Home > Research > Publications & Outputs > Artefacts at the liquid interface and their imp...

Links

Text available via DOI:

View graph of relations

Artefacts at the liquid interface and their impact in miniaturized biochemical assay

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Published

Standard

Artefacts at the liquid interface and their impact in miniaturized biochemical assay. / Litten, Brett; Blackett, Carolyn; Wigglesworth, Mark et al.
In: Biomicrofluidics, Vol. 9, No. 5, 052607, 09.2015.

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Harvard

Litten, B, Blackett, C, Wigglesworth, M, Goddard, N & Fielden, P 2015, 'Artefacts at the liquid interface and their impact in miniaturized biochemical assay', Biomicrofluidics, vol. 9, no. 5, 052607. https://doi.org/10.1063/1.4927324

APA

Litten, B., Blackett, C., Wigglesworth, M., Goddard, N., & Fielden, P. (2015). Artefacts at the liquid interface and their impact in miniaturized biochemical assay. Biomicrofluidics, 9(5), Article 052607. https://doi.org/10.1063/1.4927324

Vancouver

Litten B, Blackett C, Wigglesworth M, Goddard N, Fielden P. Artefacts at the liquid interface and their impact in miniaturized biochemical assay. Biomicrofluidics. 2015 Sept;9(5):052607. doi: 10.1063/1.4927324

Author

Litten, Brett ; Blackett, Carolyn ; Wigglesworth, Mark et al. / Artefacts at the liquid interface and their impact in miniaturized biochemical assay. In: Biomicrofluidics. 2015 ; Vol. 9, No. 5.

Bibtex

@article{10dc9190d7a04838b7b722056fe9fdc3,
title = "Artefacts at the liquid interface and their impact in miniaturized biochemical assay",
abstract = "Droplet microfluidic technology has the potential to significantly reduce reagent use, and therefore, lower costs of assays employed in drug discovery campaigns. In addition to the reduction in costs, this technology can also reduce evaporation and contamination which are often problems seen in miniaturized microtitre plate formats. Despite these advantages, we currently advise caution in the use of these microfluidic approaches as there remains a lack of understanding of the artefacts of the systems such as reagent partitioning from droplet to carrier oil and interaction of the biological reagents with the water-oil interface. Both types of artefact can lead to inaccurate and misleading data. In this paper, we present a study of the partitioning of a number of drug-like molecules in a range of oils and evidence of protein binding at the water-oil interface which results in reduced activity of a cytochrome P450 enzyme. Data presented show that the drug-like molecules partitioned the least into fluorocarbon oils and the interaction of the 1A2 cytochrome at the water-oil interface resulted in a lower or complete absence of enzyme activity. This loss of activity of cytochrome 1A2 could be restored by the use of secondary blocking proteins although changes in the pharmacology of known 1A2 inhibitors were observed. The artefacts described here due to reagents partitioning into the carrier oil or protein binding at the water-oil interface significantly impact the potential use of these microfluidic systems as a means to carry out miniaturized biological assays, and further work is needed to understand the impact and reduction of these phenomena. (C) 2015 AIP Publishing LLC.",
keywords = "CYTOCHROME-P450 INHIBITION, MICROFLUIDICS, ELECTROFUSION, RETENTION, DEVICE",
author = "Brett Litten and Carolyn Blackett and Mark Wigglesworth and Nicholas Goddard and Peter Fielden",
year = "2015",
month = sep,
doi = "10.1063/1.4927324",
language = "English",
volume = "9",
journal = "Biomicrofluidics",
issn = "1932-1058",
publisher = "AMER INST PHYSICS",
number = "5",

}

RIS

TY - JOUR

T1 - Artefacts at the liquid interface and their impact in miniaturized biochemical assay

AU - Litten, Brett

AU - Blackett, Carolyn

AU - Wigglesworth, Mark

AU - Goddard, Nicholas

AU - Fielden, Peter

PY - 2015/9

Y1 - 2015/9

N2 - Droplet microfluidic technology has the potential to significantly reduce reagent use, and therefore, lower costs of assays employed in drug discovery campaigns. In addition to the reduction in costs, this technology can also reduce evaporation and contamination which are often problems seen in miniaturized microtitre plate formats. Despite these advantages, we currently advise caution in the use of these microfluidic approaches as there remains a lack of understanding of the artefacts of the systems such as reagent partitioning from droplet to carrier oil and interaction of the biological reagents with the water-oil interface. Both types of artefact can lead to inaccurate and misleading data. In this paper, we present a study of the partitioning of a number of drug-like molecules in a range of oils and evidence of protein binding at the water-oil interface which results in reduced activity of a cytochrome P450 enzyme. Data presented show that the drug-like molecules partitioned the least into fluorocarbon oils and the interaction of the 1A2 cytochrome at the water-oil interface resulted in a lower or complete absence of enzyme activity. This loss of activity of cytochrome 1A2 could be restored by the use of secondary blocking proteins although changes in the pharmacology of known 1A2 inhibitors were observed. The artefacts described here due to reagents partitioning into the carrier oil or protein binding at the water-oil interface significantly impact the potential use of these microfluidic systems as a means to carry out miniaturized biological assays, and further work is needed to understand the impact and reduction of these phenomena. (C) 2015 AIP Publishing LLC.

AB - Droplet microfluidic technology has the potential to significantly reduce reagent use, and therefore, lower costs of assays employed in drug discovery campaigns. In addition to the reduction in costs, this technology can also reduce evaporation and contamination which are often problems seen in miniaturized microtitre plate formats. Despite these advantages, we currently advise caution in the use of these microfluidic approaches as there remains a lack of understanding of the artefacts of the systems such as reagent partitioning from droplet to carrier oil and interaction of the biological reagents with the water-oil interface. Both types of artefact can lead to inaccurate and misleading data. In this paper, we present a study of the partitioning of a number of drug-like molecules in a range of oils and evidence of protein binding at the water-oil interface which results in reduced activity of a cytochrome P450 enzyme. Data presented show that the drug-like molecules partitioned the least into fluorocarbon oils and the interaction of the 1A2 cytochrome at the water-oil interface resulted in a lower or complete absence of enzyme activity. This loss of activity of cytochrome 1A2 could be restored by the use of secondary blocking proteins although changes in the pharmacology of known 1A2 inhibitors were observed. The artefacts described here due to reagents partitioning into the carrier oil or protein binding at the water-oil interface significantly impact the potential use of these microfluidic systems as a means to carry out miniaturized biological assays, and further work is needed to understand the impact and reduction of these phenomena. (C) 2015 AIP Publishing LLC.

KW - CYTOCHROME-P450 INHIBITION

KW - MICROFLUIDICS

KW - ELECTROFUSION

KW - RETENTION

KW - DEVICE

U2 - 10.1063/1.4927324

DO - 10.1063/1.4927324

M3 - Journal article

VL - 9

JO - Biomicrofluidics

JF - Biomicrofluidics

SN - 1932-1058

IS - 5

M1 - 052607

ER -