Home > Research > Publications & Outputs > Measurement of Space Charge Effects in the Micr...

Associated organisational unit

Electronic data

  • AAM

    Rights statement: This is an author-created, un-copyedited version of an article accepted for publication/published in Journal of Instrumentation. IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from it. The Version of Record is available online at doi:10.1088/1748-0221/15/12/P12037

    Accepted author manuscript, 2.18 MB, PDF document

    Available under license: CC BY-NC: Creative Commons Attribution-NonCommercial 4.0 International License

Links

Text available via DOI:

View graph of relations

Measurement of Space Charge Effects in the MicroBooNE LArTPC Using Cosmic Muons

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Published
Article numberP12037
<mark>Journal publication date</mark>31/12/2020
<mark>Journal</mark>Journal of Instrumentation
Volume15
Number of pages38
Publication StatusPublished
<mark>Original language</mark>English

Abstract

Large liquid argon time projection chambers (LArTPCs), especially those operating near the surface, are susceptible to space charge effects. In the context of LArTPCs, the space charge effect is the build-up of slow-moving positive ions in the detector primarily due to ionization from cosmic rays, leading to a distortion of the electric field within the detector. This effect leads to a displacement in the reconstructed position of signal ionization electrons in LArTPC detectors ("spatial distortions"), as well as to variations in the amount of electron-ion recombination experienced by ionization throughout the volume of the TPC. We present techniques that can be used to measure and correct for space charge effects in large LArTPCs by making use of cosmic muons, including the use of track pairs to unambiguously pin down spatial distortions in three dimensions. The performance of these calibration techniques are studied using both Monte Carlo simulation and MicroBooNE data, utilizing a UV laser system as a means to estimate the systematic bias associated with the calibration methodology.

Bibliographic note

This is an author-created, un-copyedited version of an article accepted for publication/published in Journal of Instrumentation. IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from it. The Version of Record is available online at doi:10.1088/1748-0221/15/12/P12037