Standard
Recent progress on a co-harmonic gyrotron. /
Constable, David A.; Ronald, Kevin; He, Wenlong et al.
2011 IEEE International Vacuum Electronics Conference, IVEC-2011. IEEE, 2011. p. 107-108 5746898 (2011 IEEE International Vacuum Electronics Conference, IVEC-2011).
Research output: Contribution in Book/Report/Proceedings - With ISBN/ISSN › Conference contribution/Paper › peer-review
Harvard
Constable, DA, Ronald, K, He, W, Phelps, ADR, Cross, AW, Bandurkin, IV, Savilov, AV & Bratman, VL 2011,
Recent progress on a co-harmonic gyrotron. in
2011 IEEE International Vacuum Electronics Conference, IVEC-2011., 5746898, 2011 IEEE International Vacuum Electronics Conference, IVEC-2011, IEEE, pp. 107-108, 2011 IEEE International Vacuum Electronics Conference, IVEC-2011, Bangalore, India,
21/02/11.
https://doi.org/10.1109/IVEC.2011.5746898
APA
Constable, D. A., Ronald, K., He, W., Phelps, A. D. R., Cross, A. W., Bandurkin, I. V., Savilov, A. V., & Bratman, V. L. (2011).
Recent progress on a co-harmonic gyrotron. In
2011 IEEE International Vacuum Electronics Conference, IVEC-2011 (pp. 107-108). Article 5746898 (2011 IEEE International Vacuum Electronics Conference, IVEC-2011). IEEE.
https://doi.org/10.1109/IVEC.2011.5746898
Vancouver
Constable DA, Ronald K, He W, Phelps ADR, Cross AW, Bandurkin IV et al.
Recent progress on a co-harmonic gyrotron. In 2011 IEEE International Vacuum Electronics Conference, IVEC-2011. IEEE. 2011. p. 107-108. 5746898. (2011 IEEE International Vacuum Electronics Conference, IVEC-2011). doi: 10.1109/IVEC.2011.5746898
Author
Bibtex
@inproceedings{f708e5a2ac2b493a964815da20664c65,
title = "Recent progress on a co-harmonic gyrotron",
abstract = "Results from numerical simulations have demonstrated the principle of a co-harmonic gyrotron, operating with a novel cavity. Such a cavity is capable of generating coherent radiation at both the 2nd and 4th harmonics of the electron cyclotron frequency simultaneously, at frequencies of 37.5 GHz and 75 GHz. Further results are presented here, including refinements to the output section of the cavity, as well as on the on-going testing of the cavity and its associated components, which are required to generate the operating modes of interest.",
keywords = "frequency multiplication, gyro-device, Gyrotron, harmonic, millimetre-wave",
author = "Constable, {David A.} and Kevin Ronald and Wenlong He and Phelps, {Alan D.R.} and Cross, {Adrian W.} and Bandurkin, {Ilya V.} and Savilov, {Andrey V.} and Bratman, {Vladimir L.}",
year = "2011",
month = may,
day = "13",
doi = "10.1109/IVEC.2011.5746898",
language = "English",
isbn = "9781424486595",
series = "2011 IEEE International Vacuum Electronics Conference, IVEC-2011",
publisher = "IEEE",
pages = "107--108",
booktitle = "2011 IEEE International Vacuum Electronics Conference, IVEC-2011",
note = "2011 IEEE International Vacuum Electronics Conference, IVEC-2011 ; Conference date: 21-02-2011 Through 24-02-2011",
}
RIS
TY - GEN
T1 - Recent progress on a co-harmonic gyrotron
AU - Constable, David A.
AU - Ronald, Kevin
AU - He, Wenlong
AU - Phelps, Alan D.R.
AU - Cross, Adrian W.
AU - Bandurkin, Ilya V.
AU - Savilov, Andrey V.
AU - Bratman, Vladimir L.
PY - 2011/5/13
Y1 - 2011/5/13
N2 - Results from numerical simulations have demonstrated the principle of a co-harmonic gyrotron, operating with a novel cavity. Such a cavity is capable of generating coherent radiation at both the 2nd and 4th harmonics of the electron cyclotron frequency simultaneously, at frequencies of 37.5 GHz and 75 GHz. Further results are presented here, including refinements to the output section of the cavity, as well as on the on-going testing of the cavity and its associated components, which are required to generate the operating modes of interest.
AB - Results from numerical simulations have demonstrated the principle of a co-harmonic gyrotron, operating with a novel cavity. Such a cavity is capable of generating coherent radiation at both the 2nd and 4th harmonics of the electron cyclotron frequency simultaneously, at frequencies of 37.5 GHz and 75 GHz. Further results are presented here, including refinements to the output section of the cavity, as well as on the on-going testing of the cavity and its associated components, which are required to generate the operating modes of interest.
KW - frequency multiplication
KW - gyro-device
KW - Gyrotron
KW - harmonic
KW - millimetre-wave
U2 - 10.1109/IVEC.2011.5746898
DO - 10.1109/IVEC.2011.5746898
M3 - Conference contribution/Paper
AN - SCOPUS:79955779668
SN - 9781424486595
T3 - 2011 IEEE International Vacuum Electronics Conference, IVEC-2011
SP - 107
EP - 108
BT - 2011 IEEE International Vacuum Electronics Conference, IVEC-2011
PB - IEEE
T2 - 2011 IEEE International Vacuum Electronics Conference, IVEC-2011
Y2 - 21 February 2011 through 24 February 2011
ER -