Home > Research > Publications & Outputs > A SYNCHROTRON X-RAY STUDY OF THE CHANGES OCCURR...
View graph of relations

A SYNCHROTRON X-RAY STUDY OF THE CHANGES OCCURRING IN THE CORNEAL STROMA DURING PROCESSING FOR ELECTRON-MICROSCOPY

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Published

Standard

A SYNCHROTRON X-RAY STUDY OF THE CHANGES OCCURRING IN THE CORNEAL STROMA DURING PROCESSING FOR ELECTRON-MICROSCOPY. / FULLWOOD, N J ; MEEK, K M .
In: Journal of Microscopy, Vol. 169, 01.1993, p. 53-60.

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Harvard

APA

Vancouver

Author

Bibtex

@article{2d393105255f42b980d3ff2b67383614,
title = "A SYNCHROTRON X-RAY STUDY OF THE CHANGES OCCURRING IN THE CORNEAL STROMA DURING PROCESSING FOR ELECTRON-MICROSCOPY",
abstract = "Using a high-intensity synchrotron X-ray source, the structural changes occurring in the corneal stroma were monitored during each stage of several different processing runs for the transmission electron microscope (TEM) and scanning electron microscope (SEM). The parameters studied were interfibrillar spacing, intermolecular spacing, D-periodicity and fibril diameter.The processing schedule that produced the least changes in spacings for TEM specimens involved extended fixation in glutaraldehyde followed by low-temperature embedding in Lowicryl K4M resin. However, interfibrillar material was better preserved after embedding in LR White resin or Nanoplast.Almost every processing stage for electron microscopy produced significant changes in one or more structural parameters in the cornea. Glutaraldehyde fixation significantly increased the intermolecular spacings, while resin infiltration and resin polymerization each resulted in shrinkage of all the spacings monitored. Critical-point drying for SEM specimens resulted in considerable shrinkage in all three spacings, but was still preferable to air drying, which caused reduction in the order of the fibril packing, resulting in loss of the interfibrillar X-ray pattern. Perhaps the most drastic effect was caused by post-fixation in osmium tetroxide, which resulted in loss of the intermolecular pattern, and also increased the amount of shrinkage in the interfibrillar spacings and the D-periodicity which occurred during later stages of processing.",
keywords = "CORNEA, X-RAY SYNCHROTRON, ELECTRON MICROSCOPY, PREPARATION, RESINS, COLLAGEN FIBRILS",
author = "FULLWOOD, {N J} and MEEK, {K M}",
year = "1993",
month = jan,
language = "English",
volume = "169",
pages = "53--60",
journal = "Journal of Microscopy",
issn = "0022-2720",
publisher = "Wiley-Blackwell",

}

RIS

TY - JOUR

T1 - A SYNCHROTRON X-RAY STUDY OF THE CHANGES OCCURRING IN THE CORNEAL STROMA DURING PROCESSING FOR ELECTRON-MICROSCOPY

AU - FULLWOOD, N J

AU - MEEK, K M

PY - 1993/1

Y1 - 1993/1

N2 - Using a high-intensity synchrotron X-ray source, the structural changes occurring in the corneal stroma were monitored during each stage of several different processing runs for the transmission electron microscope (TEM) and scanning electron microscope (SEM). The parameters studied were interfibrillar spacing, intermolecular spacing, D-periodicity and fibril diameter.The processing schedule that produced the least changes in spacings for TEM specimens involved extended fixation in glutaraldehyde followed by low-temperature embedding in Lowicryl K4M resin. However, interfibrillar material was better preserved after embedding in LR White resin or Nanoplast.Almost every processing stage for electron microscopy produced significant changes in one or more structural parameters in the cornea. Glutaraldehyde fixation significantly increased the intermolecular spacings, while resin infiltration and resin polymerization each resulted in shrinkage of all the spacings monitored. Critical-point drying for SEM specimens resulted in considerable shrinkage in all three spacings, but was still preferable to air drying, which caused reduction in the order of the fibril packing, resulting in loss of the interfibrillar X-ray pattern. Perhaps the most drastic effect was caused by post-fixation in osmium tetroxide, which resulted in loss of the intermolecular pattern, and also increased the amount of shrinkage in the interfibrillar spacings and the D-periodicity which occurred during later stages of processing.

AB - Using a high-intensity synchrotron X-ray source, the structural changes occurring in the corneal stroma were monitored during each stage of several different processing runs for the transmission electron microscope (TEM) and scanning electron microscope (SEM). The parameters studied were interfibrillar spacing, intermolecular spacing, D-periodicity and fibril diameter.The processing schedule that produced the least changes in spacings for TEM specimens involved extended fixation in glutaraldehyde followed by low-temperature embedding in Lowicryl K4M resin. However, interfibrillar material was better preserved after embedding in LR White resin or Nanoplast.Almost every processing stage for electron microscopy produced significant changes in one or more structural parameters in the cornea. Glutaraldehyde fixation significantly increased the intermolecular spacings, while resin infiltration and resin polymerization each resulted in shrinkage of all the spacings monitored. Critical-point drying for SEM specimens resulted in considerable shrinkage in all three spacings, but was still preferable to air drying, which caused reduction in the order of the fibril packing, resulting in loss of the interfibrillar X-ray pattern. Perhaps the most drastic effect was caused by post-fixation in osmium tetroxide, which resulted in loss of the intermolecular pattern, and also increased the amount of shrinkage in the interfibrillar spacings and the D-periodicity which occurred during later stages of processing.

KW - CORNEA

KW - X-RAY SYNCHROTRON

KW - ELECTRON MICROSCOPY

KW - PREPARATION

KW - RESINS

KW - COLLAGEN FIBRILS

M3 - Journal article

VL - 169

SP - 53

EP - 60

JO - Journal of Microscopy

JF - Journal of Microscopy

SN - 0022-2720

ER -