Home > Research > Publications & Outputs > Measurement of [11C]CO2 in exhaled air with a p...

Associated organisational unit

View graph of relations

Measurement of [11C]CO2 in exhaled air with a positron-sensitive single-wire proportional counter after i.v. injection of [11C] acetate

Research output: Contribution in Book/Report/Proceedings - With ISBN/ISSNConference contribution/Paperpeer-review

Published

Standard

Measurement of [11C]CO2 in exhaled air with a positron-sensitive single-wire proportional counter after i.v. injection of [11C] acetate. / Sipila, H.T.; Heselius, S.-J.; Kalliokoski, Matti et al.
2011 IEEE Nuclear Science Symposium and Medical Imaging Conference. New York: IEEE, 2011. p. 2397-2399.

Research output: Contribution in Book/Report/Proceedings - With ISBN/ISSNConference contribution/Paperpeer-review

Harvard

Sipila, HT, Heselius, S-J, Kalliokoski, M, Kemppainen, J, Minn, H, Tolvanen, T & Roivainen, A 2011, Measurement of [11C]CO2 in exhaled air with a positron-sensitive single-wire proportional counter after i.v. injection of [11C] acetate. in 2011 IEEE Nuclear Science Symposium and Medical Imaging Conference. IEEE, New York, pp. 2397-2399, IEEE Nuclear Science Symposium/Medical Imaging Conference (NSS/MIC)/18th International Workshop on Room-Temperature Semiconductor X-Ray and Gamma-Ray Detectors, Valencia, 23/10/11. https://doi.org/10.1109/NSSMIC.2011.6152653

APA

Sipila, H. T., Heselius, S.-J., Kalliokoski, M., Kemppainen, J., Minn, H., Tolvanen, T., & Roivainen, A. (2011). Measurement of [11C]CO2 in exhaled air with a positron-sensitive single-wire proportional counter after i.v. injection of [11C] acetate. In 2011 IEEE Nuclear Science Symposium and Medical Imaging Conference (pp. 2397-2399). IEEE. https://doi.org/10.1109/NSSMIC.2011.6152653

Vancouver

Sipila HT, Heselius SJ, Kalliokoski M, Kemppainen J, Minn H, Tolvanen T et al. Measurement of [11C]CO2 in exhaled air with a positron-sensitive single-wire proportional counter after i.v. injection of [11C] acetate. In 2011 IEEE Nuclear Science Symposium and Medical Imaging Conference. New York: IEEE. 2011. p. 2397-2399 doi: 10.1109/NSSMIC.2011.6152653

Author

Sipila, H.T. ; Heselius, S.-J. ; Kalliokoski, Matti et al. / Measurement of [11C]CO2 in exhaled air with a positron-sensitive single-wire proportional counter after i.v. injection of [11C] acetate. 2011 IEEE Nuclear Science Symposium and Medical Imaging Conference. New York : IEEE, 2011. pp. 2397-2399

Bibtex

@inproceedings{0a4d67dd49a24b5bbbcfcde08722c564,
title = "Measurement of [11C]CO2 in exhaled air with a positron-sensitive single-wire proportional counter after i.v. injection of [11C] acetate",
abstract = "A positron-sensitive, large window single-wire proportional counter was used for measurements of [11C]CO2 in exhaled air after i.v. injection of [11C] acetate. The performance of the proportional counter was studied using Geant4 and Garfield simulation tools as well as experimentally by injections of known amounts of radioactive gas into measuring volume. The proportional counter was found to be sensitive enough for measuring the low concentrations of [11C]CO2 in the air exhaled by patients after i.v. injection of an 11C-labelled radiopharmaceutical. The limit of detection was 200 Bq/L for [11C]CO2.",
author = "H.T. Sipila and S.-J. Heselius and Matti Kalliokoski and J Kemppainen and H Minn and T Tolvanen and A Roivainen",
year = "2011",
doi = "10.1109/NSSMIC.2011.6152653",
language = "English",
isbn = "978-1-4673-0118-3",
pages = "2397--2399",
booktitle = "2011 IEEE Nuclear Science Symposium and Medical Imaging Conference",
publisher = "IEEE",
note = "IEEE Nuclear Science Symposium/Medical Imaging Conference (NSS/MIC)/18th International Workshop on Room-Temperature Semiconductor X-Ray and Gamma-Ray Detectors ; Conference date: 23-10-2011 Through 29-10-2011",

}

RIS

TY - GEN

T1 - Measurement of [11C]CO2 in exhaled air with a positron-sensitive single-wire proportional counter after i.v. injection of [11C] acetate

AU - Sipila, H.T.

AU - Heselius, S.-J.

AU - Kalliokoski, Matti

AU - Kemppainen, J

AU - Minn, H

AU - Tolvanen, T

AU - Roivainen, A

PY - 2011

Y1 - 2011

N2 - A positron-sensitive, large window single-wire proportional counter was used for measurements of [11C]CO2 in exhaled air after i.v. injection of [11C] acetate. The performance of the proportional counter was studied using Geant4 and Garfield simulation tools as well as experimentally by injections of known amounts of radioactive gas into measuring volume. The proportional counter was found to be sensitive enough for measuring the low concentrations of [11C]CO2 in the air exhaled by patients after i.v. injection of an 11C-labelled radiopharmaceutical. The limit of detection was 200 Bq/L for [11C]CO2.

AB - A positron-sensitive, large window single-wire proportional counter was used for measurements of [11C]CO2 in exhaled air after i.v. injection of [11C] acetate. The performance of the proportional counter was studied using Geant4 and Garfield simulation tools as well as experimentally by injections of known amounts of radioactive gas into measuring volume. The proportional counter was found to be sensitive enough for measuring the low concentrations of [11C]CO2 in the air exhaled by patients after i.v. injection of an 11C-labelled radiopharmaceutical. The limit of detection was 200 Bq/L for [11C]CO2.

U2 - 10.1109/NSSMIC.2011.6152653

DO - 10.1109/NSSMIC.2011.6152653

M3 - Conference contribution/Paper

SN - 978-1-4673-0118-3

SP - 2397

EP - 2399

BT - 2011 IEEE Nuclear Science Symposium and Medical Imaging Conference

PB - IEEE

CY - New York

T2 - IEEE Nuclear Science Symposium/Medical Imaging Conference (NSS/MIC)/18th International Workshop on Room-Temperature Semiconductor X-Ray and Gamma-Ray Detectors

Y2 - 23 October 2011 through 29 October 2011

ER -