Home > Research > Publications & Outputs > Development of a Quartz Crystal Microbalance se...

Electronic data

Text available via DOI:

View graph of relations

Development of a Quartz Crystal Microbalance sensor for the detection of Technetium in groundwater

Research output: ThesisDoctoral Thesis

Published

Standard

Development of a Quartz Crystal Microbalance sensor for the detection of Technetium in groundwater. / Papageorgiou, Athanasios.
Lancaster University, 2022. 199 p.

Research output: ThesisDoctoral Thesis

Harvard

APA

Vancouver

Papageorgiou A. Development of a Quartz Crystal Microbalance sensor for the detection of Technetium in groundwater. Lancaster University, 2022. 199 p. doi: 10.17635/lancaster/thesis/1787

Author

Bibtex

@phdthesis{ff194bc14869490ba41c0b22cc984100,
title = "Development of a Quartz Crystal Microbalance sensor for the detection of Technetium in groundwater",
abstract = "Technetium-99, a pure β-emitter with Emax =294 keV, is relatively long-lived radio isotope (t1/2 =2.1×105 y) found in nuclear waste, produced by the fission of U with a yield of 6%. Under normal environmental conditions, it is mostly encountered as the pertechnetate ion, TcO4-, which is highly soluble in water and consequently mobile in natural environment. For this reason, and because it often is the first radioisotope that can be detected in contamination scenarios, its monitoring into groundwater is a statutory requirement for every nuclear license site. Current determination methods of 99Tc involve several steps, such as chemical separation from the matrix, purification and source preparation, prior to radiometric (e.g. liquid scintillation counting) or mass spectroscopic (e.g. inductively coupled plasma mass spectroscopy) determination, due toits relatively low concentration in environmental samples, even in contaminationscenarios. The detection of 99Tc may take up to several days, thus making thesetechniques inappropriate for an emergency situation, where real-time monitoring is ideally required. Hence, in this work the development of a sensor for the real time monitoring of 99Tc in groundwater based on the Quartz Crystal Microbalance (QCM) is presented. The QCM is a piezoelectric resonator, which oscillates in a resonant frequency fs when an electric potential is applied across its body. It is capable of measuring very small changes in mass at its surface, through the change of the resonant frequency. The QCM is modified to respond exclusively to the presence of TcO4-, by application of materials reported in the literature for the effective take-up of Tc, such as TREN ligand, TEVA resin and a Ag-4,4bipyridine metal-organic framework. These materials are chemically modified in order to create effective coatings on the surface of the QCM, thusdeveloping novel ligands and films. The structures of these novel materials arecharacterised by several techniques such as and NMR, IR, MS, XRD and SEM and their response and selectivity is evaluated by monitoring the changes in the resonant frequency of the QCM as a function of the concentration of ReO4-, which is a non-radioactive chemical surrogate for TcO4-. Finally, the adsorption of ReO4- and other interferences is modelled with adsorption isotherms such as Langmuir, Freundlich and Sips. Adsorption experiments were conducted with NaReO4, NaCl, Na2SO4 and Na2CO3 and it was foundthat self-assembled monolayers of the TREN ligand and the active component of TEVA resin, Aliquat-336, did not yield any adsorption results, possibly because ReO4- is too light to be detected by a single monolayer. On the other hand, a multi-layered thin film of the Ag-4,4bipyridine metal-organic framework yielded adequate adsorption results; however, through the analysis with adsorption isotherms, it was found that Na+ cations where adsorbed in the thin film, rather than ReO4- anions, possibly through cation-π interactions.",
author = "Athanasios Papageorgiou",
year = "2022",
month = mar,
day = "28",
doi = "10.17635/lancaster/thesis/1787",
language = "English",
publisher = "Lancaster University",
school = "Lancaster University",

}

RIS

TY - BOOK

T1 - Development of a Quartz Crystal Microbalance sensor for the detection of Technetium in groundwater

AU - Papageorgiou, Athanasios

PY - 2022/3/28

Y1 - 2022/3/28

N2 - Technetium-99, a pure β-emitter with Emax =294 keV, is relatively long-lived radio isotope (t1/2 =2.1×105 y) found in nuclear waste, produced by the fission of U with a yield of 6%. Under normal environmental conditions, it is mostly encountered as the pertechnetate ion, TcO4-, which is highly soluble in water and consequently mobile in natural environment. For this reason, and because it often is the first radioisotope that can be detected in contamination scenarios, its monitoring into groundwater is a statutory requirement for every nuclear license site. Current determination methods of 99Tc involve several steps, such as chemical separation from the matrix, purification and source preparation, prior to radiometric (e.g. liquid scintillation counting) or mass spectroscopic (e.g. inductively coupled plasma mass spectroscopy) determination, due toits relatively low concentration in environmental samples, even in contaminationscenarios. The detection of 99Tc may take up to several days, thus making thesetechniques inappropriate for an emergency situation, where real-time monitoring is ideally required. Hence, in this work the development of a sensor for the real time monitoring of 99Tc in groundwater based on the Quartz Crystal Microbalance (QCM) is presented. The QCM is a piezoelectric resonator, which oscillates in a resonant frequency fs when an electric potential is applied across its body. It is capable of measuring very small changes in mass at its surface, through the change of the resonant frequency. The QCM is modified to respond exclusively to the presence of TcO4-, by application of materials reported in the literature for the effective take-up of Tc, such as TREN ligand, TEVA resin and a Ag-4,4bipyridine metal-organic framework. These materials are chemically modified in order to create effective coatings on the surface of the QCM, thusdeveloping novel ligands and films. The structures of these novel materials arecharacterised by several techniques such as and NMR, IR, MS, XRD and SEM and their response and selectivity is evaluated by monitoring the changes in the resonant frequency of the QCM as a function of the concentration of ReO4-, which is a non-radioactive chemical surrogate for TcO4-. Finally, the adsorption of ReO4- and other interferences is modelled with adsorption isotherms such as Langmuir, Freundlich and Sips. Adsorption experiments were conducted with NaReO4, NaCl, Na2SO4 and Na2CO3 and it was foundthat self-assembled monolayers of the TREN ligand and the active component of TEVA resin, Aliquat-336, did not yield any adsorption results, possibly because ReO4- is too light to be detected by a single monolayer. On the other hand, a multi-layered thin film of the Ag-4,4bipyridine metal-organic framework yielded adequate adsorption results; however, through the analysis with adsorption isotherms, it was found that Na+ cations where adsorbed in the thin film, rather than ReO4- anions, possibly through cation-π interactions.

AB - Technetium-99, a pure β-emitter with Emax =294 keV, is relatively long-lived radio isotope (t1/2 =2.1×105 y) found in nuclear waste, produced by the fission of U with a yield of 6%. Under normal environmental conditions, it is mostly encountered as the pertechnetate ion, TcO4-, which is highly soluble in water and consequently mobile in natural environment. For this reason, and because it often is the first radioisotope that can be detected in contamination scenarios, its monitoring into groundwater is a statutory requirement for every nuclear license site. Current determination methods of 99Tc involve several steps, such as chemical separation from the matrix, purification and source preparation, prior to radiometric (e.g. liquid scintillation counting) or mass spectroscopic (e.g. inductively coupled plasma mass spectroscopy) determination, due toits relatively low concentration in environmental samples, even in contaminationscenarios. The detection of 99Tc may take up to several days, thus making thesetechniques inappropriate for an emergency situation, where real-time monitoring is ideally required. Hence, in this work the development of a sensor for the real time monitoring of 99Tc in groundwater based on the Quartz Crystal Microbalance (QCM) is presented. The QCM is a piezoelectric resonator, which oscillates in a resonant frequency fs when an electric potential is applied across its body. It is capable of measuring very small changes in mass at its surface, through the change of the resonant frequency. The QCM is modified to respond exclusively to the presence of TcO4-, by application of materials reported in the literature for the effective take-up of Tc, such as TREN ligand, TEVA resin and a Ag-4,4bipyridine metal-organic framework. These materials are chemically modified in order to create effective coatings on the surface of the QCM, thusdeveloping novel ligands and films. The structures of these novel materials arecharacterised by several techniques such as and NMR, IR, MS, XRD and SEM and their response and selectivity is evaluated by monitoring the changes in the resonant frequency of the QCM as a function of the concentration of ReO4-, which is a non-radioactive chemical surrogate for TcO4-. Finally, the adsorption of ReO4- and other interferences is modelled with adsorption isotherms such as Langmuir, Freundlich and Sips. Adsorption experiments were conducted with NaReO4, NaCl, Na2SO4 and Na2CO3 and it was foundthat self-assembled monolayers of the TREN ligand and the active component of TEVA resin, Aliquat-336, did not yield any adsorption results, possibly because ReO4- is too light to be detected by a single monolayer. On the other hand, a multi-layered thin film of the Ag-4,4bipyridine metal-organic framework yielded adequate adsorption results; however, through the analysis with adsorption isotherms, it was found that Na+ cations where adsorbed in the thin film, rather than ReO4- anions, possibly through cation-π interactions.

U2 - 10.17635/lancaster/thesis/1787

DO - 10.17635/lancaster/thesis/1787

M3 - Doctoral Thesis

PB - Lancaster University

ER -