T1 - An ISFET Sensor-Integrated Micromixer for pH Measurements
AU - Acar, Gizem
AU - Alijani, Hossein
AU - Kosar, Ali
AU - Yapici, Murat Kaya
PY - 2020/7/30
Y1 - 2020/7/30
N2 - This study reports the design and numerical modelling of a microfluidic mixer with an integrated ion-sensitive transistor (ISFET) for sensing of pH values. The valves in the microfluidic device allowed adjustment of the flow rate of each solution and different pH values for the mixture was achieved. At high flow rates around 1500μL/min, pH value of the solution could be controlled in the range of 3-12 with a response time on the order of seconds. The performance of the proposed micromixer in mixing diluted acid and base solutions was simulated using COMSOL Multiphysics software. Current-voltage characteristics were obtained by using silicon dioxide (SiO 2 ) and tantalum pentoxide (Ta 2 O 5 ) as the gate dielectric, and pH sensitivities were compared. Upon optimization of the micromixer and sensor, a numerical model, which included both components was developed by setting the flow rates of diluted acid and base solutions. This enabled active control on the pH of the mixed solution, which was exposed to the ISFET pH sensor at the outlet of the micromixer, where the ISFET sensor continuously monitored the pH of the solution with a separate readout circuit.
AB - This study reports the design and numerical modelling of a microfluidic mixer with an integrated ion-sensitive transistor (ISFET) for sensing of pH values. The valves in the microfluidic device allowed adjustment of the flow rate of each solution and different pH values for the mixture was achieved. At high flow rates around 1500μL/min, pH value of the solution could be controlled in the range of 3-12 with a response time on the order of seconds. The performance of the proposed micromixer in mixing diluted acid and base solutions was simulated using COMSOL Multiphysics software. Current-voltage characteristics were obtained by using silicon dioxide (SiO 2 ) and tantalum pentoxide (Ta 2 O 5 ) as the gate dielectric, and pH sensitivities were compared. Upon optimization of the micromixer and sensor, a numerical model, which included both components was developed by setting the flow rates of diluted acid and base solutions. This enabled active control on the pH of the mixed solution, which was exposed to the ISFET pH sensor at the outlet of the micromixer, where the ISFET sensor continuously monitored the pH of the solution with a separate readout circuit.
U2 - 10.1109/eurosime48426.2020.9152729
DO - 10.1109/eurosime48426.2020.9152729
M3 - Conference contribution/Paper
SN - 978-1-7281-6050-4
BT - 2020 21st International Conference on Thermal, Mechanical and Multi-Physics Simulation and Experiments in Microelectronics and Microsystems (EuroSimE)
PB - IEEE