Home > Research > Publications & Outputs > Validation of a guideline-based composite outco...

Electronic data

  • 1465 9921 8 26

    Rights statement: © 2007 Spencer et al; licensee BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

    Final published version, 380 KB, PDF document

    Available under license: CC BY

Links

Text available via DOI:

View graph of relations

Validation of a guideline-based composite outcome assessment tool for asthma control.

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Published

Standard

Validation of a guideline-based composite outcome assessment tool for asthma control. / Spencer, Sally; Mayer, Bhabita; Bendall, Late L et al.
In: Respiratory Research, Vol. 8, No. 1, 17376233, 21.03.2007, p. 26-37.

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Harvard

Spencer, S, Mayer, B, Bendall, LL & Bateman, ED 2007, 'Validation of a guideline-based composite outcome assessment tool for asthma control.', Respiratory Research, vol. 8, no. 1, 17376233, pp. 26-37. https://doi.org/10.1186/1465-9921-8-26

APA

Spencer, S., Mayer, B., Bendall, L. L., & Bateman, E. D. (2007). Validation of a guideline-based composite outcome assessment tool for asthma control. Respiratory Research, 8(1), 26-37. Article 17376233. https://doi.org/10.1186/1465-9921-8-26

Vancouver

Spencer S, Mayer B, Bendall LL, Bateman ED. Validation of a guideline-based composite outcome assessment tool for asthma control. Respiratory Research. 2007 Mar 21;8(1):26-37. 17376233. doi: 10.1186/1465-9921-8-26

Author

Spencer, Sally ; Mayer, Bhabita ; Bendall, Late L et al. / Validation of a guideline-based composite outcome assessment tool for asthma control. In: Respiratory Research. 2007 ; Vol. 8, No. 1. pp. 26-37.

Bibtex

@article{bd79c628ff2e4452bd9d6af4d769e7b6,
title = "Validation of a guideline-based composite outcome assessment tool for asthma control.",
abstract = "BACKGROUND: A global definition of asthma control does not currently exist. The purpose of this study was to validate two new guideline-based composite measures of asthma control, defined as totally controlled (TC) asthma and well controlled (WC) asthma.METHODS: We used data from 3416 patients randomised and treated in the multi-centre Gaining Optimal Asthma controL (GOAL) study. The criteria comprising the asthma control measures were based on Global Initiative for Asthma/National Institutes of Health guidelines. This validation study examined the measurement properties of the asthma control measures using data from run-in, baseline, 12 and 52 weeks. Forced expiratory volume in 1 second (FEV1) and the Asthma Quality of Life Questionnaire (AQLQ) were used as the reference criteria in the validation analysis.RESULTS: Both measures had good discriminative ability showing significant differences in FEV1 and AQLQ scores between control classification both cross-sectionally and longitudinally (p < 0.001). Overall both of the composite measures accounted for more of the variance in FEV1 after 52 weeks than the individual components of each asthma control measure. Both of the reference criteria were independently related to each asthma control measure (p < 0.0001). The measures also had good predictive validity showing significant differences in FEV1 and AQLQ scores at 52 weeks by control classification at 12 weeks (p < 0.0001).CONCLUSION: The guideline-based composite asthma control measures of WC asthma and TC asthma have good psychometric properties and are both valid functional indices of disease control in asthma.",
author = "Sally Spencer and Bhabita Mayer and Bendall, {Late L} and Bateman, {Eric D}",
note = "{\textcopyright} 2007 Spencer et al; licensee BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.",
year = "2007",
month = mar,
day = "21",
doi = "10.1186/1465-9921-8-26",
language = "English",
volume = "8",
pages = "26--37",
journal = "Respiratory Research",
issn = "1465-993X",
publisher = "BioMed Central",
number = "1",

}

RIS

TY - JOUR

T1 - Validation of a guideline-based composite outcome assessment tool for asthma control.

AU - Spencer, Sally

AU - Mayer, Bhabita

AU - Bendall, Late L

AU - Bateman, Eric D

N1 - © 2007 Spencer et al; licensee BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

PY - 2007/3/21

Y1 - 2007/3/21

N2 - BACKGROUND: A global definition of asthma control does not currently exist. The purpose of this study was to validate two new guideline-based composite measures of asthma control, defined as totally controlled (TC) asthma and well controlled (WC) asthma.METHODS: We used data from 3416 patients randomised and treated in the multi-centre Gaining Optimal Asthma controL (GOAL) study. The criteria comprising the asthma control measures were based on Global Initiative for Asthma/National Institutes of Health guidelines. This validation study examined the measurement properties of the asthma control measures using data from run-in, baseline, 12 and 52 weeks. Forced expiratory volume in 1 second (FEV1) and the Asthma Quality of Life Questionnaire (AQLQ) were used as the reference criteria in the validation analysis.RESULTS: Both measures had good discriminative ability showing significant differences in FEV1 and AQLQ scores between control classification both cross-sectionally and longitudinally (p < 0.001). Overall both of the composite measures accounted for more of the variance in FEV1 after 52 weeks than the individual components of each asthma control measure. Both of the reference criteria were independently related to each asthma control measure (p < 0.0001). The measures also had good predictive validity showing significant differences in FEV1 and AQLQ scores at 52 weeks by control classification at 12 weeks (p < 0.0001).CONCLUSION: The guideline-based composite asthma control measures of WC asthma and TC asthma have good psychometric properties and are both valid functional indices of disease control in asthma.

AB - BACKGROUND: A global definition of asthma control does not currently exist. The purpose of this study was to validate two new guideline-based composite measures of asthma control, defined as totally controlled (TC) asthma and well controlled (WC) asthma.METHODS: We used data from 3416 patients randomised and treated in the multi-centre Gaining Optimal Asthma controL (GOAL) study. The criteria comprising the asthma control measures were based on Global Initiative for Asthma/National Institutes of Health guidelines. This validation study examined the measurement properties of the asthma control measures using data from run-in, baseline, 12 and 52 weeks. Forced expiratory volume in 1 second (FEV1) and the Asthma Quality of Life Questionnaire (AQLQ) were used as the reference criteria in the validation analysis.RESULTS: Both measures had good discriminative ability showing significant differences in FEV1 and AQLQ scores between control classification both cross-sectionally and longitudinally (p < 0.001). Overall both of the composite measures accounted for more of the variance in FEV1 after 52 weeks than the individual components of each asthma control measure. Both of the reference criteria were independently related to each asthma control measure (p < 0.0001). The measures also had good predictive validity showing significant differences in FEV1 and AQLQ scores at 52 weeks by control classification at 12 weeks (p < 0.0001).CONCLUSION: The guideline-based composite asthma control measures of WC asthma and TC asthma have good psychometric properties and are both valid functional indices of disease control in asthma.

U2 - 10.1186/1465-9921-8-26

DO - 10.1186/1465-9921-8-26

M3 - Journal article

VL - 8

SP - 26

EP - 37

JO - Respiratory Research

JF - Respiratory Research

SN - 1465-993X

IS - 1

M1 - 17376233

ER -