Research output: Contribution to Journal/Magazine › Journal article › peer-review
Research output: Contribution to Journal/Magazine › Journal article › peer-review
}
TY - JOUR
T1 - Development of a linear array for intracavitary in vivo dosimetry during external beam radiotherapy and brachytherapy.
AU - Price, R. A.
AU - Benson, C.
AU - Joyce, Malcolm J.
AU - Rogers, K.
N1 - "©2004 IEEE. Personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works must be obtained from the IEEE." "This material is presented to ensure timely dissemination of scholarly and technical work. Copyright and all rights therein are retained by authors or by other copyright holders. All persons copying this information are expected to adhere to the terms and constraints invoked by each author's copyright. In most cases, these works may not be reposted without the explicit permission of the copyright holder."
PY - 2004
Y1 - 2004
N2 - We present the details of a new linear array dosimeter consisting of a chain of semiconductors mounted on an ultra-thin (50 μm thick) flexible substrate and housed in an intracavitary catheter. The semiconductors, manufactured by NMRC Cork, have not been packaging and incorporate a passivation layer that allows them to be mounted on the substrate using flip-chip-bonding. This paper reports, for the first time, the construction of a multiple (ten) detector array suited to in vivo dosimetry in the rectum, esophagus and vagina during external beam radiotherapy, as well as being adaptable to in vivo dosimetry during brachytherapy and diagnostic radiology.
AB - We present the details of a new linear array dosimeter consisting of a chain of semiconductors mounted on an ultra-thin (50 μm thick) flexible substrate and housed in an intracavitary catheter. The semiconductors, manufactured by NMRC Cork, have not been packaging and incorporate a passivation layer that allows them to be mounted on the substrate using flip-chip-bonding. This paper reports, for the first time, the construction of a multiple (ten) detector array suited to in vivo dosimetry in the rectum, esophagus and vagina during external beam radiotherapy, as well as being adaptable to in vivo dosimetry during brachytherapy and diagnostic radiology.
U2 - 10.1109/TNS.2004.832570
DO - 10.1109/TNS.2004.832570
M3 - Journal article
VL - 51
SP - 1420
EP - 1426
JO - IEEE Transactions on Nuclear Science
JF - IEEE Transactions on Nuclear Science
SN - 0018-9499
IS - 4
M1 - 8076167