Home > Research > Publications & Outputs > The influence of profiled sheeting thickness an...
View graph of relations

The influence of profiled sheeting thickness and shear connector's position on strength and ductility of headed shear connector

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Published

Standard

The influence of profiled sheeting thickness and shear connector's position on strength and ductility of headed shear connector. / Qureshi, Jawed; Lam, Dennis; Ye, Jianqiao.
In: Engineering Structures, Vol. 33, No. 5, 05.2011, p. 1643-1656.

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Harvard

APA

Vancouver

Qureshi J, Lam D, Ye J. The influence of profiled sheeting thickness and shear connector's position on strength and ductility of headed shear connector. Engineering Structures. 2011 May;33(5):1643-1656. doi: 10.1016/j.engstruct.2011.01.035

Author

Qureshi, Jawed ; Lam, Dennis ; Ye, Jianqiao. / The influence of profiled sheeting thickness and shear connector's position on strength and ductility of headed shear connector. In: Engineering Structures. 2011 ; Vol. 33, No. 5. pp. 1643-1656.

Bibtex

@article{504a9fcabf1d433d9af901d645365813,
title = "The influence of profiled sheeting thickness and shear connector's position on strength and ductility of headed shear connector",
abstract = "A three-dimensional finite element model is developed, validated and used in the parametric study to investigate the influence of shear stud's position and profiled sheeting thickness on the strength, ductility and failure modes of the headed shear stud welded to the modern profiled sheeting. A total of 240 push tests were analysed with different sheeting thicknesses, positions of the shear stud in the trough, concrete strengths and transverse spacings. The results showed that the sheeting thickness influenced the shear connector resistance of studs placed in the unfavourable position more than studs placed in favourable and central positions. The strength of the shear connector placed in the unfavourable position increased by as much as 30% when the sheeting thickness was increased. The shear connector resistance of the unfavourable stud was found to be primarily a function of the strength and the thickness of the profiled sheeting rather than the concrete strength. The strength prediction equations for unfavourable and central studs were also proposed. The results suggested that the strength of the shear connector increased as the distance of the shear stud increased from the mid-height of the deck rib in the load bearing direction of the stud. The load-slip behaviour of the studs in the unfavourable position was more ductile than the studs in the favourable position, with slip of 2-4 times higher. It was found that the increase in sheeting thickness and transverse spacing improved the ductility of the stud in unfavourable position, but had no effect on the stud in the favourable position. The failure modes suggested that the favourable and central studs failed by concrete cone failure and unfavourable studs failed by rib punching together with crushing of the narrow strip of the concrete in front of the stud. (C) 2011 Elsevier Ltd. All rights reserved.",
keywords = "Shear stud{\textquoteright}s position, Profiled sheeting thickness , Unfavourable stud , Shear connector resistance , Push test , Composite beam",
author = "Jawed Qureshi and Dennis Lam and Jianqiao Ye",
year = "2011",
month = may,
doi = "10.1016/j.engstruct.2011.01.035",
language = "English",
volume = "33",
pages = "1643--1656",
journal = "Engineering Structures",
issn = "0141-0296",
publisher = "Elsevier BV",
number = "5",

}

RIS

TY - JOUR

T1 - The influence of profiled sheeting thickness and shear connector's position on strength and ductility of headed shear connector

AU - Qureshi, Jawed

AU - Lam, Dennis

AU - Ye, Jianqiao

PY - 2011/5

Y1 - 2011/5

N2 - A three-dimensional finite element model is developed, validated and used in the parametric study to investigate the influence of shear stud's position and profiled sheeting thickness on the strength, ductility and failure modes of the headed shear stud welded to the modern profiled sheeting. A total of 240 push tests were analysed with different sheeting thicknesses, positions of the shear stud in the trough, concrete strengths and transverse spacings. The results showed that the sheeting thickness influenced the shear connector resistance of studs placed in the unfavourable position more than studs placed in favourable and central positions. The strength of the shear connector placed in the unfavourable position increased by as much as 30% when the sheeting thickness was increased. The shear connector resistance of the unfavourable stud was found to be primarily a function of the strength and the thickness of the profiled sheeting rather than the concrete strength. The strength prediction equations for unfavourable and central studs were also proposed. The results suggested that the strength of the shear connector increased as the distance of the shear stud increased from the mid-height of the deck rib in the load bearing direction of the stud. The load-slip behaviour of the studs in the unfavourable position was more ductile than the studs in the favourable position, with slip of 2-4 times higher. It was found that the increase in sheeting thickness and transverse spacing improved the ductility of the stud in unfavourable position, but had no effect on the stud in the favourable position. The failure modes suggested that the favourable and central studs failed by concrete cone failure and unfavourable studs failed by rib punching together with crushing of the narrow strip of the concrete in front of the stud. (C) 2011 Elsevier Ltd. All rights reserved.

AB - A three-dimensional finite element model is developed, validated and used in the parametric study to investigate the influence of shear stud's position and profiled sheeting thickness on the strength, ductility and failure modes of the headed shear stud welded to the modern profiled sheeting. A total of 240 push tests were analysed with different sheeting thicknesses, positions of the shear stud in the trough, concrete strengths and transverse spacings. The results showed that the sheeting thickness influenced the shear connector resistance of studs placed in the unfavourable position more than studs placed in favourable and central positions. The strength of the shear connector placed in the unfavourable position increased by as much as 30% when the sheeting thickness was increased. The shear connector resistance of the unfavourable stud was found to be primarily a function of the strength and the thickness of the profiled sheeting rather than the concrete strength. The strength prediction equations for unfavourable and central studs were also proposed. The results suggested that the strength of the shear connector increased as the distance of the shear stud increased from the mid-height of the deck rib in the load bearing direction of the stud. The load-slip behaviour of the studs in the unfavourable position was more ductile than the studs in the favourable position, with slip of 2-4 times higher. It was found that the increase in sheeting thickness and transverse spacing improved the ductility of the stud in unfavourable position, but had no effect on the stud in the favourable position. The failure modes suggested that the favourable and central studs failed by concrete cone failure and unfavourable studs failed by rib punching together with crushing of the narrow strip of the concrete in front of the stud. (C) 2011 Elsevier Ltd. All rights reserved.

KW - Shear stud’s position

KW - Profiled sheeting thickness

KW - Unfavourable stud

KW - Shear connector resistance

KW - Push test

KW - Composite beam

U2 - 10.1016/j.engstruct.2011.01.035

DO - 10.1016/j.engstruct.2011.01.035