Home > Research > Publications & Outputs > Field evaluation of a passive personal air samp...

Links

Text available via DOI:

View graph of relations

Field evaluation of a passive personal air sampler for screening of PAH exposure in workplaces

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Published

Standard

Field evaluation of a passive personal air sampler for screening of PAH exposure in workplaces. / Bohlin, Pernilla; Jones, Kevin C.; Levin, Jan Olof et al.
In: Journal of Environmental Monitoring, Vol. 12, No. 7, 01.07.2010, p. 1437-1444.

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Harvard

Bohlin, P, Jones, KC, Levin, JO, Lindahl, R & Strandberg, B 2010, 'Field evaluation of a passive personal air sampler for screening of PAH exposure in workplaces', Journal of Environmental Monitoring, vol. 12, no. 7, pp. 1437-1444. https://doi.org/10.1039/c0em00018c

APA

Bohlin, P., Jones, K. C., Levin, J. O., Lindahl, R., & Strandberg, B. (2010). Field evaluation of a passive personal air sampler for screening of PAH exposure in workplaces. Journal of Environmental Monitoring, 12(7), 1437-1444. https://doi.org/10.1039/c0em00018c

Vancouver

Bohlin P, Jones KC, Levin JO, Lindahl R, Strandberg B. Field evaluation of a passive personal air sampler for screening of PAH exposure in workplaces. Journal of Environmental Monitoring. 2010 Jul 1;12(7):1437-1444. Epub 2010 May 11. doi: 10.1039/c0em00018c

Author

Bohlin, Pernilla ; Jones, Kevin C. ; Levin, Jan Olof et al. / Field evaluation of a passive personal air sampler for screening of PAH exposure in workplaces. In: Journal of Environmental Monitoring. 2010 ; Vol. 12, No. 7. pp. 1437-1444.

Bibtex

@article{a094f58b1a52424f908f66de84e80f7a,
title = "Field evaluation of a passive personal air sampler for screening of PAH exposure in workplaces",
abstract = "New sampling methods are needed to simplify and enable frequent monitoring of workers' exposure to polycyclic aromatic hydrocarbons (PAHs). The sampler needs to fulfil some key operational requirements for occupational exposure assessments: (i) be useable as a personal sampler; (ii) work over 8 h exposure time; (iii) sequester PAHs both in gas and particle phase, (iv) yield reliable estimates of air concentrations. Here, a new smaller design of the traditional polyurethane foam (PUF) passive air sampler (PAS) (i.e. a 'mini-PUF') was introduced and assessed against these requirements in sites with elevated PAH concentrations. The exposure times were 2 weeks and 8 hours. The obtained sampling rates (R-values) were not significantly different between gas phase (0.4-3.3 m3 day-1, 0.3-2.3 L min-1) and particle associated PAHs (0.5-1.9 m3 day-1, 0.4-1.3 L min-1). The accuracy in estimating air concentrations was within ±25% from the active sampler for half of the PAHs for the mini-PUF under 8 h exposures. Significant correlations (p < 0.003) were found between personally deployed mini-PUFs and a co-deployed personal active sampling method. This together with the low costs and ease-of-use of the mini-PUF encourage application in exposure assessments.",
author = "Pernilla Bohlin and Jones, {Kevin C.} and Levin, {Jan Olof} and Roger Lindahl and Bo Strandberg",
year = "2010",
month = jul,
day = "1",
doi = "10.1039/c0em00018c",
language = "English",
volume = "12",
pages = "1437--1444",
journal = "Journal of Environmental Monitoring",
issn = "1464-0325",
publisher = "Royal Society of Chemistry",
number = "7",

}

RIS

TY - JOUR

T1 - Field evaluation of a passive personal air sampler for screening of PAH exposure in workplaces

AU - Bohlin, Pernilla

AU - Jones, Kevin C.

AU - Levin, Jan Olof

AU - Lindahl, Roger

AU - Strandberg, Bo

PY - 2010/7/1

Y1 - 2010/7/1

N2 - New sampling methods are needed to simplify and enable frequent monitoring of workers' exposure to polycyclic aromatic hydrocarbons (PAHs). The sampler needs to fulfil some key operational requirements for occupational exposure assessments: (i) be useable as a personal sampler; (ii) work over 8 h exposure time; (iii) sequester PAHs both in gas and particle phase, (iv) yield reliable estimates of air concentrations. Here, a new smaller design of the traditional polyurethane foam (PUF) passive air sampler (PAS) (i.e. a 'mini-PUF') was introduced and assessed against these requirements in sites with elevated PAH concentrations. The exposure times were 2 weeks and 8 hours. The obtained sampling rates (R-values) were not significantly different between gas phase (0.4-3.3 m3 day-1, 0.3-2.3 L min-1) and particle associated PAHs (0.5-1.9 m3 day-1, 0.4-1.3 L min-1). The accuracy in estimating air concentrations was within ±25% from the active sampler for half of the PAHs for the mini-PUF under 8 h exposures. Significant correlations (p < 0.003) were found between personally deployed mini-PUFs and a co-deployed personal active sampling method. This together with the low costs and ease-of-use of the mini-PUF encourage application in exposure assessments.

AB - New sampling methods are needed to simplify and enable frequent monitoring of workers' exposure to polycyclic aromatic hydrocarbons (PAHs). The sampler needs to fulfil some key operational requirements for occupational exposure assessments: (i) be useable as a personal sampler; (ii) work over 8 h exposure time; (iii) sequester PAHs both in gas and particle phase, (iv) yield reliable estimates of air concentrations. Here, a new smaller design of the traditional polyurethane foam (PUF) passive air sampler (PAS) (i.e. a 'mini-PUF') was introduced and assessed against these requirements in sites with elevated PAH concentrations. The exposure times were 2 weeks and 8 hours. The obtained sampling rates (R-values) were not significantly different between gas phase (0.4-3.3 m3 day-1, 0.3-2.3 L min-1) and particle associated PAHs (0.5-1.9 m3 day-1, 0.4-1.3 L min-1). The accuracy in estimating air concentrations was within ±25% from the active sampler for half of the PAHs for the mini-PUF under 8 h exposures. Significant correlations (p < 0.003) were found between personally deployed mini-PUFs and a co-deployed personal active sampling method. This together with the low costs and ease-of-use of the mini-PUF encourage application in exposure assessments.

U2 - 10.1039/c0em00018c

DO - 10.1039/c0em00018c

M3 - Journal article

C2 - 20461262

AN - SCOPUS:77954641031

VL - 12

SP - 1437

EP - 1444

JO - Journal of Environmental Monitoring

JF - Journal of Environmental Monitoring

SN - 1464-0325

IS - 7

ER -