Home > Research > Publications & Outputs > Simultaneous detection of trace cadmium(II) and...
View graph of relations

Simultaneous detection of trace cadmium(II) and lead(II) using an unmodified edge plane pyrolytic graphite electrode

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Published

Standard

Simultaneous detection of trace cadmium(II) and lead(II) using an unmodified edge plane pyrolytic graphite electrode. / Lu, Min; Toghill, Kathryn E.; Compton, Richard G.
In: Electroanalysis, Vol. 23, No. 5, 05.2011, p. 1089-1094.

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Harvard

APA

Vancouver

Lu M, Toghill KE, Compton RG. Simultaneous detection of trace cadmium(II) and lead(II) using an unmodified edge plane pyrolytic graphite electrode. Electroanalysis. 2011 May;23(5):1089-1094. doi: 10.1002/elan.201000721

Author

Lu, Min ; Toghill, Kathryn E. ; Compton, Richard G. / Simultaneous detection of trace cadmium(II) and lead(II) using an unmodified edge plane pyrolytic graphite electrode. In: Electroanalysis. 2011 ; Vol. 23, No. 5. pp. 1089-1094.

Bibtex

@article{1270fa2e257846f6ad750a64d4c16c95,
title = "Simultaneous detection of trace cadmium(II) and lead(II) using an unmodified edge plane pyrolytic graphite electrode",
abstract = "We report the sensitive simultaneous detection of cadmium(II) and lead(II) using an unmodified edge plane pyrolytic graphite (EPPG) electrode via linear sweep anodic stripping voltammetry (LSASV). Simultaneous additions of the heavy metals gave two well separated stripping peaks observed over two linear ranges, 20 to 200 mu g L-1 and 2 to 20 mu g L-1. These gave detection limits of 0.3 mu g L-1 and 0.2 mu g L-1 for cadmium(II) and lead(II), respectively. The use of unmodified EPPG electrodes shows comparable performance to bismuth and mercury modified electrodes, and offers a simple and effective alternative to modified systems.",
keywords = "Cadmium(II), Lead(II), Edge plane pyrolytic graphite (EPPG) electrode, Linear sweep anodic stripping voltammetry (LSASV), ANODIC-STRIPPING VOLTAMMETRY, DOPED DIAMOND ELECTRODE, CARBON-CONTAINING ELECTRODES, BISMUTH-FILM ELECTRODES, ELECTROANALYTICAL DETERMINATION, PASTE ELECTRODES, GLASSY-CARBON, METALS, PB, PRECONCENTRATION",
author = "Min Lu and Toghill, {Kathryn E.} and Compton, {Richard G.}",
year = "2011",
month = may,
doi = "10.1002/elan.201000721",
language = "English",
volume = "23",
pages = "1089--1094",
journal = "Electroanalysis",
issn = "1040-0397",
publisher = "Wiley-VCH Verlag",
number = "5",

}

RIS

TY - JOUR

T1 - Simultaneous detection of trace cadmium(II) and lead(II) using an unmodified edge plane pyrolytic graphite electrode

AU - Lu, Min

AU - Toghill, Kathryn E.

AU - Compton, Richard G.

PY - 2011/5

Y1 - 2011/5

N2 - We report the sensitive simultaneous detection of cadmium(II) and lead(II) using an unmodified edge plane pyrolytic graphite (EPPG) electrode via linear sweep anodic stripping voltammetry (LSASV). Simultaneous additions of the heavy metals gave two well separated stripping peaks observed over two linear ranges, 20 to 200 mu g L-1 and 2 to 20 mu g L-1. These gave detection limits of 0.3 mu g L-1 and 0.2 mu g L-1 for cadmium(II) and lead(II), respectively. The use of unmodified EPPG electrodes shows comparable performance to bismuth and mercury modified electrodes, and offers a simple and effective alternative to modified systems.

AB - We report the sensitive simultaneous detection of cadmium(II) and lead(II) using an unmodified edge plane pyrolytic graphite (EPPG) electrode via linear sweep anodic stripping voltammetry (LSASV). Simultaneous additions of the heavy metals gave two well separated stripping peaks observed over two linear ranges, 20 to 200 mu g L-1 and 2 to 20 mu g L-1. These gave detection limits of 0.3 mu g L-1 and 0.2 mu g L-1 for cadmium(II) and lead(II), respectively. The use of unmodified EPPG electrodes shows comparable performance to bismuth and mercury modified electrodes, and offers a simple and effective alternative to modified systems.

KW - Cadmium(II)

KW - Lead(II)

KW - Edge plane pyrolytic graphite (EPPG) electrode

KW - Linear sweep anodic stripping voltammetry (LSASV)

KW - ANODIC-STRIPPING VOLTAMMETRY

KW - DOPED DIAMOND ELECTRODE

KW - CARBON-CONTAINING ELECTRODES

KW - BISMUTH-FILM ELECTRODES

KW - ELECTROANALYTICAL DETERMINATION

KW - PASTE ELECTRODES

KW - GLASSY-CARBON

KW - METALS

KW - PB

KW - PRECONCENTRATION

U2 - 10.1002/elan.201000721

DO - 10.1002/elan.201000721

M3 - Journal article

VL - 23

SP - 1089

EP - 1094

JO - Electroanalysis

JF - Electroanalysis

SN - 1040-0397

IS - 5

ER -