Home > Research > Publications & Outputs > Minimally invasive neutron beam monitoring for ...

Links

Text available via DOI:

View graph of relations

Minimally invasive neutron beam monitoring for single-event effects accelerated testing

Research output: Contribution in Book/Report/Proceedings - With ISBN/ISSNConference contribution/Paper

Published

Standard

Minimally invasive neutron beam monitoring for single-event effects accelerated testing. / Zhang, Lyn H.; Platt, S. P.
RADECS 2011 - 12th European Conference on Radiation and Its Effects on Component and Systems, Conference Proceedings. 2011. p. 945-949 6131336 (Proceedings of the European Conference on Radiation and its Effects on Components and Systems, RADECS).

Research output: Contribution in Book/Report/Proceedings - With ISBN/ISSNConference contribution/Paper

Harvard

Zhang, LH & Platt, SP 2011, Minimally invasive neutron beam monitoring for single-event effects accelerated testing. in RADECS 2011 - 12th European Conference on Radiation and Its Effects on Component and Systems, Conference Proceedings., 6131336, Proceedings of the European Conference on Radiation and its Effects on Components and Systems, RADECS, pp. 945-949, 12th European Conference on Radiation and Its Effects on Component and Systems, RADECS 2011, Sevilla, Spain, 19/09/11. https://doi.org/10.1109/RADECS.2011.6131336

APA

Zhang, L. H., & Platt, S. P. (2011). Minimally invasive neutron beam monitoring for single-event effects accelerated testing. In RADECS 2011 - 12th European Conference on Radiation and Its Effects on Component and Systems, Conference Proceedings (pp. 945-949). Article 6131336 (Proceedings of the European Conference on Radiation and its Effects on Components and Systems, RADECS). https://doi.org/10.1109/RADECS.2011.6131336

Vancouver

Zhang LH, Platt SP. Minimally invasive neutron beam monitoring for single-event effects accelerated testing. In RADECS 2011 - 12th European Conference on Radiation and Its Effects on Component and Systems, Conference Proceedings. 2011. p. 945-949. 6131336. (Proceedings of the European Conference on Radiation and its Effects on Components and Systems, RADECS). doi: 10.1109/RADECS.2011.6131336

Author

Zhang, Lyn H. ; Platt, S. P. / Minimally invasive neutron beam monitoring for single-event effects accelerated testing. RADECS 2011 - 12th European Conference on Radiation and Its Effects on Component and Systems, Conference Proceedings. 2011. pp. 945-949 (Proceedings of the European Conference on Radiation and its Effects on Components and Systems, RADECS).

Bibtex

@inproceedings{b050fd9998d94fa4a21f68ea137a16ba,
title = "Minimally invasive neutron beam monitoring for single-event effects accelerated testing",
abstract = "The use of silicon photodiodes for local beam monitoring during neutron SEE tests is demonstrated. Results from irradiations at the LANSCE ICE House are presented and analyzed. Local fluence measurements can be made without significant pile-up, even in pulsed beams. Beam degradation by scatterers such as upstream experiments can be quantified.",
keywords = "Neutron radiation effects, Particle beam measurements, Semiconductor device testing, Silicon radiation detectors",
author = "Zhang, {Lyn H.} and Platt, {S. P.}",
year = "2011",
month = dec,
day = "1",
doi = "10.1109/RADECS.2011.6131336",
language = "English",
isbn = "9781457705878",
series = "Proceedings of the European Conference on Radiation and its Effects on Components and Systems, RADECS",
pages = "945--949",
booktitle = "RADECS 2011 - 12th European Conference on Radiation and Its Effects on Component and Systems, Conference Proceedings",
note = "12th European Conference on Radiation and Its Effects on Component and Systems, RADECS 2011 ; Conference date: 19-09-2011 Through 23-09-2011",

}

RIS

TY - GEN

T1 - Minimally invasive neutron beam monitoring for single-event effects accelerated testing

AU - Zhang, Lyn H.

AU - Platt, S. P.

PY - 2011/12/1

Y1 - 2011/12/1

N2 - The use of silicon photodiodes for local beam monitoring during neutron SEE tests is demonstrated. Results from irradiations at the LANSCE ICE House are presented and analyzed. Local fluence measurements can be made without significant pile-up, even in pulsed beams. Beam degradation by scatterers such as upstream experiments can be quantified.

AB - The use of silicon photodiodes for local beam monitoring during neutron SEE tests is demonstrated. Results from irradiations at the LANSCE ICE House are presented and analyzed. Local fluence measurements can be made without significant pile-up, even in pulsed beams. Beam degradation by scatterers such as upstream experiments can be quantified.

KW - Neutron radiation effects

KW - Particle beam measurements

KW - Semiconductor device testing

KW - Silicon radiation detectors

U2 - 10.1109/RADECS.2011.6131336

DO - 10.1109/RADECS.2011.6131336

M3 - Conference contribution/Paper

AN - SCOPUS:84860128213

SN - 9781457705878

T3 - Proceedings of the European Conference on Radiation and its Effects on Components and Systems, RADECS

SP - 945

EP - 949

BT - RADECS 2011 - 12th European Conference on Radiation and Its Effects on Component and Systems, Conference Proceedings

T2 - 12th European Conference on Radiation and Its Effects on Component and Systems, RADECS 2011

Y2 - 19 September 2011 through 23 September 2011

ER -