Home > Research > Publications & Outputs > Time-of-Flight Spectroscopy of 252 Cf Spontaneo...

Electronic data

Links

Text available via DOI:

View graph of relations

Time-of-Flight Spectroscopy of 252 Cf Spontaneous Fission Neutrons: Influences of Detector Voltage, Pulse-Shape Discrimination and Shielding

Research output: Contribution in Book/Report/Proceedings - With ISBN/ISSNConference contribution/Paperpeer-review

Published

Standard

Time-of-Flight Spectroscopy of 252 Cf Spontaneous Fission Neutrons: Influences of Detector Voltage, Pulse-Shape Discrimination and Shielding. / Grievson, Alex; Taylor, C. James; Roberts, Neil J. et al.
2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC). IEEE, 2021. 19 (IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)).

Research output: Contribution in Book/Report/Proceedings - With ISBN/ISSNConference contribution/Paperpeer-review

Harvard

Grievson, A, Taylor, CJ, Roberts, NJ, Bunce, M & Joyce, M 2021, Time-of-Flight Spectroscopy of 252 Cf Spontaneous Fission Neutrons: Influences of Detector Voltage, Pulse-Shape Discrimination and Shielding. in 2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)., 19, IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), IEEE. https://doi.org/10.1109/NSS/MIC42677.2020.9507768

APA

Grievson, A., Taylor, C. J., Roberts, N. J., Bunce, M., & Joyce, M. (2021). Time-of-Flight Spectroscopy of 252 Cf Spontaneous Fission Neutrons: Influences of Detector Voltage, Pulse-Shape Discrimination and Shielding. In 2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) Article 19 (IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)). IEEE. https://doi.org/10.1109/NSS/MIC42677.2020.9507768

Vancouver

Grievson A, Taylor CJ, Roberts NJ, Bunce M, Joyce M. Time-of-Flight Spectroscopy of 252 Cf Spontaneous Fission Neutrons: Influences of Detector Voltage, Pulse-Shape Discrimination and Shielding. In 2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC). IEEE. 2021. 19. (IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)). Epub 2020 Oct 31. doi: 10.1109/NSS/MIC42677.2020.9507768

Author

Grievson, Alex ; Taylor, C. James ; Roberts, Neil J. et al. / Time-of-Flight Spectroscopy of 252 Cf Spontaneous Fission Neutrons : Influences of Detector Voltage, Pulse-Shape Discrimination and Shielding. 2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC). IEEE, 2021. (IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)).

Bibtex

@inproceedings{f19c5630c1d549da9c738e59c3f3e233,
title = "Time-of-Flight Spectroscopy of 252 Cf Spontaneous Fission Neutrons: Influences of Detector Voltage, Pulse-Shape Discrimination and Shielding",
abstract = "Experimental measurements to explore the effect of detector voltage, pulse-shape discrimination (PSD) threshold and detector shielding on time-of-flight measurements of the 252Cf neutron spectrum made with organic scintillation detectors are described. It is found that detector voltage has a major effect, whilst changing the PSD threshold and shielding the detectors to optimize sensitivity to the desired gamma-neutron correlation results in a small effect.",
author = "Alex Grievson and Taylor, {C. James} and Roberts, {Neil J.} and Mike Bunce and Malcolm Joyce",
year = "2021",
month = aug,
day = "12",
doi = "10.1109/NSS/MIC42677.2020.9507768",
language = "English",
isbn = "9781728176949",
series = "IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)",
publisher = "IEEE",
booktitle = "2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)",

}

RIS

TY - GEN

T1 - Time-of-Flight Spectroscopy of 252 Cf Spontaneous Fission Neutrons

T2 - Influences of Detector Voltage, Pulse-Shape Discrimination and Shielding

AU - Grievson, Alex

AU - Taylor, C. James

AU - Roberts, Neil J.

AU - Bunce, Mike

AU - Joyce, Malcolm

PY - 2021/8/12

Y1 - 2021/8/12

N2 - Experimental measurements to explore the effect of detector voltage, pulse-shape discrimination (PSD) threshold and detector shielding on time-of-flight measurements of the 252Cf neutron spectrum made with organic scintillation detectors are described. It is found that detector voltage has a major effect, whilst changing the PSD threshold and shielding the detectors to optimize sensitivity to the desired gamma-neutron correlation results in a small effect.

AB - Experimental measurements to explore the effect of detector voltage, pulse-shape discrimination (PSD) threshold and detector shielding on time-of-flight measurements of the 252Cf neutron spectrum made with organic scintillation detectors are described. It is found that detector voltage has a major effect, whilst changing the PSD threshold and shielding the detectors to optimize sensitivity to the desired gamma-neutron correlation results in a small effect.

U2 - 10.1109/NSS/MIC42677.2020.9507768

DO - 10.1109/NSS/MIC42677.2020.9507768

M3 - Conference contribution/Paper

SN - 9781728176949

T3 - IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)

BT - 2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)

PB - IEEE

ER -