Home > Research > Publications & Outputs > Angular dependent measurement of electron-ion r...

Links

Text available via DOI:

View graph of relations

Angular dependent measurement of electron-ion recombination in liquid argon for ionization calorimetry in the ICARUS liquid argon time projection chamber

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Published

Standard

Angular dependent measurement of electron-ion recombination in liquid argon for ionization calorimetry in the ICARUS liquid argon time projection chamber. / The ICARUS collaboration.
In: Journal of Instrumentation, Vol. 20, No. 01, P01033, 31.01.2025.

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Harvard

APA

Vancouver

The ICARUS collaboration. Angular dependent measurement of electron-ion recombination in liquid argon for ionization calorimetry in the ICARUS liquid argon time projection chamber. Journal of Instrumentation. 2025 Jan 31;20(01):P01033. doi: 10.1088/1748-0221/20/01/p01033

Author

Bibtex

@article{7a93472a781843978d9689554fede9bf,
title = "Angular dependent measurement of electron-ion recombination in liquid argon for ionization calorimetry in the ICARUS liquid argon time projection chamber",
abstract = "This paper reports on a measurement of electron-ion recombination in liquid argon in the ICARUS liquid argon time projection chamber (LArTPC). A clear dependence of recombination on the angle of the ionizing particle track relative to the drift electric field is observed. An ellipsoid modified box (EMB) model of recombination describes the data across all measured angles. These measurements are used for the calorimetric energy scale calibration of the ICARUS TPC, which is also presented. The impact of the EMB model is studied on calorimetric particle identification, as well as muon and proton energy measurements. Accounting for the angular dependence in EMB recombination improves the accuracy and precision of these measurements.",
keywords = "Calorimeters, Neutrino detectors, Time projection chambers, dE/dx detectors",
author = "{The ICARUS collaboration} and P. Abratenko and N. Abrego-Martinez and A. Aduszkiewicz and F. Akbar and {Aliaga Soplin}, L. and {Artero Pons}, M. and J. Asaadi and W.F. Badgett and B. Baibussinov and B. Behera and V. Bellini and R. Benocci and J. Berger and S. Berkman and S. Bertolucci and M. Betancourt and M. Bonesini and T. Boone and B. Bottino and A. Braggiotti and D. Brailsford and S.J. Brice and V. Brio and C. Brizzolari and H.S. Budd and A. Campani and A. Campos and D. Carber and M. Carneiro and {Caro Terrazas}, I. and H. Carranza and S. Dolan and A. Ferrari and F.G. Garcia and W. Gu and B. Howard and C. James and J.S. Kim and Y. Li and M. Murphy and S. Saha and J. Smith and J. Stewart and Z. Williams and R.J. Wilson and P. Wilson and A. Wood and H. Yu and J. Yu and C. Zhang",
year = "2025",
month = jan,
day = "31",
doi = "10.1088/1748-0221/20/01/p01033",
language = "English",
volume = "20",
journal = "Journal of Instrumentation",
issn = "1748-0221",
publisher = "Institute of Physics Publishing",
number = "01",

}

RIS

TY - JOUR

T1 - Angular dependent measurement of electron-ion recombination in liquid argon for ionization calorimetry in the ICARUS liquid argon time projection chamber

AU - The ICARUS collaboration

AU - Abratenko, P.

AU - Abrego-Martinez, N.

AU - Aduszkiewicz, A.

AU - Akbar, F.

AU - Aliaga Soplin, L.

AU - Artero Pons, M.

AU - Asaadi, J.

AU - Badgett, W.F.

AU - Baibussinov, B.

AU - Behera, B.

AU - Bellini, V.

AU - Benocci, R.

AU - Berger, J.

AU - Berkman, S.

AU - Bertolucci, S.

AU - Betancourt, M.

AU - Bonesini, M.

AU - Boone, T.

AU - Bottino, B.

AU - Braggiotti, A.

AU - Brailsford, D.

AU - Brice, S.J.

AU - Brio, V.

AU - Brizzolari, C.

AU - Budd, H.S.

AU - Campani, A.

AU - Campos, A.

AU - Carber, D.

AU - Carneiro, M.

AU - Caro Terrazas, I.

AU - Carranza, H.

AU - Dolan, S.

AU - Ferrari, A.

AU - Garcia, F.G.

AU - Gu, W.

AU - Howard, B.

AU - James, C.

AU - Kim, J.S.

AU - Li, Y.

AU - Murphy, M.

AU - Saha, S.

AU - Smith, J.

AU - Stewart, J.

AU - Williams, Z.

AU - Wilson, R.J.

AU - Wilson, P.

AU - Wood, A.

AU - Yu, H.

AU - Yu, J.

AU - Zhang, C.

PY - 2025/1/31

Y1 - 2025/1/31

N2 - This paper reports on a measurement of electron-ion recombination in liquid argon in the ICARUS liquid argon time projection chamber (LArTPC). A clear dependence of recombination on the angle of the ionizing particle track relative to the drift electric field is observed. An ellipsoid modified box (EMB) model of recombination describes the data across all measured angles. These measurements are used for the calorimetric energy scale calibration of the ICARUS TPC, which is also presented. The impact of the EMB model is studied on calorimetric particle identification, as well as muon and proton energy measurements. Accounting for the angular dependence in EMB recombination improves the accuracy and precision of these measurements.

AB - This paper reports on a measurement of electron-ion recombination in liquid argon in the ICARUS liquid argon time projection chamber (LArTPC). A clear dependence of recombination on the angle of the ionizing particle track relative to the drift electric field is observed. An ellipsoid modified box (EMB) model of recombination describes the data across all measured angles. These measurements are used for the calorimetric energy scale calibration of the ICARUS TPC, which is also presented. The impact of the EMB model is studied on calorimetric particle identification, as well as muon and proton energy measurements. Accounting for the angular dependence in EMB recombination improves the accuracy and precision of these measurements.

KW - Calorimeters

KW - Neutrino detectors

KW - Time projection chambers

KW - dE/dx detectors

U2 - 10.1088/1748-0221/20/01/p01033

DO - 10.1088/1748-0221/20/01/p01033

M3 - Journal article

VL - 20

JO - Journal of Instrumentation

JF - Journal of Instrumentation

SN - 1748-0221

IS - 01

M1 - P01033

ER -