Home > Research > Publications & Outputs > Quantitative trace analysis of polyfluorinated ...
View graph of relations

Quantitative trace analysis of polyfluorinated alkyl substances (PFAS) in ambient air samples from Mace Head (Ireland) : A method inter-comparison.

Research output: Contribution to Journal/MagazineJournal article

Published

Standard

Quantitative trace analysis of polyfluorinated alkyl substances (PFAS) in ambient air samples from Mace Head (Ireland) : A method inter-comparison. / Jahnke, Annika; Barber, Jonathan L.; Jones, Kevin C. et al.
In: Atmospheric Environment, Vol. 43, No. 4, 02.2009, p. 844-850.

Research output: Contribution to Journal/MagazineJournal article

Harvard

APA

Vancouver

Jahnke A, Barber JL, Jones KC, Temme C. Quantitative trace analysis of polyfluorinated alkyl substances (PFAS) in ambient air samples from Mace Head (Ireland) : A method inter-comparison. Atmospheric Environment. 2009 Feb;43(4):844-850. doi: 10.1016/j.atmosenv.2008.10.049

Author

Jahnke, Annika ; Barber, Jonathan L. ; Jones, Kevin C. et al. / Quantitative trace analysis of polyfluorinated alkyl substances (PFAS) in ambient air samples from Mace Head (Ireland) : A method inter-comparison. In: Atmospheric Environment. 2009 ; Vol. 43, No. 4. pp. 844-850.

Bibtex

@article{b9be626df8e745e19fe7ccbb7a93bf85,
title = "Quantitative trace analysis of polyfluorinated alkyl substances (PFAS) in ambient air samples from Mace Head (Ireland) : A method inter-comparison.",
abstract = "A method intercomparison study of analytical methods for the determination of neutral, volatile polyfluorinated alkyl substances (PFAS) was carried out in March, 2006. Environmental air samples were collected in triplicate at the European background site Mace Head on the west coast of Ireland, a site dominated by {\textquoteleft}clean{\textquoteright} westerly winds coming across the Atlantic. Extraction and analysis were performed at two laboratories active in PFAS research using their in-house methods. Airborne polyfluorinated telomer alcohols (FTOHs), fluorooctane sulfonamides and sulfonamidoethanols (FOSAs/FOSEs) as well as additional polyfluorinated compounds were investigated. Different native and isotope-labelled internal standards (IS) were applied at various steps in the analytical procedure to evaluate the different quantification strategies. Field blanks revealed no major blank problems. European background concentrations observed at Mace Head were found to be in a similar range to Arctic data reported in the literature. Due to trace-levels at the remote site, only FTOH data sets were complete and could therefore be compared between the laboratories. Additionally, FOSEs could partly be included. Data comparison revealed that despite the challenges inherent in analysis of airborne PFAS and the low concentrations, all methods applied in this study obtained similar results. However, application of isotope-labelled IS early in the analytical procedure leads to more precise results and is therefore recommended.",
keywords = "Polyfluorinated alkyl substances (PFAS), Air analysis, Method intercomparison, Isotope-labelled internal standards, European background levels",
author = "Annika Jahnke and Barber, {Jonathan L.} and Jones, {Kevin C.} and Christian Temme",
year = "2009",
month = feb,
doi = "10.1016/j.atmosenv.2008.10.049",
language = "English",
volume = "43",
pages = "844--850",
journal = "Atmospheric Environment",
issn = "1352-2310",
publisher = "PERGAMON-ELSEVIER SCIENCE LTD",
number = "4",

}

RIS

TY - JOUR

T1 - Quantitative trace analysis of polyfluorinated alkyl substances (PFAS) in ambient air samples from Mace Head (Ireland) : A method inter-comparison.

AU - Jahnke, Annika

AU - Barber, Jonathan L.

AU - Jones, Kevin C.

AU - Temme, Christian

PY - 2009/2

Y1 - 2009/2

N2 - A method intercomparison study of analytical methods for the determination of neutral, volatile polyfluorinated alkyl substances (PFAS) was carried out in March, 2006. Environmental air samples were collected in triplicate at the European background site Mace Head on the west coast of Ireland, a site dominated by ‘clean’ westerly winds coming across the Atlantic. Extraction and analysis were performed at two laboratories active in PFAS research using their in-house methods. Airborne polyfluorinated telomer alcohols (FTOHs), fluorooctane sulfonamides and sulfonamidoethanols (FOSAs/FOSEs) as well as additional polyfluorinated compounds were investigated. Different native and isotope-labelled internal standards (IS) were applied at various steps in the analytical procedure to evaluate the different quantification strategies. Field blanks revealed no major blank problems. European background concentrations observed at Mace Head were found to be in a similar range to Arctic data reported in the literature. Due to trace-levels at the remote site, only FTOH data sets were complete and could therefore be compared between the laboratories. Additionally, FOSEs could partly be included. Data comparison revealed that despite the challenges inherent in analysis of airborne PFAS and the low concentrations, all methods applied in this study obtained similar results. However, application of isotope-labelled IS early in the analytical procedure leads to more precise results and is therefore recommended.

AB - A method intercomparison study of analytical methods for the determination of neutral, volatile polyfluorinated alkyl substances (PFAS) was carried out in March, 2006. Environmental air samples were collected in triplicate at the European background site Mace Head on the west coast of Ireland, a site dominated by ‘clean’ westerly winds coming across the Atlantic. Extraction and analysis were performed at two laboratories active in PFAS research using their in-house methods. Airborne polyfluorinated telomer alcohols (FTOHs), fluorooctane sulfonamides and sulfonamidoethanols (FOSAs/FOSEs) as well as additional polyfluorinated compounds were investigated. Different native and isotope-labelled internal standards (IS) were applied at various steps in the analytical procedure to evaluate the different quantification strategies. Field blanks revealed no major blank problems. European background concentrations observed at Mace Head were found to be in a similar range to Arctic data reported in the literature. Due to trace-levels at the remote site, only FTOH data sets were complete and could therefore be compared between the laboratories. Additionally, FOSEs could partly be included. Data comparison revealed that despite the challenges inherent in analysis of airborne PFAS and the low concentrations, all methods applied in this study obtained similar results. However, application of isotope-labelled IS early in the analytical procedure leads to more precise results and is therefore recommended.

KW - Polyfluorinated alkyl substances (PFAS)

KW - Air analysis

KW - Method intercomparison

KW - Isotope-labelled internal standards

KW - European background levels

U2 - 10.1016/j.atmosenv.2008.10.049

DO - 10.1016/j.atmosenv.2008.10.049

M3 - Journal article

VL - 43

SP - 844

EP - 850

JO - Atmospheric Environment

JF - Atmospheric Environment

SN - 1352-2310

IS - 4

ER -