Home > Research > Publications & Outputs > A Custom-Made Lower Limb Dynamometer for Assess...

Links

Text available via DOI:

View graph of relations

A Custom-Made Lower Limb Dynamometer for Assessing Ankle Joint Torque in Humans: Calibration and Measurement Procedures

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Published

Standard

A Custom-Made Lower Limb Dynamometer for Assessing Ankle Joint Torque in Humans: Calibration and Measurement Procedures. / Drăgoi, Iulia Iovanca; Popescu, Florina Georgeta; Petrița, Teodor et al.
In: Sensors, Vol. 22, No. 1, 135, 25.12.2021.

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Harvard

Drăgoi, II, Popescu, FG, Petrița, T, Tatu, RF, Bondor, CI, Tatu, C, Bowling, FL, Reeves, ND & Ionac, M 2021, 'A Custom-Made Lower Limb Dynamometer for Assessing Ankle Joint Torque in Humans: Calibration and Measurement Procedures', Sensors, vol. 22, no. 1, 135. https://doi.org/10.3390/s22010135

APA

Drăgoi, I. I., Popescu, F. G., Petrița, T., Tatu, R. F., Bondor, C. I., Tatu, C., Bowling, F. L., Reeves, N. D., & Ionac, M. (2021). A Custom-Made Lower Limb Dynamometer for Assessing Ankle Joint Torque in Humans: Calibration and Measurement Procedures. Sensors, 22(1), Article 135. https://doi.org/10.3390/s22010135

Vancouver

Drăgoi II, Popescu FG, Petrița T, Tatu RF, Bondor CI, Tatu C et al. A Custom-Made Lower Limb Dynamometer for Assessing Ankle Joint Torque in Humans: Calibration and Measurement Procedures. Sensors. 2021 Dec 25;22(1):135. doi: 10.3390/s22010135

Author

Drăgoi, Iulia Iovanca ; Popescu, Florina Georgeta ; Petrița, Teodor et al. / A Custom-Made Lower Limb Dynamometer for Assessing Ankle Joint Torque in Humans : Calibration and Measurement Procedures. In: Sensors. 2021 ; Vol. 22, No. 1.

Bibtex

@article{9426469cb6884d8d95673188b903134f,
title = "A Custom-Made Lower Limb Dynamometer for Assessing Ankle Joint Torque in Humans: Calibration and Measurement Procedures",
abstract = "Custom-made dynamometry was shown to objectively analyze human muscle strength around the ankle joint with accuracy, easy portability and low costs. This paper describes the full method of calibration and measurement setup and the measurement procedure when capturing ankle torque for establishing reliability of a portable custom-built electronic dynamometer. After considering the load cell offset voltage, the pivotal position was determined, and calibration with loads followed. Linear regression was used for calculating the proportionality constant between torque and measured voltage. Digital means were used for data collection and processing. Four healthy consenting participants were enrolled in the study. Three consecutive maximum voluntary isometric contractions of five seconds each were registered for both feet during plantar flexion/dorsiflexion, and ankle torque was then calculated for three ankle inclinations. A calibration procedure resulted, comprising determination of the pivotal axis and pedal constant. Using the obtained data, a measurement procedure was proposed. Obtained contraction time graphs led to easier filtering of the results. When calculating the interclass correlation, the portable apparatus demonstrated to be reliable when measuring ankle torque. When a custom-made dynamometer was used for capturing ankle torque, accuracy of the method was assured by a rigorous calibration and measurement protocol elaboration.",
author = "Dr{\u a}goi, {Iulia Iovanca} and Popescu, {Florina Georgeta} and Teodor Petrița and Tatu, {Romulus Fabian} and Bondor, {Cosmina Ioana} and Carmen Tatu and Bowling, {Frank L.} and Reeves, {Neil D.} and Mihai Ionac",
year = "2021",
month = dec,
day = "25",
doi = "10.3390/s22010135",
language = "English",
volume = "22",
journal = "Sensors",
issn = "1424-8220",
publisher = "Multidisciplinary Digital Publishing Institute (MDPI)",
number = "1",

}

RIS

TY - JOUR

T1 - A Custom-Made Lower Limb Dynamometer for Assessing Ankle Joint Torque in Humans

T2 - Calibration and Measurement Procedures

AU - Drăgoi, Iulia Iovanca

AU - Popescu, Florina Georgeta

AU - Petrița, Teodor

AU - Tatu, Romulus Fabian

AU - Bondor, Cosmina Ioana

AU - Tatu, Carmen

AU - Bowling, Frank L.

AU - Reeves, Neil D.

AU - Ionac, Mihai

PY - 2021/12/25

Y1 - 2021/12/25

N2 - Custom-made dynamometry was shown to objectively analyze human muscle strength around the ankle joint with accuracy, easy portability and low costs. This paper describes the full method of calibration and measurement setup and the measurement procedure when capturing ankle torque for establishing reliability of a portable custom-built electronic dynamometer. After considering the load cell offset voltage, the pivotal position was determined, and calibration with loads followed. Linear regression was used for calculating the proportionality constant between torque and measured voltage. Digital means were used for data collection and processing. Four healthy consenting participants were enrolled in the study. Three consecutive maximum voluntary isometric contractions of five seconds each were registered for both feet during plantar flexion/dorsiflexion, and ankle torque was then calculated for three ankle inclinations. A calibration procedure resulted, comprising determination of the pivotal axis and pedal constant. Using the obtained data, a measurement procedure was proposed. Obtained contraction time graphs led to easier filtering of the results. When calculating the interclass correlation, the portable apparatus demonstrated to be reliable when measuring ankle torque. When a custom-made dynamometer was used for capturing ankle torque, accuracy of the method was assured by a rigorous calibration and measurement protocol elaboration.

AB - Custom-made dynamometry was shown to objectively analyze human muscle strength around the ankle joint with accuracy, easy portability and low costs. This paper describes the full method of calibration and measurement setup and the measurement procedure when capturing ankle torque for establishing reliability of a portable custom-built electronic dynamometer. After considering the load cell offset voltage, the pivotal position was determined, and calibration with loads followed. Linear regression was used for calculating the proportionality constant between torque and measured voltage. Digital means were used for data collection and processing. Four healthy consenting participants were enrolled in the study. Three consecutive maximum voluntary isometric contractions of five seconds each were registered for both feet during plantar flexion/dorsiflexion, and ankle torque was then calculated for three ankle inclinations. A calibration procedure resulted, comprising determination of the pivotal axis and pedal constant. Using the obtained data, a measurement procedure was proposed. Obtained contraction time graphs led to easier filtering of the results. When calculating the interclass correlation, the portable apparatus demonstrated to be reliable when measuring ankle torque. When a custom-made dynamometer was used for capturing ankle torque, accuracy of the method was assured by a rigorous calibration and measurement protocol elaboration.

U2 - 10.3390/s22010135

DO - 10.3390/s22010135

M3 - Journal article

VL - 22

JO - Sensors

JF - Sensors

SN - 1424-8220

IS - 1

M1 - 135

ER -