I. Lisjutin and Sergey; Zatoloka",
year = "2003",
month = aug,
day = "11",
doi = "10.1117/12.461574",
language = "English",
volume = "4851",
pages = "922--932",
journal = "Proceedings of SPIE",
issn = "0277-786X",
publisher = "SPIE",

}

RIS

TY - JOUR

T1 - Optimization of array design for TIBr imaging detectors.

AU - den Hartog, Roland H.

AU - Owens, Alan;

AU - Kozorezov, Alex G.

AU - Bavdaz, Marcos;

AU - Peacock, Anthony J.

AU - Gostilo, Vladimir;

AU - Lisjutin, I.

AU - Zatoloka, Sergey;

PY - 2003/8/11

Y1 - 2003/8/11

N2 - Thallium bromide (TlBr) has attracted attention as an exceptional radiation detector material. Due to its high atomic number (81 for Tl, 35 for Br) it has excellent stopping power for hard X-ray and gamma rays and due to its high bandgap (2.7 eV) its operation requires no or only modest cooling. Promising energy resolutions have been demonstrated with detectors fabricated from high-purity samples (3.3 keV for 60 keV photons). These properties make TlBr the material of choice for hard X-ray imaging spectrometers in applications where small weight and/or size is important (e.g. space astrophysics and nuclear medicine). The charge response and spectroscopic performance of a semiconductor imaging array depend not only on material properties but on the pixel properties as well. It has been demonstrated, for instance, that the ratio between pixel size and thickness of the detector is an important factor for the charge response. This is known as the small-pixel or near-field effect. In this paper we investigate the optimization of TlBr pixel properties in a broader context, taking into account material properties (electron and hole mobility, diffusion and trapping), fabrication details and the specific energy range of application, with a view to optimizing both the response and energy resolution.

AB - Thallium bromide (TlBr) has attracted attention as an exceptional radiation detector material. Due to its high atomic number (81 for Tl, 35 for Br) it has excellent stopping power for hard X-ray and gamma rays and due to its high bandgap (2.7 eV) its operation requires no or only modest cooling. Promising energy resolutions have been demonstrated with detectors fabricated from high-purity samples (3.3 keV for 60 keV photons). These properties make TlBr the material of choice for hard X-ray imaging spectrometers in applications where small weight and/or size is important (e.g. space astrophysics and nuclear medicine). The charge response and spectroscopic performance of a semiconductor imaging array depend not only on material properties but on the pixel properties as well. It has been demonstrated, for instance, that the ratio between pixel size and thickness of the detector is an important factor for the charge response. This is known as the small-pixel or near-field effect. In this paper we investigate the optimization of TlBr pixel properties in a broader context, taking into account material properties (electron and hole mobility, diffusion and trapping), fabrication details and the specific energy range of application, with a view to optimizing both the response and energy resolution.

U2 - 10.1117/12.461574

DO - 10.1117/12.461574

M3 - Journal article

VL - 4851

SP - 922

EP - 932

JO - Proceedings of SPIE

JF - Proceedings of SPIE

SN - 0277-786X

ER -