Home > Research > Publications & Outputs > APPLICATION OF PASSIVE SAMPLERS TO THE MONITORI...
View graph of relations

APPLICATION OF PASSIVE SAMPLERS TO THE MONITORING OF LOW CONCENTRATION ORGANIC VAPORS IN INDOOR AND AMBIENT AIR - A REVIEW

Research output: Contribution to Journal/MagazineLiterature reviewpeer-review

Published

Standard

APPLICATION OF PASSIVE SAMPLERS TO THE MONITORING OF LOW CONCENTRATION ORGANIC VAPORS IN INDOOR AND AMBIENT AIR - A REVIEW. / CAO, X L ; Hewitt, C. N.
In: Environmental Technology, Vol. 12, No. 11, 11.1991, p. 1055-1062.

Research output: Contribution to Journal/MagazineLiterature reviewpeer-review

Harvard

APA

Vancouver

Author

Bibtex

@article{a0ba5d77c4d44af4a5afc452958519c8,
title = "APPLICATION OF PASSIVE SAMPLERS TO THE MONITORING OF LOW CONCENTRATION ORGANIC VAPORS IN INDOOR AND AMBIENT AIR - A REVIEW",
abstract = "This paper presents a review of the recent application of passive samplers for the sampling of low concentration organic vapours in indoor and ambient air. Theoretical equations describing the operation of various types of passive samplers are summarized. The problems associated with the application of passive samplers for the sampling of organic vapours in indoor and ambient air, and the factors affecting the performance of passive samplers are discussed. It is suggested the effective cross-sectional area be employed in calculating the diffusion uptake rate according to DA/L instead of the total cross-sectional area. It is further suggested that suitable passive samplers with a higher uptake rate should be designed (e.g. by reducing the diffusion length), and a new and simple validation procedure should be developed for their application in indoor and ambient air environments.",
keywords = "PASSIVE SAMPLERS, LOW CONCENTRATION, ORGANIC VAPORS, INDOOR AIR, AMBIENT AIR, DIFFUSIVE SAMPLER, PERFORMANCE, POLLUTANTS, PERMEATION, VAPORS, ACRYLONITRILE, DOSIMETERS",
author = "CAO, {X L} and Hewitt, {C. N.}",
year = "1991",
month = nov,
language = "English",
volume = "12",
pages = "1055--1062",
journal = "Environmental Technology",
issn = "0959-3330",
publisher = "Taylor and Francis Ltd.",
number = "11",

}

RIS

TY - JOUR

T1 - APPLICATION OF PASSIVE SAMPLERS TO THE MONITORING OF LOW CONCENTRATION ORGANIC VAPORS IN INDOOR AND AMBIENT AIR - A REVIEW

AU - CAO, X L

AU - Hewitt, C. N.

PY - 1991/11

Y1 - 1991/11

N2 - This paper presents a review of the recent application of passive samplers for the sampling of low concentration organic vapours in indoor and ambient air. Theoretical equations describing the operation of various types of passive samplers are summarized. The problems associated with the application of passive samplers for the sampling of organic vapours in indoor and ambient air, and the factors affecting the performance of passive samplers are discussed. It is suggested the effective cross-sectional area be employed in calculating the diffusion uptake rate according to DA/L instead of the total cross-sectional area. It is further suggested that suitable passive samplers with a higher uptake rate should be designed (e.g. by reducing the diffusion length), and a new and simple validation procedure should be developed for their application in indoor and ambient air environments.

AB - This paper presents a review of the recent application of passive samplers for the sampling of low concentration organic vapours in indoor and ambient air. Theoretical equations describing the operation of various types of passive samplers are summarized. The problems associated with the application of passive samplers for the sampling of organic vapours in indoor and ambient air, and the factors affecting the performance of passive samplers are discussed. It is suggested the effective cross-sectional area be employed in calculating the diffusion uptake rate according to DA/L instead of the total cross-sectional area. It is further suggested that suitable passive samplers with a higher uptake rate should be designed (e.g. by reducing the diffusion length), and a new and simple validation procedure should be developed for their application in indoor and ambient air environments.

KW - PASSIVE SAMPLERS

KW - LOW CONCENTRATION

KW - ORGANIC VAPORS

KW - INDOOR AIR

KW - AMBIENT AIR

KW - DIFFUSIVE SAMPLER

KW - PERFORMANCE

KW - POLLUTANTS

KW - PERMEATION

KW - VAPORS

KW - ACRYLONITRILE

KW - DOSIMETERS

M3 - Literature review

VL - 12

SP - 1055

EP - 1062

JO - Environmental Technology

JF - Environmental Technology

SN - 0959-3330

IS - 11

ER -