Home > Research > Publications & Outputs > Observation of Radon Mitigation in MicroBooNE b...

Associated organisational unit

Electronic data

  • 2203.10147

    Rights statement: This is an author-created, un-copyedited version of an article accepted for publication/published in Journal of Instrumentation. IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from it. The Version of Record is available online at doi:10.1088/1748-0221/17/11/P11022

    Accepted author manuscript, 1.08 MB, PDF document

    Available under license: CC BY: Creative Commons Attribution 4.0 International License

Links

Text available via DOI:

View graph of relations

Observation of Radon Mitigation in MicroBooNE by a Liquid Argon Filtration System

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Published

Standard

Observation of Radon Mitigation in MicroBooNE by a Liquid Argon Filtration System. / MicroBooNE Collaboration ; Blake, A.; Devitt, A. et al.
In: Journal of Instrumentation, Vol. 17, No. 11, P11022, 16.11.2022.

Research output: Contribution to Journal/MagazineJournal articlepeer-review

Harvard

APA

Vancouver

MicroBooNE Collaboration, Blake A, Devitt A, Nowak J, Patel N, Thorpe C. Observation of Radon Mitigation in MicroBooNE by a Liquid Argon Filtration System. Journal of Instrumentation. 2022 Nov 16;17(11):P11022. doi: 10.1088/1748-0221/17/11/P11022

Author

MicroBooNE Collaboration ; Blake, A. ; Devitt, A. et al. / Observation of Radon Mitigation in MicroBooNE by a Liquid Argon Filtration System. In: Journal of Instrumentation. 2022 ; Vol. 17, No. 11.

Bibtex

@article{26739f5f7b214a3a969e770a1159cf6d,
title = "Observation of Radon Mitigation in MicroBooNE by a Liquid Argon Filtration System",
abstract = "The MicroBooNE liquid argon time projection chamber (LArTPC) maintains a high level of liquid argon purity through the use of a filtration system that removes electronegative contaminants in continuously-circulated liquid, recondensed boil off, and externally supplied argon gas. We use the MicroBooNE LArTPC to reconstruct MeV-scale radiological decays. Using this technique we measure the liquid argon filtration system's efficacy at removing radon. This is studied by placing a 500 kBq $^{222}$Rn source upstream of the filters and searching for a time-dependent increase in the number of radiological decays in the LArTPC. The liquid argon filtration system was able to remove greater than 99.999% of the radon injected into the system. Furthermore, a radiological survey of the filters found that the copper-based filter material was the primary medium that removed the $^{222}$Rn. This is the first observation of radon mitigation in liquid argon with a large-scale copper-based filter and could offer a radon mitigation solution for future large LArTPCs. ",
keywords = "physics.ins-det, hep-ex",
author = "{MicroBooNE Collaboration} and P. Abratenko and J. Anthony and L. Arellano and J. Asaadi and A. Ashkenazi and S. Balasubramanian and B. Baller and G. Barr and J. Barrow and V. Basque and L. Bathe-Peters and Rodrigues, {O. Benevides} and S. Berkman and A. Bhanderi and A. Bhat and M. Bhattacharya and M. Bishai and A. Blake and T. Bolton and Book, {J. Y.} and L. Camilleri and D. Caratelli and Terrazas, {I. Caro} and F. Cavanna and G. Cerati and D. Cianci and Conrad, {J. M.} and M. Convery and L. Cooper-Troendle and Crespo-Anadon, {J. I.} and Tutto, {M. Del} and Dennis, {S. R.} and P. Detje and A. Devitt and R. Diurba and R. Dorrill and K. Duffy and S. Dytman and B. Eberly and A. Ereditato and R. Fine and Aguirre, {G. A. Fiorentini} and Fitzpatrick, {R. S.} and Fleming, {B. T.} and N. Foppiani and D. Franco and J. Nowak and N. Patel and C. Thorpe",
note = "This is an author-created, un-copyedited version of an article accepted for publication/published in Journal of Instrumentation. IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from it. The Version of Record is available online at doi:10.1088/1748-0221/17/11/P11022",
year = "2022",
month = nov,
day = "16",
doi = "10.1088/1748-0221/17/11/P11022",
language = "English",
volume = "17",
journal = "Journal of Instrumentation",
issn = "1748-0221",
publisher = "Institute of Physics Publishing",
number = "11",

}

RIS

TY - JOUR

T1 - Observation of Radon Mitigation in MicroBooNE by a Liquid Argon Filtration System

AU - MicroBooNE Collaboration

AU - Abratenko, P.

AU - Anthony, J.

AU - Arellano, L.

AU - Asaadi, J.

AU - Ashkenazi, A.

AU - Balasubramanian, S.

AU - Baller, B.

AU - Barr, G.

AU - Barrow, J.

AU - Basque, V.

AU - Bathe-Peters, L.

AU - Rodrigues, O. Benevides

AU - Berkman, S.

AU - Bhanderi, A.

AU - Bhat, A.

AU - Bhattacharya, M.

AU - Bishai, M.

AU - Blake, A.

AU - Bolton, T.

AU - Book, J. Y.

AU - Camilleri, L.

AU - Caratelli, D.

AU - Terrazas, I. Caro

AU - Cavanna, F.

AU - Cerati, G.

AU - Cianci, D.

AU - Conrad, J. M.

AU - Convery, M.

AU - Cooper-Troendle, L.

AU - Crespo-Anadon, J. I.

AU - Tutto, M. Del

AU - Dennis, S. R.

AU - Detje, P.

AU - Devitt, A.

AU - Diurba, R.

AU - Dorrill, R.

AU - Duffy, K.

AU - Dytman, S.

AU - Eberly, B.

AU - Ereditato, A.

AU - Fine, R.

AU - Aguirre, G. A. Fiorentini

AU - Fitzpatrick, R. S.

AU - Fleming, B. T.

AU - Foppiani, N.

AU - Franco, D.

AU - Nowak, J.

AU - Patel, N.

AU - Thorpe, C.

N1 - This is an author-created, un-copyedited version of an article accepted for publication/published in Journal of Instrumentation. IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from it. The Version of Record is available online at doi:10.1088/1748-0221/17/11/P11022

PY - 2022/11/16

Y1 - 2022/11/16

N2 - The MicroBooNE liquid argon time projection chamber (LArTPC) maintains a high level of liquid argon purity through the use of a filtration system that removes electronegative contaminants in continuously-circulated liquid, recondensed boil off, and externally supplied argon gas. We use the MicroBooNE LArTPC to reconstruct MeV-scale radiological decays. Using this technique we measure the liquid argon filtration system's efficacy at removing radon. This is studied by placing a 500 kBq $^{222}$Rn source upstream of the filters and searching for a time-dependent increase in the number of radiological decays in the LArTPC. The liquid argon filtration system was able to remove greater than 99.999% of the radon injected into the system. Furthermore, a radiological survey of the filters found that the copper-based filter material was the primary medium that removed the $^{222}$Rn. This is the first observation of radon mitigation in liquid argon with a large-scale copper-based filter and could offer a radon mitigation solution for future large LArTPCs.

AB - The MicroBooNE liquid argon time projection chamber (LArTPC) maintains a high level of liquid argon purity through the use of a filtration system that removes electronegative contaminants in continuously-circulated liquid, recondensed boil off, and externally supplied argon gas. We use the MicroBooNE LArTPC to reconstruct MeV-scale radiological decays. Using this technique we measure the liquid argon filtration system's efficacy at removing radon. This is studied by placing a 500 kBq $^{222}$Rn source upstream of the filters and searching for a time-dependent increase in the number of radiological decays in the LArTPC. The liquid argon filtration system was able to remove greater than 99.999% of the radon injected into the system. Furthermore, a radiological survey of the filters found that the copper-based filter material was the primary medium that removed the $^{222}$Rn. This is the first observation of radon mitigation in liquid argon with a large-scale copper-based filter and could offer a radon mitigation solution for future large LArTPCs.

KW - physics.ins-det

KW - hep-ex

U2 - 10.1088/1748-0221/17/11/P11022

DO - 10.1088/1748-0221/17/11/P11022

M3 - Journal article

VL - 17

JO - Journal of Instrumentation

JF - Journal of Instrumentation

SN - 1748-0221

IS - 11

M1 - P11022