Home > Research > Publications & Outputs > The Upgraded D0 detector.
View graph of relations

The Upgraded D0 detector.

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Published

Standard

The Upgraded D0 detector. / Fox, H.; Abazov, V. M.; Abbott, M. et al.
In: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 565, No. 2, 15.09.2006, p. 463-537.

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Harvard

Fox, H, Abazov, VM, Abbott, M & Abolins, M 2006, 'The Upgraded D0 detector.', Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, vol. 565, no. 2, pp. 463-537. https://doi.org/10.1016/j.nima.2006.05.248

APA

Fox, H., Abazov, V. M., Abbott, M., & Abolins, M. (2006). The Upgraded D0 detector. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 565(2), 463-537. https://doi.org/10.1016/j.nima.2006.05.248

Vancouver

Fox H, Abazov VM, Abbott M, Abolins M. The Upgraded D0 detector. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 2006 Sept 15;565(2):463-537. doi: 10.1016/j.nima.2006.05.248

Author

Fox, H. ; Abazov, V. M. ; Abbott, M. et al. / The Upgraded D0 detector. In: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 2006 ; Vol. 565, No. 2. pp. 463-537.

Bibtex

@article{1c2bfe9014504905b0feb5e5d7c3e406,
title = "The Upgraded D0 detector.",
abstract = "The D{\O} experiment enjoyed a very successful data-collection run at the Fermilab Tevatron collider between 1992 and 1996. Since then, the detector has been upgraded to take advantage of improvements to the Tevatron and to enhance its physics capabilities. We describe the new elements of the detector, including the silicon microstrip tracker, central fiber tracker, solenoidal magnet, preshower detectors, forward muon detector, and forward proton detector. The uranium/liquid-argon calorimeters and central muon detector, remaining from Run I, are discussed briefly. We also present the associated electronics, triggering, and data acquisition systems, along with the design and implementation of software specific to D{\O}.",
keywords = "Fermilab, DZero, D0, Tevatron Run II",
author = "H. Fox and Abazov, {V. M.} and M. Abbott and M. Abolins",
note = "Fox was one of the chief contributors to the commissioning of the Silicon Microstrip detector of the D-Zero experiment, which is a crucial component in much of the physics, including the B physics results, presented in this submission. 135 citations (SPIRES). RAE_import_type : Journal article RAE_uoa_type : Physics",
year = "2006",
month = sep,
day = "15",
doi = "10.1016/j.nima.2006.05.248",
language = "English",
volume = "565",
pages = "463--537",
journal = "Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment",
issn = "0168-9002",
publisher = "ELSEVIER SCIENCE BV",
number = "2",

}

RIS

TY - JOUR

T1 - The Upgraded D0 detector.

AU - Fox, H.

AU - Abazov, V. M.

AU - Abbott, M.

AU - Abolins, M.

N1 - Fox was one of the chief contributors to the commissioning of the Silicon Microstrip detector of the D-Zero experiment, which is a crucial component in much of the physics, including the B physics results, presented in this submission. 135 citations (SPIRES). RAE_import_type : Journal article RAE_uoa_type : Physics

PY - 2006/9/15

Y1 - 2006/9/15

N2 - The DØ experiment enjoyed a very successful data-collection run at the Fermilab Tevatron collider between 1992 and 1996. Since then, the detector has been upgraded to take advantage of improvements to the Tevatron and to enhance its physics capabilities. We describe the new elements of the detector, including the silicon microstrip tracker, central fiber tracker, solenoidal magnet, preshower detectors, forward muon detector, and forward proton detector. The uranium/liquid-argon calorimeters and central muon detector, remaining from Run I, are discussed briefly. We also present the associated electronics, triggering, and data acquisition systems, along with the design and implementation of software specific to DØ.

AB - The DØ experiment enjoyed a very successful data-collection run at the Fermilab Tevatron collider between 1992 and 1996. Since then, the detector has been upgraded to take advantage of improvements to the Tevatron and to enhance its physics capabilities. We describe the new elements of the detector, including the silicon microstrip tracker, central fiber tracker, solenoidal magnet, preshower detectors, forward muon detector, and forward proton detector. The uranium/liquid-argon calorimeters and central muon detector, remaining from Run I, are discussed briefly. We also present the associated electronics, triggering, and data acquisition systems, along with the design and implementation of software specific to DØ.

KW - Fermilab

KW - DZero

KW - D0

KW - Tevatron Run II

U2 - 10.1016/j.nima.2006.05.248

DO - 10.1016/j.nima.2006.05.248

M3 - Journal article

VL - 565

SP - 463

EP - 537

JO - Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

JF - Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

SN - 0168-9002

IS - 2

ER -