Home > Research > Publications & Outputs > An electrochemical label-free DNA impedimetric ...

Links

Text available via DOI:

View graph of relations

An electrochemical label-free DNA impedimetric sensor with AuNP-modified glass fiber/carbonaceous electrode for the detection of HIV-1 DNA

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Published

Standard

An electrochemical label-free DNA impedimetric sensor with AuNP-modified glass fiber/carbonaceous electrode for the detection of HIV-1 DNA. / Yeter, Ece; Şahin, Samet; Caglayan, M. Oguzhan et al.
In: Chemical Papers, Vol. 75, No. 1, 31.01.2021, p. 77-87.

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Harvard

APA

Vancouver

Yeter E, Şahin S, Caglayan MO, Üstündağ Z. An electrochemical label-free DNA impedimetric sensor with AuNP-modified glass fiber/carbonaceous electrode for the detection of HIV-1 DNA. Chemical Papers. 2021 Jan 31;75(1):77-87. doi: 10.1007/s11696-020-01280-5

Author

Bibtex

@article{5554f04133cd49e2b0454792ab2af6a9,
title = "An electrochemical label-free DNA impedimetric sensor with AuNP-modified glass fiber/carbonaceous electrode for the detection of HIV-1 DNA",
abstract = "In this study, a highly sensitive, electrochemical, and label-free DNA impedimetric sensor was developed using carbonized glass fiber–coal tar pitch (GF–CTP) electrodes supported with gold nanoparticles (AuNPs) for the detection of HIV-1 gene. Thiol-modified GF–CTP electrodes were prepared using amine crosslinking chemistry and AuNPs were self-assembled obtaining highly conductive nanoelectrodes, GF–CTP–ATP–Au. All steps of electrode modifications were characterized using electrochemical, spectroscopic, and microscopic methods. GF–CTP–ATP–Au electrode was then modified with a capture DNA probe (C-ssDNA) and optimized with a target DNA probe in terms of hybridization time and temperature between 30 and 180 min and 20–50 °C, respectively. Finally, the analytic performance of the developed ssDNA biosensor was evaluated using electrochemical impedance spectroscopy. The calibration of the sensor was obtained between 0.1 pM and 10 nM analyte working range. The limit of detection was calculated using signal to noise ratio of 3 (S/N = 3) as 13 fM. Moreover, interference results for two noncomplementary DNA probes were also tested to demonstrate non-specific ssDNA interactions. An electrochemical label-free DNA impedimetric sensor was successfully developed using a novel GF–CTP–ATP–Au electrode. This study suggests that highly sensitive DNA-based biosensors can be developed using relatively low-cost carbonaceous materials.",
keywords = "Carbonaceous materials, Coal tar pitch, DNA sensor, HIV-1, Impedimetric sensor",
author = "Ece Yeter and Samet {\c S}ahin and Caglayan, {M. Oguzhan} and Zafer {\"U}st{\"u}ndağ",
year = "2021",
month = jan,
day = "31",
doi = "10.1007/s11696-020-01280-5",
language = "English",
volume = "75",
pages = "77--87",
journal = "Chemical Papers",
issn = "0366-6352",
publisher = "Springer International Publishing AG",
number = "1",

}

RIS

TY - JOUR

T1 - An electrochemical label-free DNA impedimetric sensor with AuNP-modified glass fiber/carbonaceous electrode for the detection of HIV-1 DNA

AU - Yeter, Ece

AU - Şahin, Samet

AU - Caglayan, M. Oguzhan

AU - Üstündağ, Zafer

PY - 2021/1/31

Y1 - 2021/1/31

N2 - In this study, a highly sensitive, electrochemical, and label-free DNA impedimetric sensor was developed using carbonized glass fiber–coal tar pitch (GF–CTP) electrodes supported with gold nanoparticles (AuNPs) for the detection of HIV-1 gene. Thiol-modified GF–CTP electrodes were prepared using amine crosslinking chemistry and AuNPs were self-assembled obtaining highly conductive nanoelectrodes, GF–CTP–ATP–Au. All steps of electrode modifications were characterized using electrochemical, spectroscopic, and microscopic methods. GF–CTP–ATP–Au electrode was then modified with a capture DNA probe (C-ssDNA) and optimized with a target DNA probe in terms of hybridization time and temperature between 30 and 180 min and 20–50 °C, respectively. Finally, the analytic performance of the developed ssDNA biosensor was evaluated using electrochemical impedance spectroscopy. The calibration of the sensor was obtained between 0.1 pM and 10 nM analyte working range. The limit of detection was calculated using signal to noise ratio of 3 (S/N = 3) as 13 fM. Moreover, interference results for two noncomplementary DNA probes were also tested to demonstrate non-specific ssDNA interactions. An electrochemical label-free DNA impedimetric sensor was successfully developed using a novel GF–CTP–ATP–Au electrode. This study suggests that highly sensitive DNA-based biosensors can be developed using relatively low-cost carbonaceous materials.

AB - In this study, a highly sensitive, electrochemical, and label-free DNA impedimetric sensor was developed using carbonized glass fiber–coal tar pitch (GF–CTP) electrodes supported with gold nanoparticles (AuNPs) for the detection of HIV-1 gene. Thiol-modified GF–CTP electrodes were prepared using amine crosslinking chemistry and AuNPs were self-assembled obtaining highly conductive nanoelectrodes, GF–CTP–ATP–Au. All steps of electrode modifications were characterized using electrochemical, spectroscopic, and microscopic methods. GF–CTP–ATP–Au electrode was then modified with a capture DNA probe (C-ssDNA) and optimized with a target DNA probe in terms of hybridization time and temperature between 30 and 180 min and 20–50 °C, respectively. Finally, the analytic performance of the developed ssDNA biosensor was evaluated using electrochemical impedance spectroscopy. The calibration of the sensor was obtained between 0.1 pM and 10 nM analyte working range. The limit of detection was calculated using signal to noise ratio of 3 (S/N = 3) as 13 fM. Moreover, interference results for two noncomplementary DNA probes were also tested to demonstrate non-specific ssDNA interactions. An electrochemical label-free DNA impedimetric sensor was successfully developed using a novel GF–CTP–ATP–Au electrode. This study suggests that highly sensitive DNA-based biosensors can be developed using relatively low-cost carbonaceous materials.

KW - Carbonaceous materials

KW - Coal tar pitch

KW - DNA sensor

KW - HIV-1

KW - Impedimetric sensor

U2 - 10.1007/s11696-020-01280-5

DO - 10.1007/s11696-020-01280-5

M3 - Journal article

AN - SCOPUS:85087769796

VL - 75

SP - 77

EP - 87

JO - Chemical Papers

JF - Chemical Papers

SN - 0366-6352

IS - 1

ER -