Research output: Contribution to conference - Without ISBN/ISSN › Conference paper › peer-review
Research output: Contribution to conference - Without ISBN/ISSN › Conference paper › peer-review
}
TY - CONF
T1 - Linear EMT for the detection of faults in metallic planar structures (DIF).
AU - Yin, W.
AU - Ma, X.
AU - Zysko, G.
AU - Peyton, A. J.
PY - 2007/9
Y1 - 2007/9
N2 - This paper describes a linear planar electromagnetic induction tomography (EMT) system for the detection of conductivity in-homogeneity inside a metallic planar structure. Sensor coils are distributed to form a linear array with their axis parallel but perpendicular to the plate under inspection. The forward solution for the sensor array next to a homogenous conductive planar structure is based on the analytical solution provided by Deeds and Dodd. Numerical results of the forward solution are provided by FEM simulations for several cases of inhomogeneous conductivity distributions. The sensitivity matrix for a prototype sensor was computed by numerical evaluation of the analytical solution. For the inverse solution, a modified Newton-Raphson method was used to adjust the conductivity distribution to fit a set of inductances measured from the sensor array in a least-squared sense. Good estimates for the locations of low conductivity faults were obtained. The differences in mutual inductance of the coil pairs when placed next to a homogenous reference conductor and next to a conductor with faults were used as the input of the inverse solution. Inverse results based on FEM simulated data verified this method.
AB - This paper describes a linear planar electromagnetic induction tomography (EMT) system for the detection of conductivity in-homogeneity inside a metallic planar structure. Sensor coils are distributed to form a linear array with their axis parallel but perpendicular to the plate under inspection. The forward solution for the sensor array next to a homogenous conductive planar structure is based on the analytical solution provided by Deeds and Dodd. Numerical results of the forward solution are provided by FEM simulations for several cases of inhomogeneous conductivity distributions. The sensitivity matrix for a prototype sensor was computed by numerical evaluation of the analytical solution. For the inverse solution, a modified Newton-Raphson method was used to adjust the conductivity distribution to fit a set of inductances measured from the sensor array in a least-squared sense. Good estimates for the locations of low conductivity faults were obtained. The differences in mutual inductance of the coil pairs when placed next to a homogenous reference conductor and next to a conductor with faults were used as the input of the inverse solution. Inverse results based on FEM simulated data verified this method.
KW - Planar array
KW - electromagnetic
KW - induction
KW - tomography
KW - faults
KW - non-destructive testing
M3 - Conference paper
T2 - 5th World Congress on Industrial Process Tomography
Y2 - 3 September 2007 through 6 September 2007
ER -