Home > Research > Publications & Outputs > Disposable electrochemical flow cells for catal...

Associated organisational unit

Electronic data

  • art_3A10.1007_2Fs00216_008_1948_5

    Rights statement: This article is distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and source are credited.

    Final published version, 317 KB, PDF document

    Available under license: CC BY-NC

Links

Text available via DOI:

View graph of relations

Disposable electrochemical flow cells for catalytic adsorptive stripping voltammetry (CAdSV) at a bismuth film electrode (BiFE)

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Published

Standard

Disposable electrochemical flow cells for catalytic adsorptive stripping voltammetry (CAdSV) at a bismuth film electrode (BiFE). / Naseri, Nahid Gharib; Baldock, Sara J.; Economou, Anastasios et al.
In: Analytical and Bioanalytical Chemistry, Vol. 391, No. 4, 06.2008, p. 1283-1292.

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Harvard

APA

Vancouver

Naseri NG, Baldock SJ, Economou A, Goddard NJ, Fielden PR. Disposable electrochemical flow cells for catalytic adsorptive stripping voltammetry (CAdSV) at a bismuth film electrode (BiFE). Analytical and Bioanalytical Chemistry. 2008 Jun;391(4):1283-1292. Epub 2008 Mar 20. doi: 10.1007/s00216-008-1948-5

Author

Naseri, Nahid Gharib ; Baldock, Sara J. ; Economou, Anastasios et al. / Disposable electrochemical flow cells for catalytic adsorptive stripping voltammetry (CAdSV) at a bismuth film electrode (BiFE). In: Analytical and Bioanalytical Chemistry. 2008 ; Vol. 391, No. 4. pp. 1283-1292.

Bibtex

@article{1bd1363d109a49bf8e0a91aced16f86f,
title = "Disposable electrochemical flow cells for catalytic adsorptive stripping voltammetry (CAdSV) at a bismuth film electrode (BiFE)",
abstract = "Catalytic adsorptive stripping voltammetry (CAdSV) has been demonstrated at a bismuth film electrode (BiFE) in an injection-moulded electrochemical micro-flow cell. The polystyrene three-electrode flow cell was fabricated with electrodes moulded from a conducting grade of polystyrene containing 40% carbon fibre, one of which was precoated with Ag to enable its use as an on-chip Ag/AgCl reference electrode. CAdSV of Co(II) and Ni(II) in the presence of dimethylglyoxime (DMG) with nitrite employed as the catalyst was performed in order to assess the performance of the flow cell with an in-line plated BiFE. The injection-moulded electrodes were found to be suitable substrates for the formation of BiFEs. Key parameters such as the plating solution matrix, plating flow rate, analysis flow rate, solution composition and square-wave parameters have been characterised and optimal conditions selected for successful and rapid analysis of Co(II) and Ni(II) at the ppb level. The analytical response was linear over the range 1 to 20 ppb and deoxygenation of the sample solution was not required. The successful coupling of a microfluidic flow cell with a BiFE, thereby forming a “mercury-free” AdSV flow analysis sensor, shows promise for industrial and in-the-field applications where inexpensive, compact, and robust instrumentation capable of low-volume analysis is required.",
keywords = "Bismuth film electrode (BiFE) , Square-wave adsorptive stripping voltammetry , Cobalt, Nickel, Dimethylglyoxime, Electrochemical detection, Flow cell , Channel, Injection moulding, Sensor",
author = "Naseri, {Nahid Gharib} and Baldock, {Sara J.} and Anastasios Economou and Goddard, {Nicholas J.} and Fielden, {Peter R.}",
note = "This article is distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and source are credited.",
year = "2008",
month = jun,
doi = "10.1007/s00216-008-1948-5",
language = "English",
volume = "391",
pages = "1283--1292",
journal = "Analytical and Bioanalytical Chemistry",
issn = "1618-2642",
publisher = "Springer Verlag",
number = "4",

}

RIS

TY - JOUR

T1 - Disposable electrochemical flow cells for catalytic adsorptive stripping voltammetry (CAdSV) at a bismuth film electrode (BiFE)

AU - Naseri, Nahid Gharib

AU - Baldock, Sara J.

AU - Economou, Anastasios

AU - Goddard, Nicholas J.

AU - Fielden, Peter R.

N1 - This article is distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and source are credited.

PY - 2008/6

Y1 - 2008/6

N2 - Catalytic adsorptive stripping voltammetry (CAdSV) has been demonstrated at a bismuth film electrode (BiFE) in an injection-moulded electrochemical micro-flow cell. The polystyrene three-electrode flow cell was fabricated with electrodes moulded from a conducting grade of polystyrene containing 40% carbon fibre, one of which was precoated with Ag to enable its use as an on-chip Ag/AgCl reference electrode. CAdSV of Co(II) and Ni(II) in the presence of dimethylglyoxime (DMG) with nitrite employed as the catalyst was performed in order to assess the performance of the flow cell with an in-line plated BiFE. The injection-moulded electrodes were found to be suitable substrates for the formation of BiFEs. Key parameters such as the plating solution matrix, plating flow rate, analysis flow rate, solution composition and square-wave parameters have been characterised and optimal conditions selected for successful and rapid analysis of Co(II) and Ni(II) at the ppb level. The analytical response was linear over the range 1 to 20 ppb and deoxygenation of the sample solution was not required. The successful coupling of a microfluidic flow cell with a BiFE, thereby forming a “mercury-free” AdSV flow analysis sensor, shows promise for industrial and in-the-field applications where inexpensive, compact, and robust instrumentation capable of low-volume analysis is required.

AB - Catalytic adsorptive stripping voltammetry (CAdSV) has been demonstrated at a bismuth film electrode (BiFE) in an injection-moulded electrochemical micro-flow cell. The polystyrene three-electrode flow cell was fabricated with electrodes moulded from a conducting grade of polystyrene containing 40% carbon fibre, one of which was precoated with Ag to enable its use as an on-chip Ag/AgCl reference electrode. CAdSV of Co(II) and Ni(II) in the presence of dimethylglyoxime (DMG) with nitrite employed as the catalyst was performed in order to assess the performance of the flow cell with an in-line plated BiFE. The injection-moulded electrodes were found to be suitable substrates for the formation of BiFEs. Key parameters such as the plating solution matrix, plating flow rate, analysis flow rate, solution composition and square-wave parameters have been characterised and optimal conditions selected for successful and rapid analysis of Co(II) and Ni(II) at the ppb level. The analytical response was linear over the range 1 to 20 ppb and deoxygenation of the sample solution was not required. The successful coupling of a microfluidic flow cell with a BiFE, thereby forming a “mercury-free” AdSV flow analysis sensor, shows promise for industrial and in-the-field applications where inexpensive, compact, and robust instrumentation capable of low-volume analysis is required.

KW - Bismuth film electrode (BiFE)

KW - Square-wave adsorptive stripping voltammetry

KW - Cobalt

KW - Nickel

KW - Dimethylglyoxime

KW - Electrochemical detection

KW - Flow cell

KW - Channel

KW - Injection moulding

KW - Sensor

U2 - 10.1007/s00216-008-1948-5

DO - 10.1007/s00216-008-1948-5

M3 - Journal article

VL - 391

SP - 1283

EP - 1292

JO - Analytical and Bioanalytical Chemistry

JF - Analytical and Bioanalytical Chemistry

SN - 1618-2642

IS - 4

ER -