Home > Research > Publications & Outputs > Heliox for inducible laryngeal obstruction (voc...

Links

Text available via DOI:

View graph of relations

Heliox for inducible laryngeal obstruction (vocal cord dysfunction): A systematic literature review

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Published

Standard

Heliox for inducible laryngeal obstruction (vocal cord dysfunction): A systematic literature review. / Slinger, Claire; Slinger, Richard; Vyas, Aashish et al.
In: Laryngoscope Investigative Otolarygnology, Vol. 4, No. 2, 30.04.2019, p. 255-258.

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Harvard

Slinger, C, Slinger, R, Vyas, A, Haines, J & Fowler, SJ 2019, 'Heliox for inducible laryngeal obstruction (vocal cord dysfunction): A systematic literature review', Laryngoscope Investigative Otolarygnology, vol. 4, no. 2, pp. 255-258. https://doi.org/10.1002/lio2.229

APA

Slinger, C., Slinger, R., Vyas, A., Haines, J., & Fowler, S. J. (2019). Heliox for inducible laryngeal obstruction (vocal cord dysfunction): A systematic literature review. Laryngoscope Investigative Otolarygnology, 4(2), 255-258. https://doi.org/10.1002/lio2.229

Vancouver

Slinger C, Slinger R, Vyas A, Haines J, Fowler SJ. Heliox for inducible laryngeal obstruction (vocal cord dysfunction): A systematic literature review. Laryngoscope Investigative Otolarygnology. 2019 Apr 30;4(2):255-258. Epub 2019 Feb 8. doi: 10.1002/lio2.229

Author

Slinger, Claire ; Slinger, Richard ; Vyas, Aashish et al. / Heliox for inducible laryngeal obstruction (vocal cord dysfunction) : A systematic literature review. In: Laryngoscope Investigative Otolarygnology. 2019 ; Vol. 4, No. 2. pp. 255-258.

Bibtex

@article{2d38a3c5915c48ada5c6e261f9d43190,
title = "Heliox for inducible laryngeal obstruction (vocal cord dysfunction): A systematic literature review",
abstract = "Objectives: To perform a systematic literature review on the use of Heliox with patients with inducible laryngeal obstruction/vocal cord dysfunction to: i) identify current evidence base; and ii) establish the methodological quality of published research. Methods: Articles published up to March 2018 were searched for key words and terms using Cochrane Library, MEDLINE, PubMed, CINAHL, EMBASE and Dynamed. Studies were included if they presented original research into the use of Heliox for vocal cord dysfunction. Results: Only three studies met the inclusion criteria for review. All reported favorable results for the use of Heliox as an adjunctive therapy for vocal cord dysfunction but none had sufficient methodological quality to support their conclusions. Conclusion: Despite review articles recommending the use of Heliox in vocal cord dysfunction, there is a lack of good quality research to support this conclusion. There is a need for further research to investigate the effectiveness of Heliox as an adjunctive therapy for vocal cord dysfunction. Level of Evidence: 4",
keywords = "Heliox, inducible laryngeal obstruction, iLO, VCD, vocal cord dysfunction",
author = "Claire Slinger and Richard Slinger and Aashish Vyas and Jemma Haines and Fowler, {Stephen J.}",
year = "2019",
month = apr,
day = "30",
doi = "10.1002/lio2.229",
language = "English",
volume = "4",
pages = "255--258",
journal = "Laryngoscope Investigative Otolarygnology",
number = "2",

}

RIS

TY - JOUR

T1 - Heliox for inducible laryngeal obstruction (vocal cord dysfunction)

T2 - A systematic literature review

AU - Slinger, Claire

AU - Slinger, Richard

AU - Vyas, Aashish

AU - Haines, Jemma

AU - Fowler, Stephen J.

PY - 2019/4/30

Y1 - 2019/4/30

N2 - Objectives: To perform a systematic literature review on the use of Heliox with patients with inducible laryngeal obstruction/vocal cord dysfunction to: i) identify current evidence base; and ii) establish the methodological quality of published research. Methods: Articles published up to March 2018 were searched for key words and terms using Cochrane Library, MEDLINE, PubMed, CINAHL, EMBASE and Dynamed. Studies were included if they presented original research into the use of Heliox for vocal cord dysfunction. Results: Only three studies met the inclusion criteria for review. All reported favorable results for the use of Heliox as an adjunctive therapy for vocal cord dysfunction but none had sufficient methodological quality to support their conclusions. Conclusion: Despite review articles recommending the use of Heliox in vocal cord dysfunction, there is a lack of good quality research to support this conclusion. There is a need for further research to investigate the effectiveness of Heliox as an adjunctive therapy for vocal cord dysfunction. Level of Evidence: 4

AB - Objectives: To perform a systematic literature review on the use of Heliox with patients with inducible laryngeal obstruction/vocal cord dysfunction to: i) identify current evidence base; and ii) establish the methodological quality of published research. Methods: Articles published up to March 2018 were searched for key words and terms using Cochrane Library, MEDLINE, PubMed, CINAHL, EMBASE and Dynamed. Studies were included if they presented original research into the use of Heliox for vocal cord dysfunction. Results: Only three studies met the inclusion criteria for review. All reported favorable results for the use of Heliox as an adjunctive therapy for vocal cord dysfunction but none had sufficient methodological quality to support their conclusions. Conclusion: Despite review articles recommending the use of Heliox in vocal cord dysfunction, there is a lack of good quality research to support this conclusion. There is a need for further research to investigate the effectiveness of Heliox as an adjunctive therapy for vocal cord dysfunction. Level of Evidence: 4

KW - Heliox

KW - inducible laryngeal obstruction

KW - iLO

KW - VCD

KW - vocal cord dysfunction

U2 - 10.1002/lio2.229

DO - 10.1002/lio2.229

M3 - Journal article

VL - 4

SP - 255

EP - 258

JO - Laryngoscope Investigative Otolarygnology

JF - Laryngoscope Investigative Otolarygnology

IS - 2