Home > Research > Publications & Outputs > Modelling and Transient Simulation of District ...

Links

Text available via DOI:

View graph of relations

Modelling and Transient Simulation of District Heating Networks Based on a Control Theory Approach

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Published

Standard

Modelling and Transient Simulation of District Heating Networks Based on a Control Theory Approach. / Schojda, Dominik; Scheipers, Jan; Roes, Jürgen et al.
In: Energies, Vol. 18, No. 3, 658, 31.01.2025.

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Harvard

APA

Vancouver

Schojda D, Scheipers J, Roes J, Hoster H. Modelling and Transient Simulation of District Heating Networks Based on a Control Theory Approach. Energies. 2025 Jan 31;18(3):658. doi: 10.3390/en18030658

Author

Schojda, Dominik ; Scheipers, Jan ; Roes, Jürgen et al. / Modelling and Transient Simulation of District Heating Networks Based on a Control Theory Approach. In: Energies. 2025 ; Vol. 18, No. 3.

Bibtex

@article{6ce26d3cd8534b65b0d5e218db65c9f3,
title = "Modelling and Transient Simulation of District Heating Networks Based on a Control Theory Approach",
abstract = "Heating districts have become one of the key infrastructures to efficiently and sustainably supply heat to consumers. With the current climate change crisis, not only are heating districts of the essence but their efficient and optimized operation as well. To analyze and achieve such an optimization, transient simulations of heating districts are needed. These simulations are a means of upgrading older town networks to smarter energy grids as well as an effective tool for the planning and building of newer heating networks. Therefore, this work presents an easy simulation method for the transient simulation of heating districts based on a control theory approach. The simulation method can calculate multiple-loop networks as well as non-looped networks and correctly predict how a heating network can behave over time. Additionally, this approach allows for the inclusion of new renewable energy sources into existing heating networks and to simulate the resulting network behavior. The method was tested on five different testcases involving a single-loop network, a multiple-loop network, and a real-life non-looped network. In each case, the calculated massflows were validated with the software Epanet (Version 2.2), while the simulated temperatures were compared to the theoretical steady-state values as well as the theoretical times of arrival of each heating network. The simulation results present a good approximation in each testcase. Finally, the limitations of the method are discussed, and a recommendation for the usage of the approach is given.",
author = "Dominik Schojda and Jan Scheipers and J{\"u}rgen Roes and Harry Hoster",
year = "2025",
month = jan,
day = "31",
doi = "10.3390/en18030658",
language = "English",
volume = "18",
journal = "Energies",
issn = "1996-1073",
publisher = "Multidisciplinary Digital Publishing Institute (MDPI)",
number = "3",

}

RIS

TY - JOUR

T1 - Modelling and Transient Simulation of District Heating Networks Based on a Control Theory Approach

AU - Schojda, Dominik

AU - Scheipers, Jan

AU - Roes, Jürgen

AU - Hoster, Harry

PY - 2025/1/31

Y1 - 2025/1/31

N2 - Heating districts have become one of the key infrastructures to efficiently and sustainably supply heat to consumers. With the current climate change crisis, not only are heating districts of the essence but their efficient and optimized operation as well. To analyze and achieve such an optimization, transient simulations of heating districts are needed. These simulations are a means of upgrading older town networks to smarter energy grids as well as an effective tool for the planning and building of newer heating networks. Therefore, this work presents an easy simulation method for the transient simulation of heating districts based on a control theory approach. The simulation method can calculate multiple-loop networks as well as non-looped networks and correctly predict how a heating network can behave over time. Additionally, this approach allows for the inclusion of new renewable energy sources into existing heating networks and to simulate the resulting network behavior. The method was tested on five different testcases involving a single-loop network, a multiple-loop network, and a real-life non-looped network. In each case, the calculated massflows were validated with the software Epanet (Version 2.2), while the simulated temperatures were compared to the theoretical steady-state values as well as the theoretical times of arrival of each heating network. The simulation results present a good approximation in each testcase. Finally, the limitations of the method are discussed, and a recommendation for the usage of the approach is given.

AB - Heating districts have become one of the key infrastructures to efficiently and sustainably supply heat to consumers. With the current climate change crisis, not only are heating districts of the essence but their efficient and optimized operation as well. To analyze and achieve such an optimization, transient simulations of heating districts are needed. These simulations are a means of upgrading older town networks to smarter energy grids as well as an effective tool for the planning and building of newer heating networks. Therefore, this work presents an easy simulation method for the transient simulation of heating districts based on a control theory approach. The simulation method can calculate multiple-loop networks as well as non-looped networks and correctly predict how a heating network can behave over time. Additionally, this approach allows for the inclusion of new renewable energy sources into existing heating networks and to simulate the resulting network behavior. The method was tested on five different testcases involving a single-loop network, a multiple-loop network, and a real-life non-looped network. In each case, the calculated massflows were validated with the software Epanet (Version 2.2), while the simulated temperatures were compared to the theoretical steady-state values as well as the theoretical times of arrival of each heating network. The simulation results present a good approximation in each testcase. Finally, the limitations of the method are discussed, and a recommendation for the usage of the approach is given.

U2 - 10.3390/en18030658

DO - 10.3390/en18030658

M3 - Journal article

VL - 18

JO - Energies

JF - Energies

SN - 1996-1073

IS - 3

M1 - 658

ER -