Home > Research > Publications & Outputs > Thermal performance evaluation of school buildi...

Links

Text available via DOI:

View graph of relations

Thermal performance evaluation of school buildings using a children-based adaptive comfort model

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Published

Standard

Thermal performance evaluation of school buildings using a children-based adaptive comfort model. / Teli, Despoina; Bourikas, Leonidas; James, Patrick et al.
In: Procedia Environmental Sciences, Vol. 38, 11.04.2017, p. 844-851.

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Harvard

APA

Vancouver

Teli D, Bourikas L, James P, Bahaj A. Thermal performance evaluation of school buildings using a children-based adaptive comfort model. Procedia Environmental Sciences. 2017 Apr 11;38:844-851. doi: 10.1016/j.proenv.2017.03.170

Author

Teli, Despoina ; Bourikas, Leonidas ; James, Patrick et al. / Thermal performance evaluation of school buildings using a children-based adaptive comfort model. In: Procedia Environmental Sciences. 2017 ; Vol. 38. pp. 844-851.

Bibtex

@article{3a0a871abcb94050be88f962c84770a1,
title = "Thermal performance evaluation of school buildings using a children-based adaptive comfort model",
abstract = "This paper investigates the thermal performance of four school buildings of different ages and characteristics, using current EU overheating criteria and {\textquoteleft}adjusted{\textquoteright} criteria based on children{\textquoteright}s lower comfort temperature found in recent research. Data collected in Southampton, UK, between 2011-2015 are used in the analysis, which consists of two parts: a) the development of an adaptive comfort model associating children{\textquoteright}s comfort temperature to outdoor climate based on approximately 2,800 thermal comfort responses from children, and b) the thermal performance evaluation of four case study schools (built in 1894, 1929, 1978 and 2013) with the use of 5-minute air temperature measurements during spring/summer from a total of 43 classrooms. The two models, current (adult-based) and adapted to pupils, are applied to the methodology for overheating assessment based on the European standard EN 15251. Results show that there is no overheating in the schools when the classroom temperatures were assessed with the current adult-based model, while when using the children-based model overheating was identified in three out of the four schools. Interestingly, the school with the most acceptable summer performance is the oldest, an 1890s medium-weight building. The modern (2013) school had the most stable, yet high air temperatures amongst the studied schools. The study highlights the emerging issue of summer overheating in heating-dominated countries such as the UK, where this has not been traditionally a concern. The problem is exacerbated by a single-sided focus on reducing heating loads without taking appropriate measures for summer comfort, the global warming trends and children{\textquoteright}s sensitivity to high temperatures. This paper highlights the challenge of designing school buildings with acceptable year-round thermal and energy performance and the need to set higher standards in the school building design, using children-based criteria.",
keywords = "Overheating, School buildings, Adaptive comfort, Children's thermal comfort",
author = "Despoina Teli and Leonidas Bourikas and Patrick James and Abubakr Bahaj",
year = "2017",
month = apr,
day = "11",
doi = "10.1016/j.proenv.2017.03.170",
language = "English",
volume = "38",
pages = "844--851",
journal = "Procedia Environmental Sciences",
issn = "1878-0296",
publisher = "Elsevier",

}

RIS

TY - JOUR

T1 - Thermal performance evaluation of school buildings using a children-based adaptive comfort model

AU - Teli, Despoina

AU - Bourikas, Leonidas

AU - James, Patrick

AU - Bahaj, Abubakr

PY - 2017/4/11

Y1 - 2017/4/11

N2 - This paper investigates the thermal performance of four school buildings of different ages and characteristics, using current EU overheating criteria and ‘adjusted’ criteria based on children’s lower comfort temperature found in recent research. Data collected in Southampton, UK, between 2011-2015 are used in the analysis, which consists of two parts: a) the development of an adaptive comfort model associating children’s comfort temperature to outdoor climate based on approximately 2,800 thermal comfort responses from children, and b) the thermal performance evaluation of four case study schools (built in 1894, 1929, 1978 and 2013) with the use of 5-minute air temperature measurements during spring/summer from a total of 43 classrooms. The two models, current (adult-based) and adapted to pupils, are applied to the methodology for overheating assessment based on the European standard EN 15251. Results show that there is no overheating in the schools when the classroom temperatures were assessed with the current adult-based model, while when using the children-based model overheating was identified in three out of the four schools. Interestingly, the school with the most acceptable summer performance is the oldest, an 1890s medium-weight building. The modern (2013) school had the most stable, yet high air temperatures amongst the studied schools. The study highlights the emerging issue of summer overheating in heating-dominated countries such as the UK, where this has not been traditionally a concern. The problem is exacerbated by a single-sided focus on reducing heating loads without taking appropriate measures for summer comfort, the global warming trends and children’s sensitivity to high temperatures. This paper highlights the challenge of designing school buildings with acceptable year-round thermal and energy performance and the need to set higher standards in the school building design, using children-based criteria.

AB - This paper investigates the thermal performance of four school buildings of different ages and characteristics, using current EU overheating criteria and ‘adjusted’ criteria based on children’s lower comfort temperature found in recent research. Data collected in Southampton, UK, between 2011-2015 are used in the analysis, which consists of two parts: a) the development of an adaptive comfort model associating children’s comfort temperature to outdoor climate based on approximately 2,800 thermal comfort responses from children, and b) the thermal performance evaluation of four case study schools (built in 1894, 1929, 1978 and 2013) with the use of 5-minute air temperature measurements during spring/summer from a total of 43 classrooms. The two models, current (adult-based) and adapted to pupils, are applied to the methodology for overheating assessment based on the European standard EN 15251. Results show that there is no overheating in the schools when the classroom temperatures were assessed with the current adult-based model, while when using the children-based model overheating was identified in three out of the four schools. Interestingly, the school with the most acceptable summer performance is the oldest, an 1890s medium-weight building. The modern (2013) school had the most stable, yet high air temperatures amongst the studied schools. The study highlights the emerging issue of summer overheating in heating-dominated countries such as the UK, where this has not been traditionally a concern. The problem is exacerbated by a single-sided focus on reducing heating loads without taking appropriate measures for summer comfort, the global warming trends and children’s sensitivity to high temperatures. This paper highlights the challenge of designing school buildings with acceptable year-round thermal and energy performance and the need to set higher standards in the school building design, using children-based criteria.