Home > Research > Publications & Outputs > Real-time, digital pulse-shape discrimination i...

Links

Text available via DOI:

View graph of relations

Real-time, digital pulse-shape discrimination in non-hazardous fast liquid scintillation detectors: Prospects for safety and security

Research output: Contribution in Book/Report/Proceedings - With ISBN/ISSNConference contribution/Paperpeer-review

Published

Standard

Real-time, digital pulse-shape discrimination in non-hazardous fast liquid scintillation detectors: Prospects for safety and security. / Joyce, M.J.; Aspinall, M.D.; Cave, F.D. et al.
ANIMMA 2011 - Proceedings: 2nd International Conference on Advancements in Nuclear Instrumentation, Measurement Methods and their Applications. IEEE, 2011.

Research output: Contribution in Book/Report/Proceedings - With ISBN/ISSNConference contribution/Paperpeer-review

Harvard

Joyce, MJ, Aspinall, MD, Cave, FD & Lavietes, AD 2011, Real-time, digital pulse-shape discrimination in non-hazardous fast liquid scintillation detectors: Prospects for safety and security. in ANIMMA 2011 - Proceedings: 2nd International Conference on Advancements in Nuclear Instrumentation, Measurement Methods and their Applications. IEEE. https://doi.org/10.1109/ANIMMA.2011.6172939

APA

Joyce, M. J., Aspinall, M. D., Cave, F. D., & Lavietes, A. D. (2011). Real-time, digital pulse-shape discrimination in non-hazardous fast liquid scintillation detectors: Prospects for safety and security. In ANIMMA 2011 - Proceedings: 2nd International Conference on Advancements in Nuclear Instrumentation, Measurement Methods and their Applications IEEE. https://doi.org/10.1109/ANIMMA.2011.6172939

Vancouver

Joyce MJ, Aspinall MD, Cave FD, Lavietes AD. Real-time, digital pulse-shape discrimination in non-hazardous fast liquid scintillation detectors: Prospects for safety and security. In ANIMMA 2011 - Proceedings: 2nd International Conference on Advancements in Nuclear Instrumentation, Measurement Methods and their Applications. IEEE. 2011 doi: 10.1109/ANIMMA.2011.6172939

Author

Joyce, M.J. ; Aspinall, M.D. ; Cave, F.D. et al. / Real-time, digital pulse-shape discrimination in non-hazardous fast liquid scintillation detectors: Prospects for safety and security. ANIMMA 2011 - Proceedings: 2nd International Conference on Advancements in Nuclear Instrumentation, Measurement Methods and their Applications. IEEE, 2011.

Bibtex

@inproceedings{1d297ca042fa436aa084c6ea012c1c1b,
title = "Real-time, digital pulse-shape discrimination in non-hazardous fast liquid scintillation detectors: Prospects for safety and security",
abstract = "Pulse-shape discrimination (PSD) in fast, organic scintillation detectors is a long-established technique used to separate neutrons and γ rays in mixed radiation fields. In the analogue domain the method can achieve separation in real time, but all knowledge of the pulses themselves is lost thereby preventing the possibility of any post- or repeated analysis. Also, it is typically reliant on electronic systems that are largely obsolete and which require significant experience to set up. In the digital domain, PSD is often more flexible but significant post-processing has usually been necessary to obtain neutron/γ-ray separation. Moreover, the scintillation media on which the technique relies usually have a low flashpoint and are thus deemed hazardous. This complicates the ease with which they are used in industrial applications. In this paper, results obtained with a new portable digital pulse-shape discrimination instrument are described. This instrument provides real-time, digital neutron/γ separation whilst preserving the synchronization with the time-of-arrival for each event, and realizing throughputs of 3×10 6 events per second. Furthermore, this system has been tested with a scintillation medium that is non-flammable and not hazardous.",
keywords = "Neutrons, Instruments, Detectors, Graphical user interfaces, Security, Real time systems, Materials",
author = "M.J. Joyce and M.D. Aspinall and F.D. Cave and A.D. Lavietes",
year = "2011",
doi = "10.1109/ANIMMA.2011.6172939",
language = "English",
isbn = "9781457709258",
booktitle = "ANIMMA 2011 - Proceedings: 2nd International Conference on Advancements in Nuclear Instrumentation, Measurement Methods and their Applications",
publisher = "IEEE",

}

RIS

TY - GEN

T1 - Real-time, digital pulse-shape discrimination in non-hazardous fast liquid scintillation detectors: Prospects for safety and security

AU - Joyce, M.J.

AU - Aspinall, M.D.

AU - Cave, F.D.

AU - Lavietes, A.D.

PY - 2011

Y1 - 2011

N2 - Pulse-shape discrimination (PSD) in fast, organic scintillation detectors is a long-established technique used to separate neutrons and γ rays in mixed radiation fields. In the analogue domain the method can achieve separation in real time, but all knowledge of the pulses themselves is lost thereby preventing the possibility of any post- or repeated analysis. Also, it is typically reliant on electronic systems that are largely obsolete and which require significant experience to set up. In the digital domain, PSD is often more flexible but significant post-processing has usually been necessary to obtain neutron/γ-ray separation. Moreover, the scintillation media on which the technique relies usually have a low flashpoint and are thus deemed hazardous. This complicates the ease with which they are used in industrial applications. In this paper, results obtained with a new portable digital pulse-shape discrimination instrument are described. This instrument provides real-time, digital neutron/γ separation whilst preserving the synchronization with the time-of-arrival for each event, and realizing throughputs of 3×10 6 events per second. Furthermore, this system has been tested with a scintillation medium that is non-flammable and not hazardous.

AB - Pulse-shape discrimination (PSD) in fast, organic scintillation detectors is a long-established technique used to separate neutrons and γ rays in mixed radiation fields. In the analogue domain the method can achieve separation in real time, but all knowledge of the pulses themselves is lost thereby preventing the possibility of any post- or repeated analysis. Also, it is typically reliant on electronic systems that are largely obsolete and which require significant experience to set up. In the digital domain, PSD is often more flexible but significant post-processing has usually been necessary to obtain neutron/γ-ray separation. Moreover, the scintillation media on which the technique relies usually have a low flashpoint and are thus deemed hazardous. This complicates the ease with which they are used in industrial applications. In this paper, results obtained with a new portable digital pulse-shape discrimination instrument are described. This instrument provides real-time, digital neutron/γ separation whilst preserving the synchronization with the time-of-arrival for each event, and realizing throughputs of 3×10 6 events per second. Furthermore, this system has been tested with a scintillation medium that is non-flammable and not hazardous.

KW - Neutrons

KW - Instruments

KW - Detectors

KW - Graphical user interfaces

KW - Security

KW - Real time systems

KW - Materials

U2 - 10.1109/ANIMMA.2011.6172939

DO - 10.1109/ANIMMA.2011.6172939

M3 - Conference contribution/Paper

SN - 9781457709258

BT - ANIMMA 2011 - Proceedings: 2nd International Conference on Advancements in Nuclear Instrumentation, Measurement Methods and their Applications

PB - IEEE

ER -