Home > Research > Publications & Outputs > Macroscopic indicators of fault diagnosis and a...

Links

Text available via DOI:

View graph of relations

Macroscopic indicators of fault diagnosis and ageing in electrochemical double layer capacitors

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Published

Standard

Macroscopic indicators of fault diagnosis and ageing in electrochemical double layer capacitors. / Torregrossa, Dimitri; Toghill, Kathryn E.; Amstutz, Véronique et al.
In: Journal of Energy Storage, Vol. 2, 08.2015, p. 8-24.

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Harvard

Torregrossa, D, Toghill, KE, Amstutz, V, Girault, HH & Paolone, M 2015, 'Macroscopic indicators of fault diagnosis and ageing in electrochemical double layer capacitors', Journal of Energy Storage, vol. 2, pp. 8-24. https://doi.org/10.1016/j.est.2015.05.001

APA

Torregrossa, D., Toghill, K. E., Amstutz, V., Girault, H. H., & Paolone, M. (2015). Macroscopic indicators of fault diagnosis and ageing in electrochemical double layer capacitors. Journal of Energy Storage, 2, 8-24. https://doi.org/10.1016/j.est.2015.05.001

Vancouver

Torregrossa D, Toghill KE, Amstutz V, Girault HH, Paolone M. Macroscopic indicators of fault diagnosis and ageing in electrochemical double layer capacitors. Journal of Energy Storage. 2015 Aug;2:8-24. Epub 2015 Jun 1. doi: 10.1016/j.est.2015.05.001

Author

Torregrossa, Dimitri ; Toghill, Kathryn E. ; Amstutz, Véronique et al. / Macroscopic indicators of fault diagnosis and ageing in electrochemical double layer capacitors. In: Journal of Energy Storage. 2015 ; Vol. 2. pp. 8-24.

Bibtex

@article{d0b92aa38e2142e1bf1389cb46e88327,
title = "Macroscopic indicators of fault diagnosis and ageing in electrochemical double layer capacitors",
abstract = "The ageing behaviour of electric double layer (EDLC) supercapacitors during over-temperature and over-voltage stresses is described. Specific experimental tests were carried out in order to reproduce, under laboratory controlled conditions, the above-mentioned stresses. The obtained results are discussed and interpreted to define indicators that distinguish between over-temperature and over-voltage faults occurring in these devices. For each stress type post-mortem examinations of the EDLCs were performed to observe any specific physical damage. These examinations have been used to define the fundamental assumptions of the proposed fault indicators. Three fault indicators were identified and related to the evolution of the following SC parameters: (i) the equivalent series resistance, (ii) capacitance and (iii) decay voltage during the relaxation phase. Additionally, new accelerated ageing and recovering phases were detected during combined high-pulsed power cycling and life endurance stresses.",
keywords = "Accelerated ageing phase, Fault diagnosis, Recovering phase, Supercapacitors",
author = "Dimitri Torregrossa and Toghill, {Kathryn E.} and V{\'e}ronique Amstutz and Girault, {Hubert H.} and Mario Paolone",
year = "2015",
month = aug,
doi = "10.1016/j.est.2015.05.001",
language = "English",
volume = "2",
pages = "8--24",
journal = "Journal of Energy Storage",
publisher = "Elsevier BV",

}

RIS

TY - JOUR

T1 - Macroscopic indicators of fault diagnosis and ageing in electrochemical double layer capacitors

AU - Torregrossa, Dimitri

AU - Toghill, Kathryn E.

AU - Amstutz, Véronique

AU - Girault, Hubert H.

AU - Paolone, Mario

PY - 2015/8

Y1 - 2015/8

N2 - The ageing behaviour of electric double layer (EDLC) supercapacitors during over-temperature and over-voltage stresses is described. Specific experimental tests were carried out in order to reproduce, under laboratory controlled conditions, the above-mentioned stresses. The obtained results are discussed and interpreted to define indicators that distinguish between over-temperature and over-voltage faults occurring in these devices. For each stress type post-mortem examinations of the EDLCs were performed to observe any specific physical damage. These examinations have been used to define the fundamental assumptions of the proposed fault indicators. Three fault indicators were identified and related to the evolution of the following SC parameters: (i) the equivalent series resistance, (ii) capacitance and (iii) decay voltage during the relaxation phase. Additionally, new accelerated ageing and recovering phases were detected during combined high-pulsed power cycling and life endurance stresses.

AB - The ageing behaviour of electric double layer (EDLC) supercapacitors during over-temperature and over-voltage stresses is described. Specific experimental tests were carried out in order to reproduce, under laboratory controlled conditions, the above-mentioned stresses. The obtained results are discussed and interpreted to define indicators that distinguish between over-temperature and over-voltage faults occurring in these devices. For each stress type post-mortem examinations of the EDLCs were performed to observe any specific physical damage. These examinations have been used to define the fundamental assumptions of the proposed fault indicators. Three fault indicators were identified and related to the evolution of the following SC parameters: (i) the equivalent series resistance, (ii) capacitance and (iii) decay voltage during the relaxation phase. Additionally, new accelerated ageing and recovering phases were detected during combined high-pulsed power cycling and life endurance stresses.

KW - Accelerated ageing phase

KW - Fault diagnosis

KW - Recovering phase

KW - Supercapacitors

U2 - 10.1016/j.est.2015.05.001

DO - 10.1016/j.est.2015.05.001

M3 - Journal article

AN - SCOPUS:84938094835

VL - 2

SP - 8

EP - 24

JO - Journal of Energy Storage

JF - Journal of Energy Storage

ER -