Home > Research > Publications & Outputs > The optical alignment system of the ZEUS microv...
View graph of relations

The optical alignment system of the ZEUS microvertex detector

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Published

Standard

The optical alignment system of the ZEUS microvertex detector. / Korcsak-Gorzo, K.; Grzelak, G.; Oliver, K. et al.
In: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 580, No. 3, 11.10.2007, p. 1227-1242.

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Harvard

Korcsak-Gorzo, K, Grzelak, G, Oliver, K, Dawson, M, Devenish, R, Ferrando, J, Matsushita, T, Shield, P & Walczak, R 2007, 'The optical alignment system of the ZEUS microvertex detector', Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, vol. 580, no. 3, pp. 1227-1242. https://doi.org/10.1016/j.nima.2007.06.046

APA

Korcsak-Gorzo, K., Grzelak, G., Oliver, K., Dawson, M., Devenish, R., Ferrando, J., Matsushita, T., Shield, P., & Walczak, R. (2007). The optical alignment system of the ZEUS microvertex detector. Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 580(3), 1227-1242. https://doi.org/10.1016/j.nima.2007.06.046

Vancouver

Korcsak-Gorzo K, Grzelak G, Oliver K, Dawson M, Devenish R, Ferrando J et al. The optical alignment system of the ZEUS microvertex detector. Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 2007 Oct 11;580(3):1227-1242. doi: 10.1016/j.nima.2007.06.046

Author

Korcsak-Gorzo, K. ; Grzelak, G. ; Oliver, K. et al. / The optical alignment system of the ZEUS microvertex detector. In: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 2007 ; Vol. 580, No. 3. pp. 1227-1242.

Bibtex

@article{da52b672983f48a4a333ab8843cd6331,
title = "The optical alignment system of the ZEUS microvertex detector",
abstract = "The laser alignment system of the ZEUS microvertex detector is described. The detector was installed in 2001 as part of an upgrade programme in preparation for the second phase of electron-proton physics at the HERA collider. The alignment system monitors the position of the vertex detector support structure with respect to the central tracking detector using semi-transparent amorphous-silicon sensors and diode lasers. The system is fully integrated into the general environmental monitoring of the ZEUS detector and data has been collected over a period of 5 years. The primary aim of defining periods of stability for track-based alignment has been achieved and the system is able to measure movements of the support structure to a precision around 10 μ m.",
keywords = "Alignment, Laser, Semi-transparent sensors, Vertex detector",
author = "K. Korcsak-Gorzo and G. Grzelak and K. Oliver and M. Dawson and R. Devenish and J. Ferrando and T. Matsushita and P. Shield and R. Walczak",
year = "2007",
month = oct,
day = "11",
doi = "10.1016/j.nima.2007.06.046",
language = "English",
volume = "580",
pages = "1227--1242",
journal = "Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment",
issn = "0168-9002",
publisher = "Elsevier Science B.V.",
number = "3",

}

RIS

TY - JOUR

T1 - The optical alignment system of the ZEUS microvertex detector

AU - Korcsak-Gorzo, K.

AU - Grzelak, G.

AU - Oliver, K.

AU - Dawson, M.

AU - Devenish, R.

AU - Ferrando, J.

AU - Matsushita, T.

AU - Shield, P.

AU - Walczak, R.

PY - 2007/10/11

Y1 - 2007/10/11

N2 - The laser alignment system of the ZEUS microvertex detector is described. The detector was installed in 2001 as part of an upgrade programme in preparation for the second phase of electron-proton physics at the HERA collider. The alignment system monitors the position of the vertex detector support structure with respect to the central tracking detector using semi-transparent amorphous-silicon sensors and diode lasers. The system is fully integrated into the general environmental monitoring of the ZEUS detector and data has been collected over a period of 5 years. The primary aim of defining periods of stability for track-based alignment has been achieved and the system is able to measure movements of the support structure to a precision around 10 μ m.

AB - The laser alignment system of the ZEUS microvertex detector is described. The detector was installed in 2001 as part of an upgrade programme in preparation for the second phase of electron-proton physics at the HERA collider. The alignment system monitors the position of the vertex detector support structure with respect to the central tracking detector using semi-transparent amorphous-silicon sensors and diode lasers. The system is fully integrated into the general environmental monitoring of the ZEUS detector and data has been collected over a period of 5 years. The primary aim of defining periods of stability for track-based alignment has been achieved and the system is able to measure movements of the support structure to a precision around 10 μ m.

KW - Alignment

KW - Laser

KW - Semi-transparent sensors

KW - Vertex detector

U2 - 10.1016/j.nima.2007.06.046

DO - 10.1016/j.nima.2007.06.046

M3 - Journal article

AN - SCOPUS:34548703109

VL - 580

SP - 1227

EP - 1242

JO - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

SN - 0168-9002

IS - 3

ER -