Home > Research > Publications & Outputs > 3He/4He isotopic ratio measurements to below th...
View graph of relations

3He/4He isotopic ratio measurements to below the 10^-12 level

Research output: Contribution in Book/Report/Proceedings - With ISBN/ISSNChapter

Published

Standard

3He/4He isotopic ratio measurements to below the 10^-12 level. / Hendry, P. C.; McClintock, Peter V. E.
Proceedings of the 17th International Conference on Low Temperature Physics. ed. / U. Eckern; A. Schmid; W. Weber; H. Wuhl. Vol. Part I Amsterdam: North-Holland Physics Publishing, 1984. p. 417-418.

Research output: Contribution in Book/Report/Proceedings - With ISBN/ISSNChapter

Harvard

Hendry, PC & McClintock, PVE 1984, 3He/4He isotopic ratio measurements to below the 10^-12 level. in U Eckern, A Schmid, W Weber & H Wuhl (eds), Proceedings of the 17th International Conference on Low Temperature Physics. vol. Part I, North-Holland Physics Publishing, Amsterdam, pp. 417-418.

APA

Hendry, P. C., & McClintock, P. V. E. (1984). 3He/4He isotopic ratio measurements to below the 10^-12 level. In U. Eckern, A. Schmid, W. Weber, & H. Wuhl (Eds.), Proceedings of the 17th International Conference on Low Temperature Physics (Vol. Part I, pp. 417-418). North-Holland Physics Publishing.

Vancouver

Hendry PC, McClintock PVE. 3He/4He isotopic ratio measurements to below the 10^-12 level. In Eckern U, Schmid A, Weber W, Wuhl H, editors, Proceedings of the 17th International Conference on Low Temperature Physics. Vol. Part I. Amsterdam: North-Holland Physics Publishing. 1984. p. 417-418

Author

Hendry, P. C. ; McClintock, Peter V. E. / 3He/4He isotopic ratio measurements to below the 10^-12 level. Proceedings of the 17th International Conference on Low Temperature Physics. editor / U. Eckern ; A. Schmid ; W. Weber ; H. Wuhl. Vol. Part I Amsterdam : North-Holland Physics Publishing, 1984. pp. 417-418

Bibtex

@inbook{628b53f6cf474eefb77929ce97e978da,
title = "3He/4He isotopic ratio measurements to below the 10^-12 level",
abstract = "A miniature helium isotopic concentration cryostat is described. By means of this device, the 3He/4He ratio of a given sample of helium gas can be increased by a measurable factor of up to ca 400, thereby enhancing by the same factor the ultimate sensitivity of 3He/4He ratio determination by mass spectrometry.",
author = "Hendry, {P. C.} and McClintock, {Peter V. E.}",
note = "Proceedings of the 17th International Conference on Low Temperature Physics, Karlsruhe, 15-22 August 1984.",
year = "1984",
language = "English",
isbn = "0 444 86910 7",
volume = "Part I",
pages = "417--418",
editor = "U. Eckern and A. Schmid and W. Weber and H. Wuhl",
booktitle = "Proceedings of the 17th International Conference on Low Temperature Physics",
publisher = "North-Holland Physics Publishing",

}

RIS

TY - CHAP

T1 - 3He/4He isotopic ratio measurements to below the 10^-12 level

AU - Hendry, P. C.

AU - McClintock, Peter V. E.

N1 - Proceedings of the 17th International Conference on Low Temperature Physics, Karlsruhe, 15-22 August 1984.

PY - 1984

Y1 - 1984

N2 - A miniature helium isotopic concentration cryostat is described. By means of this device, the 3He/4He ratio of a given sample of helium gas can be increased by a measurable factor of up to ca 400, thereby enhancing by the same factor the ultimate sensitivity of 3He/4He ratio determination by mass spectrometry.

AB - A miniature helium isotopic concentration cryostat is described. By means of this device, the 3He/4He ratio of a given sample of helium gas can be increased by a measurable factor of up to ca 400, thereby enhancing by the same factor the ultimate sensitivity of 3He/4He ratio determination by mass spectrometry.

M3 - Chapter

SN - 0 444 86910 7

VL - Part I

SP - 417

EP - 418

BT - Proceedings of the 17th International Conference on Low Temperature Physics

A2 - Eckern, U.

A2 - Schmid, A.

A2 - Weber, W.

A2 - Wuhl, H.

PB - North-Holland Physics Publishing

CY - Amsterdam