Home > Research > Publications & Outputs > Effect of Coronal Fracture Angle on the Stabili...

Electronic data

  • _Draft Proof JOEIM-21-0339.R2

    Rights statement: The final, definitive version of this article has been published in the Journal, Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 236, 6, 2022, © SAGE Publications Ltd, 2022 by SAGE Publications Ltd at the Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine page: https://journals.sagepub.com/home/SPP on SAGE Journals Online: http://journals.sagepub.com/

    Accepted author manuscript, 5.47 MB, PDF document

    Available under license: CC BY-NC: Creative Commons Attribution-NonCommercial 4.0 International License

Links

Text available via DOI:

View graph of relations

Effect of Coronal Fracture Angle on the Stability of Screw Fixation in Medial Malleolar Fractures: A Finite Element Analysis

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Published

Standard

Effect of Coronal Fracture Angle on the Stability of Screw Fixation in Medial Malleolar Fractures: A Finite Element Analysis. / Emre, Tuluhan Yunus; Celik, H Kursat; Arik, Hasan O et al.
In: Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, Vol. 236, No. 6, 01.06.2022, p. 825-840.

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Harvard

Emre, TY, Celik, HK, Arik, HO, Rennie, A & Kose, O 2022, 'Effect of Coronal Fracture Angle on the Stability of Screw Fixation in Medial Malleolar Fractures: A Finite Element Analysis', Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, vol. 236, no. 6, pp. 825-840. https://doi.org/10.1177/09544119221089723

APA

Emre, T. Y., Celik, H. K., Arik, H. O., Rennie, A., & Kose, O. (2022). Effect of Coronal Fracture Angle on the Stability of Screw Fixation in Medial Malleolar Fractures: A Finite Element Analysis. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 236(6), 825-840. https://doi.org/10.1177/09544119221089723

Vancouver

Emre TY, Celik HK, Arik HO, Rennie A, Kose O. Effect of Coronal Fracture Angle on the Stability of Screw Fixation in Medial Malleolar Fractures: A Finite Element Analysis. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 2022 Jun 1;236(6):825-840. Epub 2022 Apr 21. doi: 10.1177/09544119221089723

Author

Emre, Tuluhan Yunus ; Celik, H Kursat ; Arik, Hasan O et al. / Effect of Coronal Fracture Angle on the Stability of Screw Fixation in Medial Malleolar Fractures : A Finite Element Analysis. In: Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 2022 ; Vol. 236, No. 6. pp. 825-840.

Bibtex

@article{34094c146cd7410b9a3b844417989c89,
title = "Effect of Coronal Fracture Angle on the Stability of Screw Fixation in Medial Malleolar Fractures: A Finite Element Analysis",
abstract = "Malleolar screw fixation is the most widely used treatment method for medial malleolar (MM) fractures. Here, although buttress plate fixation is advocated for vertical MM fractures, the angular discrimination between oblique and vertical MM fractures is still not fully understood. The purpose of this study is to test the adequacy of screw fixation in MM fractures with different angles and determination of a {\textquoteleft}critical fracture angle{\textquoteright} to guide surgeons in the decision-making for screw fixation for MM fractures by utilizing an advanced engineering simulation approach. In addition to loading of the healthy tibia structure, various cases of the MM fracture double screw fixation (14 simulation scenarios in total with fracture angles between 30° and 90°, in 5° increments) were considered in this research and their static loading conditions just after fixation operation were simulated through nonlinear (geometric and contact nonlinearity) finite element analysis (FEA). Patient-specific computed tomography scan data, parametric three-dimensional solid modelling and finite element method (FEM) based engineering codes were employed in order to simulate the fixation scenarios. Visual and numerical outputs for the deformation and stress distributions, separation and sliding behaviours of the MM fracture fragments of various screw fixations were clearly exhibited through FEA results. Minimum and maximum separation distances (gap) of 3.75 and 150.34 µm between fracture fragments at fracture angles of 30° and 90° were calculated respectively against minimum and maximum sliding distances of 25.87 and 41.37 µm between fracture fragments at fracture angles of 90° and 35°, respectively. The FEA results revealed that while the separation distance was increasing, the sliding distance was decreasing and there were no distinct differences in sliding distances in the scenarios from fracture angles of 30°–90°. The limitations and errors in a FEA study are inevitable, however, it was interpreted that the FEA scenarios were setup in this study by utilizing acceptable assumptions providing logical outputs under pre-defined boundary conditions. Finally, the fracture healing threshold for separation and/or sliding distance between fracture fragments was assigned as 100 µm by referring to previous literature and it was concluded that the screws fixed perpendicular to the fracture in a MM fracture with more than 70° angle with the tibial plafond results in a significant articular separation (>100 µm) during single-leg stand. Below this critical angle of 70°, two screws provide sufficient fixation.",
keywords = "Medial Malleolus Fracture, Fracture Angle, Fixation, Finite Element Analysis, Biomechanics",
author = "Emre, {Tuluhan Yunus} and Celik, {H Kursat} and Arik, {Hasan O} and Allan Rennie and Ozkan Kose",
note = "The final, definitive version of this article has been published in the Journal, Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 236, 6, 2022, {\textcopyright} SAGE Publications Ltd, 2022 by SAGE Publications Ltd at the Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine page: https://journals.sagepub.com/home/SPP on SAGE Journals Online: http://journals.sagepub.com/ ",
year = "2022",
month = jun,
day = "1",
doi = "10.1177/09544119221089723",
language = "English",
volume = "236",
pages = "825--840",
journal = "Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine",
issn = "0954-4119",
publisher = "SAGE Publications Ltd",
number = "6",

}

RIS

TY - JOUR

T1 - Effect of Coronal Fracture Angle on the Stability of Screw Fixation in Medial Malleolar Fractures

T2 - A Finite Element Analysis

AU - Emre, Tuluhan Yunus

AU - Celik, H Kursat

AU - Arik, Hasan O

AU - Rennie, Allan

AU - Kose, Ozkan

N1 - The final, definitive version of this article has been published in the Journal, Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 236, 6, 2022, © SAGE Publications Ltd, 2022 by SAGE Publications Ltd at the Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine page: https://journals.sagepub.com/home/SPP on SAGE Journals Online: http://journals.sagepub.com/

PY - 2022/6/1

Y1 - 2022/6/1

N2 - Malleolar screw fixation is the most widely used treatment method for medial malleolar (MM) fractures. Here, although buttress plate fixation is advocated for vertical MM fractures, the angular discrimination between oblique and vertical MM fractures is still not fully understood. The purpose of this study is to test the adequacy of screw fixation in MM fractures with different angles and determination of a ‘critical fracture angle’ to guide surgeons in the decision-making for screw fixation for MM fractures by utilizing an advanced engineering simulation approach. In addition to loading of the healthy tibia structure, various cases of the MM fracture double screw fixation (14 simulation scenarios in total with fracture angles between 30° and 90°, in 5° increments) were considered in this research and their static loading conditions just after fixation operation were simulated through nonlinear (geometric and contact nonlinearity) finite element analysis (FEA). Patient-specific computed tomography scan data, parametric three-dimensional solid modelling and finite element method (FEM) based engineering codes were employed in order to simulate the fixation scenarios. Visual and numerical outputs for the deformation and stress distributions, separation and sliding behaviours of the MM fracture fragments of various screw fixations were clearly exhibited through FEA results. Minimum and maximum separation distances (gap) of 3.75 and 150.34 µm between fracture fragments at fracture angles of 30° and 90° were calculated respectively against minimum and maximum sliding distances of 25.87 and 41.37 µm between fracture fragments at fracture angles of 90° and 35°, respectively. The FEA results revealed that while the separation distance was increasing, the sliding distance was decreasing and there were no distinct differences in sliding distances in the scenarios from fracture angles of 30°–90°. The limitations and errors in a FEA study are inevitable, however, it was interpreted that the FEA scenarios were setup in this study by utilizing acceptable assumptions providing logical outputs under pre-defined boundary conditions. Finally, the fracture healing threshold for separation and/or sliding distance between fracture fragments was assigned as 100 µm by referring to previous literature and it was concluded that the screws fixed perpendicular to the fracture in a MM fracture with more than 70° angle with the tibial plafond results in a significant articular separation (>100 µm) during single-leg stand. Below this critical angle of 70°, two screws provide sufficient fixation.

AB - Malleolar screw fixation is the most widely used treatment method for medial malleolar (MM) fractures. Here, although buttress plate fixation is advocated for vertical MM fractures, the angular discrimination between oblique and vertical MM fractures is still not fully understood. The purpose of this study is to test the adequacy of screw fixation in MM fractures with different angles and determination of a ‘critical fracture angle’ to guide surgeons in the decision-making for screw fixation for MM fractures by utilizing an advanced engineering simulation approach. In addition to loading of the healthy tibia structure, various cases of the MM fracture double screw fixation (14 simulation scenarios in total with fracture angles between 30° and 90°, in 5° increments) were considered in this research and their static loading conditions just after fixation operation were simulated through nonlinear (geometric and contact nonlinearity) finite element analysis (FEA). Patient-specific computed tomography scan data, parametric three-dimensional solid modelling and finite element method (FEM) based engineering codes were employed in order to simulate the fixation scenarios. Visual and numerical outputs for the deformation and stress distributions, separation and sliding behaviours of the MM fracture fragments of various screw fixations were clearly exhibited through FEA results. Minimum and maximum separation distances (gap) of 3.75 and 150.34 µm between fracture fragments at fracture angles of 30° and 90° were calculated respectively against minimum and maximum sliding distances of 25.87 and 41.37 µm between fracture fragments at fracture angles of 90° and 35°, respectively. The FEA results revealed that while the separation distance was increasing, the sliding distance was decreasing and there were no distinct differences in sliding distances in the scenarios from fracture angles of 30°–90°. The limitations and errors in a FEA study are inevitable, however, it was interpreted that the FEA scenarios were setup in this study by utilizing acceptable assumptions providing logical outputs under pre-defined boundary conditions. Finally, the fracture healing threshold for separation and/or sliding distance between fracture fragments was assigned as 100 µm by referring to previous literature and it was concluded that the screws fixed perpendicular to the fracture in a MM fracture with more than 70° angle with the tibial plafond results in a significant articular separation (>100 µm) during single-leg stand. Below this critical angle of 70°, two screws provide sufficient fixation.

KW - Medial Malleolus Fracture

KW - Fracture Angle

KW - Fixation

KW - Finite Element Analysis

KW - Biomechanics

U2 - 10.1177/09544119221089723

DO - 10.1177/09544119221089723

M3 - Journal article

VL - 236

SP - 825

EP - 840

JO - Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine

JF - Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine

SN - 0954-4119

IS - 6

ER -