Performance characteristics of a polyethylene collimator with an EJ-426 detector in neutron source localisation

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Published

Standard

Performance characteristics of a polyethylene collimator with an EJ-426 detector in neutron source localisation. / Gamage, Kelum; Crompton, Anita; Joyce, Malcolm.
In: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 755, 11.08.2014, p. 1-5.

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Harvard

Gamage, K, Crompton, A & Joyce, M 2014, 'Performance characteristics of a polyethylene collimator with an EJ-426 detector in neutron source localisation', Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, vol. 755, pp. 1-5. https://doi.org/10.1016/j.nima.2014.04.032

APA

Gamage, K., Crompton, A., & Joyce, M. (2014). Performance characteristics of a polyethylene collimator with an EJ-426 detector in neutron source localisation. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 755, 1-5. https://doi.org/10.1016/j.nima.2014.04.032

Vancouver

Gamage K, Crompton A, Joyce M. Performance characteristics of a polyethylene collimator with an EJ-426 detector in neutron source localisation. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 2014 Aug 11;755:1-5. doi: 10.1016/j.nima.2014.04.032

Author

Gamage, Kelum ; Crompton, Anita ; Joyce, Malcolm. / Performance characteristics of a polyethylene collimator with an EJ-426 detector in neutron source localisation. In: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 2014 ; Vol. 755. pp. 1-5.

Bibtex

@article{405160a465ec49339892f90cbb916db7,
title = "Performance characteristics of a polyethylene collimator with an EJ-426 detector in neutron source localisation",
abstract = "In this paper, characteristics of neutron source localisation using an EJ-426 detector with a polyethylene collimator are presented. The detector is placed inside of the polyethylene collimator, where the collimator has a constant internal diameter and external diameter gradually increases towards the back end. The combined detector-collimator unit was mounted onto an equatorial mount and, data were collected from an ultra-fast mixed-field analyser. Neutron images have been produced to characterise the area investigated in real-time. Radiation images are fundamentally related to the detector efficiency and to the collimator geometry. In order to characterise the neutron source localisation capability of the polyethylene collimator, with an EJ-426 detector, experiments have been carried out using three different neutron sources. Results indicate that the existing design of the polyethylene collimator is suitable for localisation of low energy neutron sources. The measurements were performed in the low-scatter facility of the Neutron Metrology, National Physical Laboratory, Teddington, UK.",
keywords = "Polyethylene collimator, EJ-426 detector , Ultra-fast mixed-field analyser , Real-time digital imaging analysis",
author = "Kelum Gamage and Anita Crompton and Malcolm Joyce",
year = "2014",
month = aug,
day = "11",
doi = "10.1016/j.nima.2014.04.032",
language = "English",
volume = "755",
pages = "1--5",
journal = "Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment",
issn = "0168-9002",
publisher = "ELSEVIER SCIENCE BV",

}

RIS

TY - JOUR

T1 - Performance characteristics of a polyethylene collimator with an EJ-426 detector in neutron source localisation

AU - Gamage, Kelum

AU - Crompton, Anita

AU - Joyce, Malcolm

PY - 2014/8/11

Y1 - 2014/8/11

N2 - In this paper, characteristics of neutron source localisation using an EJ-426 detector with a polyethylene collimator are presented. The detector is placed inside of the polyethylene collimator, where the collimator has a constant internal diameter and external diameter gradually increases towards the back end. The combined detector-collimator unit was mounted onto an equatorial mount and, data were collected from an ultra-fast mixed-field analyser. Neutron images have been produced to characterise the area investigated in real-time. Radiation images are fundamentally related to the detector efficiency and to the collimator geometry. In order to characterise the neutron source localisation capability of the polyethylene collimator, with an EJ-426 detector, experiments have been carried out using three different neutron sources. Results indicate that the existing design of the polyethylene collimator is suitable for localisation of low energy neutron sources. The measurements were performed in the low-scatter facility of the Neutron Metrology, National Physical Laboratory, Teddington, UK.

AB - In this paper, characteristics of neutron source localisation using an EJ-426 detector with a polyethylene collimator are presented. The detector is placed inside of the polyethylene collimator, where the collimator has a constant internal diameter and external diameter gradually increases towards the back end. The combined detector-collimator unit was mounted onto an equatorial mount and, data were collected from an ultra-fast mixed-field analyser. Neutron images have been produced to characterise the area investigated in real-time. Radiation images are fundamentally related to the detector efficiency and to the collimator geometry. In order to characterise the neutron source localisation capability of the polyethylene collimator, with an EJ-426 detector, experiments have been carried out using three different neutron sources. Results indicate that the existing design of the polyethylene collimator is suitable for localisation of low energy neutron sources. The measurements were performed in the low-scatter facility of the Neutron Metrology, National Physical Laboratory, Teddington, UK.

KW - Polyethylene collimator

KW - EJ-426 detector

KW - Ultra-fast mixed-field analyser

KW - Real-time digital imaging analysis