Development and Performance of the Diffusive Gradients in Thin-Films Technique for the Measurement of Technetium-99 in Seawater.

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Published

Standard

Development and Performance of the Diffusive Gradients in Thin-Films Technique for the Measurement of Technetium-99 in Seawater. / French, M.A.; Zhang, H.; Pates, Jackie M. et al.
In: Analytical Chemistry, Vol. 77, No. 1, 01.01.2005, p. 135-139.

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Harvard

APA

Vancouver

French MA, Zhang H, Pates JM, Bryan SE, Wilson RC. Development and Performance of the Diffusive Gradients in Thin-Films Technique for the Measurement of Technetium-99 in Seawater. Analytical Chemistry. 2005 Jan 1;77(1):135-139. doi: 10.1021/ac048774b

Author

Bibtex

@article{4cbd830f7f794bae8c1a7cb950909577,
title = "Development and Performance of the Diffusive Gradients in Thin-Films Technique for the Measurement of Technetium-99 in Seawater.",
abstract = "A novel technique for obtaining time-integrated 99Tc concentrations in seawater has been developed, using diffusive gradients in thin films (DGT). The performance of TEVA resin as a binding agent for 99Tc was investigated via laboratory experiments. The accumulated 99Tc activity per unit area of resin-gel was proportional to both the bulk solution activity and the exposure time for deployments of up to 2 weeks. The response of DGT was found to be independent of solution chemistries over the pH range 3-8 and ionic strength range 0.01-1.3 M. Seawater has pH 8 and ionic strength of approx. 0.7 M; therefore, the potential of the technique for field deployment in seawater was demonstrated. Detection limits of 0.05 and 0.025 Bq/L, for 2- and 4-week DGT deployments, respectively, were calculated for 99Tc measurement by liquid scintillation spectrometry. Using quadrupole ICPMS to measure bound 99Tc could reduce these detection limits to 0.125 mBq/L for a 4-week deployment. These detection limits are sufficiently low for monitoring contaminated environments, including the Irish Sea. This method is simpler and faster than other 99Tc analysis methods and represents the only means of obtaining timeintegrated data.",
keywords = "technetium-99 Irish Sea Diffusive Gradients in Thin films",
author = "M.A. French and H. Zhang and Pates, {Jackie M.} and S.E. Bryan and R.C. Wilson",
note = "Figures only available.",
year = "2005",
month = jan,
day = "1",
doi = "10.1021/ac048774b",
language = "English",
volume = "77",
pages = "135--139",
journal = "Analytical Chemistry",
issn = "0003-2700",
publisher = "American Chemical Society",
number = "1",

}

RIS

TY - JOUR

T1 - Development and Performance of the Diffusive Gradients in Thin-Films Technique for the Measurement of Technetium-99 in Seawater.

AU - French, M.A.

AU - Zhang, H.

AU - Pates, Jackie M.

AU - Bryan, S.E.

AU - Wilson, R.C.

N1 - Figures only available.

PY - 2005/1/1

Y1 - 2005/1/1

N2 - A novel technique for obtaining time-integrated 99Tc concentrations in seawater has been developed, using diffusive gradients in thin films (DGT). The performance of TEVA resin as a binding agent for 99Tc was investigated via laboratory experiments. The accumulated 99Tc activity per unit area of resin-gel was proportional to both the bulk solution activity and the exposure time for deployments of up to 2 weeks. The response of DGT was found to be independent of solution chemistries over the pH range 3-8 and ionic strength range 0.01-1.3 M. Seawater has pH 8 and ionic strength of approx. 0.7 M; therefore, the potential of the technique for field deployment in seawater was demonstrated. Detection limits of 0.05 and 0.025 Bq/L, for 2- and 4-week DGT deployments, respectively, were calculated for 99Tc measurement by liquid scintillation spectrometry. Using quadrupole ICPMS to measure bound 99Tc could reduce these detection limits to 0.125 mBq/L for a 4-week deployment. These detection limits are sufficiently low for monitoring contaminated environments, including the Irish Sea. This method is simpler and faster than other 99Tc analysis methods and represents the only means of obtaining timeintegrated data.

AB - A novel technique for obtaining time-integrated 99Tc concentrations in seawater has been developed, using diffusive gradients in thin films (DGT). The performance of TEVA resin as a binding agent for 99Tc was investigated via laboratory experiments. The accumulated 99Tc activity per unit area of resin-gel was proportional to both the bulk solution activity and the exposure time for deployments of up to 2 weeks. The response of DGT was found to be independent of solution chemistries over the pH range 3-8 and ionic strength range 0.01-1.3 M. Seawater has pH 8 and ionic strength of approx. 0.7 M; therefore, the potential of the technique for field deployment in seawater was demonstrated. Detection limits of 0.05 and 0.025 Bq/L, for 2- and 4-week DGT deployments, respectively, were calculated for 99Tc measurement by liquid scintillation spectrometry. Using quadrupole ICPMS to measure bound 99Tc could reduce these detection limits to 0.125 mBq/L for a 4-week deployment. These detection limits are sufficiently low for monitoring contaminated environments, including the Irish Sea. This method is simpler and faster than other 99Tc analysis methods and represents the only means of obtaining timeintegrated data.

KW - technetium-99 Irish Sea Diffusive Gradients in Thin films

U2 - 10.1021/ac048774b

DO - 10.1021/ac048774b

M3 - Journal article

VL - 77

SP - 135

EP - 139

JO - Analytical Chemistry

JF - Analytical Chemistry

SN - 0003-2700

IS - 1

ER -