Home > Research > Publications & Outputs > Battery energy storage systems providing dynami...

Electronic data

  • Paper IJEPES-D-24-00705.R1_clean

    Accepted author manuscript, 9.49 MB, PDF document

    Available under license: CC BY: Creative Commons Attribution 4.0 International License

Links

Text available via DOI:

View graph of relations

Battery energy storage systems providing dynamic containment frequency response service

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Published
  • Xihai Cao
  • Jan Engelhardt
  • Charalampos Ziras
  • Mattia Marinelli
  • Nan Zhao
Close
Article number110288
<mark>Journal publication date</mark>30/11/2024
<mark>Journal</mark>International Journal of Electrical Power & Energy Systems
Volume162
Publication StatusPublished
Early online date30/10/24
<mark>Original language</mark>English

Abstract

Battery energy storage systems (BESS) have emerged as a critical component in maintaining power system stability through frequency regulation. Their rapid response and flexible characteristics have generated considerable interest among researchers. This study focuses on the provision of a fast frequency response service, known as Dynamic Containment Frequency Response (DCFR), in Great Britain (GB). It conducts a detailed assessment of BESS-based DCFR service for frequency regulation and State-of-charge (SOC) management, including the configuration constraints set out by the energy recovery rules and SOC management impact. A methodology is presented to investigate the performance of DCFR-based BESS in a power system, alongside a stability analysis focusing on the impact of the SOC management mechanism. The stability study investigates the potential influential factors of battery SOC management when providing DCFR via root locus. For simulation case studies, a power imbalance estimation method is utilized for gaining the input. Based on the stability analysis results, key BESS configuration parameters are examined in an integrated power system model: C-rate, SOC management range, ratio and target. Another influential factor, SOC management time delay, is also analyzed. Finally, a comparison between DCFR and the previous frequency regulation service, Enhanced Frequency Response (EFR), is conducted. The study reveals that improper SOC management in DCFR can lead to SOC oscillation, adversely affecting performance. However, with proper configuration, DCFR offers more favorable outcomes than EFR in terms of frequency quality, SOC levels, and battery degradation.