Home > Research > Publications & Outputs > He-4 isotopic purification in continuous flow.
View graph of relations

He-4 isotopic purification in continuous flow.

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Published

Standard

He-4 isotopic purification in continuous flow. / Hendry, P. C.; McClintock, Peter V. E.
In: Cryogenics, Vol. 25, No. 9, 09.1985, p. 526-527.

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Harvard

APA

Vancouver

Hendry PC, McClintock PVE. He-4 isotopic purification in continuous flow. Cryogenics. 1985 Sept;25(9):526-527. doi: 10.1016/0011-2275(85)90077-3

Author

Bibtex

@article{a943d55db1344809a3e6f2fec1d7d34f,
title = "He-4 isotopic purification in continuous flow.",
abstract = "We report the successful operation of a 4He isotopic purifier capable of producing helium with a 3He/4He ratio of < 10^-12 on a continuous basis.",
author = "Hendry, {P. C.} and McClintock, {Peter V. E.}",
year = "1985",
month = sep,
doi = "10.1016/0011-2275(85)90077-3",
language = "English",
volume = "25",
pages = "526--527",
journal = "Cryogenics",
issn = "0011-2275",
publisher = "Elsevier Limited",
number = "9",

}

RIS

TY - JOUR

T1 - He-4 isotopic purification in continuous flow.

AU - Hendry, P. C.

AU - McClintock, Peter V. E.

PY - 1985/9

Y1 - 1985/9

N2 - We report the successful operation of a 4He isotopic purifier capable of producing helium with a 3He/4He ratio of < 10^-12 on a continuous basis.

AB - We report the successful operation of a 4He isotopic purifier capable of producing helium with a 3He/4He ratio of < 10^-12 on a continuous basis.

U2 - 10.1016/0011-2275(85)90077-3

DO - 10.1016/0011-2275(85)90077-3

M3 - Journal article

VL - 25

SP - 526

EP - 527

JO - Cryogenics

JF - Cryogenics

SN - 0011-2275

IS - 9

ER -